• Title/Summary/Keyword: Joint Loading

Search Result 767, Processing Time 0.024 seconds

Dynamic Analysis of Inclined Piles and Countermeasures against their Vulnerability (경사말뚝의 동적거동과 내진성능 향상을 위한 실험적 고찰)

  • 김재홍;황재익;김성렬;김명모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.107-114
    • /
    • 2001
  • When group pile supporting structures are to be subjected to large lateral loads, generally, hatter piles are used in group pile with vertical piles. It is well known that batter piles resist lateral static loads which are acted upon the piles as axial farces quite well but, they show a poor performance under seismic loads. However, it is not yet known how the batter piles behave under dynamic loading and how to strengthen the batter piles to improve the seismic performance. Shaking table tests were performed to investigate the seismic behavior of the batter pile and to bring up the countermeasures to improve the seismic performance. As the result of the shaking table tests, batter piles failed due to not only the excessive increase of compressive force near the pile head but also that of tensile force. In case that the pile head was connected with pile cap by rubber joint, the max. acceleration at the pile cap was reduced due to the high damping ratio of rubber and the max. moment and max. axial farce at the pile head was decreased remarkably. When the inclinations(V:H) of the batter pile were 8:3 and 8:4, max. moment, max. shear force, and max. axial farce were reduced notably and max. acceleration and max. displacement at the pile cap was diminished, too.

  • PDF

Detection of Defects in Composite Structures by using ESPI (ESPI를 이용한 복합재료 구조물의 결함 검출)

  • Kim, Kyung-Suk;Cheong, Seong-Kyun;Kang, Jin-Shik;Chang, Ho-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.299-306
    • /
    • 2001
  • In this paper, artificial and real defects(delamination and debond) in composite structures were detected by using ESPI system. Three types of specimens, that is, composite laminates, honeycomb structures, and adhesive joints, were used to study the applicability of ESPI to composite structures. To detect defects in specimens, we selected thermal loading method that can easily induce the surface deformation of specimen. Experimental results show that defects in composite structures could be easily detected by ESPI. Moreover, it shows that ESPI could be usefully applied to the detection of defects in various composite structures.

  • PDF

Tensile Behavior of CFT Column-to-H beam Connections with External T-shaped Stiffeners (T-스티프너 보강 콘크리트충전 각형강관 기둥-H형강 보 접합부의 인장거동)

  • Kang, Chang Hoon;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.121-130
    • /
    • 2002
  • This paper presents the tensile behavior of a Concrete-Filled Square Steel Tubular (CFT) column to H-beam welded connections. These connections were externally reinforced with T-shaped stiffeners at the junction of CFT column and beam. The tensile loading tests of eighteen tee-joint connections and finite element analysis using ANSYS were carried out. The main parameters of tests are as follows: 1) the thickness of Square Steel Tubular Column : 6 mm, 9 mm, 2) the strength ratios of tensile strength of horizontal stiffeners to tensile strength of beam flange : 70 %, 100 %, 150 %, 3) the strength ratios of shear strength of vertical stiffeners to tensile strength of beam flange : 80 %, 115 %, 160 %. The results of the tests demonstrate that overall behavior and failure modes of all the specimens are governed mainly by the horizontal stiffeners rather than the vertical stiffeners, and the vertical stiffener played only a role in transferring load introduced from beam to column.

A Comparison Study for the Fatigue Behavior of H/T and T/S Bolt Friction Joint (H/T 와 T/S 볼트 마찰이음의 피로거동 비교·검토)

  • JUN, Je Sang;WOO, Sang Ik;LEE, Seong Heang;JUNG, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.139-150
    • /
    • 1996
  • H/T(High Tension) bolt is generally being used in joining the members of steel structure. It has some difficulties in management such as an adequate fastening force and a selection of proper instrument for fastening. T/S(Torque Shear Type High Tension) bolt which is more convenient and easier than H/T bolt in quality control has recently been developed. T/S bolts are produced and widely used these days in domestic, but those have not a detail regulation for their on. Those are only being used according to the specification for the H/T bolts. In this study, we tried to confirm the soundness of T/S bolts by the fatigue test of the modified specimens. First, we measured the reduction rate of the initial axial force with time at bolts. Second, we investigated the slip forces of bolts when the test specimen is loaded in tension. Third, we implemented the fatigue tests. During the test, we measured the variation of the axial forces of bolts under the cyclic loading. Finally, we compared and analyzed the fatigue behavior of H/T and T/S bolt, by S-N curve diagrams that are obtained in this study.

  • PDF

Research on anti-seismic property of new end plate bolt connections - Wave web girder-column joint

  • Jiang, Haotian;Li, Qingning;Yan, Lei;Han, Chun;Lu, Wei;Jiang, Weishan
    • Steel and Composite Structures
    • /
    • v.22 no.1
    • /
    • pp.45-61
    • /
    • 2016
  • The domestic and foreign scholars conducted many studies on mechanical properties of wave web steel beam and high-strength spiral stirrups confined concrete columns. Based on the previous research work, studies were conducted on the anti-seismic property of the end plate bolt connected wave web steel beam and high-strength spiral stirrups confined concrete column nodes applied with pre-tightening force. Four full-size node test models in two groups were designed for low-cycle repeated loading quasi-static test. Through observation of the stress, distortion, failure process and failure mode of node models, analysis was made on its load-carrying capacity, deformation performance and energy dissipation capacity, and the reliability of the new node was verified. The results showed that: under action of the beam-end stiffener, the plastic hinges on the end of wave web steel beam are displaced outward and played its role of energy dissipation capacity. The study results provided reliable theoretical basis for the engineering application of the new types of nodes.

