• 제목/요약/키워드: Joint/connection

검색결과 564건 처리시간 0.02초

JES 공법의 JOINT ELEMENT 이음부에 관한 연구 (A Study on the Joint Element Connection of Joint Element Structure Method)

  • 엄기영;박명준
    • 한국철도학회논문집
    • /
    • 제5권3호
    • /
    • pp.133-141
    • /
    • 2002
  • Recently developed JES(Joint Element Structure) Method was researched as a more safe and economic method than other under pass construction method and was applied to many construction sites. The joint element connection of JES Method is the most important factor for the to behavior of structure. The connection of JES method is filled with the mortar, and the steel and mortar of connections produce the same behavior as one material. The results of experience and numerical analysis are following: The maximum internal stress of connection is decided by the end of connection. also, The connection of joint element structure method have sufficient internal stress against fatigue.

Studies on seismic performance of the new section steel beam-wall connection joint

  • Weicheng Su;Jian Liu;Changjiang Liu;Chiyu Luo;Weihua Ye;Yaojun Deng
    • Structural Engineering and Mechanics
    • /
    • 제88권5호
    • /
    • pp.501-519
    • /
    • 2023
  • This paper introduces a new hybrid structural connection joint that combines shear walls with section steel beams, fundamentally resolving the construction complexity issue of requiring pre-embedded connectors in the connection between shear walls and steel beams. Initially, a quasi-static loading scheme with load-deformation dual control was employed to conduct low-cycle repeated loading experiments on five new connection joints. Data was acquired using displacement and strain gauges to compare the energy dissipation coefficients of each specimen. The destruction process of the new connection joints was meticulously observed and recorded, delineating it into three stages. Hysteresis curves and skeleton curves of the joint specimens were plotted based on experimental results, summarizing the energy dissipation performance of the joints. It's noteworthy that the addition of shear walls led to an approximate 17% increase in the energy dissipation coefficient. The energy dissipation coefficients of dog-bone-shaped connection joints with shear walls and cover plates reached 2.043 and 2.059, respectively, exhibiting the most comprehensive hysteresis curves. Additionally, the impact of laminated steel plates covering composite concrete floors on the stiffness of semi-rigid joint ends under excessive stretching should not be disregarded. A comparison with finite element analysis results yielded an error of merely 2.2%, offering substantial evidence for the wide-ranging application prospects of this innovative joint in seismic performance.

Modeling of cyclic joint shear deformation contributions in RC beam-column connections to overall frame behavior

  • Shin, Myoungsu;LaFave, James M.
    • Structural Engineering and Mechanics
    • /
    • 제18권5호
    • /
    • pp.645-669
    • /
    • 2004
  • In seismic analysis of moment-resisting frames, beam-column connections are often modeled with rigid joint zones. However, it has been demonstrated that, in ductile reinforced concrete (RC) moment-resisting frames designed based on current codes (to say nothing of older non-ductile frames), the joint zones are in fact not rigid, but rather undergo significant shear deformations that contribute greatly to global drift. Therefore, the "rigid joint" assumption may result in misinterpretation of the global performance characteristics of frames and could consequently lead to miscalculation of strength and ductility demands on constituent frame members. The primary objective of this paper is to propose a rational method for estimating the hysteretic joint shear behavior of RC connections and for incorporating this behavior into frame analysis. The authors tested four RC edge beam-column-slab connection subassemblies subjected to earthquake-type lateral loading; hysteretic joint shear behavior is investigated based on these tests and other laboratory tests reported in the literature. An analytical scheme employing the modified compression field theory (MCFT) is developed to approximate joint shear stress vs. joint shear strain response. A connection model capable of explicitly considering hysteretic joint shear behavior is then formulated for nonlinear structural analysis. In the model, a joint is represented by rigid elements located along the joint edges and nonlinear rotational springs embedded in one of the four hinges linking adjacent rigid elements. The connection model is able to well represent the experimental hysteretic joint shear behavior and overall load-displacement response of connection subassemblies.

Experimental research on load-bearing capacity of cast steel joints for beam-to-column

  • Han, Qinghua;Liu, Mingjie;Lu, Yan
    • Structural Engineering and Mechanics
    • /
    • 제56권1호
    • /
    • pp.67-83
    • /
    • 2015
  • The load transfer mechanism and load-bearing capacity of cast steel joints for H-shaped beam to square tube column connection are studied based on the deformation compatibility theory. Then the monotonic tensile experiments are conducted for 12 specimens