Constant amplitude fatigue test of high strength bolts in grid structures with bolt-sphere joints

  • Yang, Xu;Lei, Honggang
    • Steel and Composite Structures
    • /
    • v.25 no.5
    • /
    • pp.571-579
    • /
    • 2017
  • The grid structure with bolt-sphere joints is widely adopted by industrial plants with suspending crane. The alternating reciprocating action of the suspending crane will cause fatigue problems of the grid structure with bolt-sphere joints with respect to the rod, the cone, the sealing plate, the bolt ball and the high strength bolt; while the fatigue of the high strength bolt is the key issue of fatigue failure. Based on efficient and smooth loading equipment with the AMSLER fatigue testing machine, this paper conducted a constant amplitude fatigue test on 18 M20 and 14 M30 high strength bolts with 40Cr material, and obtained 19 valid failure points, 9 unspoiled points with more than 2 million cycles, and 4 abnormal failure points. In addition, it established the constant amplitude fatigue design method, ${[{\Delta}{\sigma}]_{{2{\times}10}}{^6=58.91MPa}$, and analyzed the stress concentration and the fatigue fracture of high strength bolts. It can be explained that the geometrical stress concentration of high-strength bolt caused by spiral burr is severe.

Detection of Real Defects in Composite Structures by Laser Measuring System (레이저 계측시스템에 의한 복합재료 구조물의 실제결함 검출)

  • 정성균;김태형;김경석;강영준
    • Composites Research
    • /
    • v.15 no.5
    • /
    • pp.19-26
    • /
    • 2002
  • Real defects in composite structures were detected by using laser measuring system. Four types of real defects, that is, impact-induced delamination in a composite laminate, debond in a honeycomb structure, free-edge delamination in a composite laminate and debond in an adhesive joint, were made by applying several types of loads to the specimens. Laser measuring system such as ESPI and shearography technique were used to detect those defects. Thermal loading method, which can easily induce the surface deformation of specimen, was used to detect the defects. Experimental results show that the defects in composite structures could be easily detected by ESPI and shearography technique. Moreover, it shows that ESPI and shearography technique could be usefully applied to the detection of defects in various kinds of composite structures.

Initial Lengthening Behavior of Cadaveric Achilles Tendon Graft After Posterior Cruciate Ligament Reconstruction (후방십자인대 재건술 후 사체 아킬레스 이식건의 초기연신거동)

  • Kim, Cheol-Woong;Bae, Ji-Hoon;Lee, Ho-Sang;Wang, Joon-Ho;Park, Jong-Woong;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1461-1466
    • /
    • 2008
  • In the case of Posterior Cruciate Ligament (PCL), the most frequent mechanism is the dashboard injury, which is directly pressurized to the anterior of the proximal tibia in the state of the knee hyperflexion. The PCL associated ligament damage happens when the posterior injury, the varus, the valgus, the hyperextension and the severe vagus torque are out of the critical value of PCL. After the successful operation cases of Anterior Cruciate Ligament (ACL) reconstruction using the allograft were informed from 1986, a number of results kept over the maximum 10 years were reported. Unfortunately, PCL reconstruction are crowded the surgery techniques such as the graft, the tibia fixing method, the fixation device, the location of the femoral tunnel, the number of the graft bundles and PCL reconstruction to access to the stability of the normal joint is being developed. Therefore, this study is the basic research of these above facts. The current transtibial tunnel surgery using the cadaveric Achilles tendon grafts is chosen for the various PCL reconstruction. The initial extension of the Achilles tendon by the fixing device and its location under the cyclic loading, were observed.

  • PDF

Management of Diabetic Foot Ulcer (당뇨병성 족부 궤양의 치료)

  • Seo, Dong-Kyo;Lee, Ho Seong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • In patients with diabetic foot, ulceration and amputation are the most serious consequences and can lead to morbidity and disability. Peripheral arterial sclerosis, peripheral neuropathy, and foot deformities are major causes of foot problems. Foot deformities, following autonomic and motor neuropathy, lead to development of over-pressured focal lesions causing the diabetic foot to be easily injured within the shoe while walking. Wound healing in these patients can be difficult due to impaired phagocytic activity, malnutrition, and ischemia. Correction of deformity or shoe modification to relieve the pressure of over-pressured points is necessary for ulcer management. Application of selective dressings that allow a moist environment following complete debridement of the necrotic tissue is mandatory. In the case of a large soft tissue defect, performance of a wound coverage procedure by either a distant flap operation or a skin graft is necessary. Patients with a Charcot joint should be stabilized and consolidated into a plantigrade foot. The bony prominence of a Charcot foot can be corrected by a bumpectomy in order to prevent ulceration. The most effective management of the diabetic foot is ulcer prevention: controlling blood sugar levels and neuropathic pain, smoking cessation, stretching exercises, frequent examination of the foot, and appropriate education regarding footwear.

Development of a Probability Model for Burst Risks of Water Main using the Analysis Methods of Leakage Type (매설환경에 따른 배수관망의 누수발생원인 특성분석)

  • Park, Sang-Bong;Choi, Tae-Ho;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.141-152
    • /
    • 2011
  • In this study, we extracted effective factors of pipe burst from the status data of water asset, operating data of pressure, volume and etc. and 7 years' pipe burst and repair records. The extracted factors were sorted by each attribution and then a statistical analysis was performed to generate a pipe burst probability function using the logistic regression model. As the result, material, diameter, length, laying year, pressure and road width affected to pipe burst significantly. Especially, in case of small diameter, laying year was most effective factor and in case of steel pipe, external loading was main cause of burst, and in case of cast iron, PE, PC, HP pipes, the deterioration of joint was main cause. The other side, as a result of Hosmer-Lemeshow goodness of fit test the models are turned out significant statistically. Also the classification criteria were determined to minimize the total cost from classification errors, when the predicted probability was more than 18% this pipe could have a chance of burst.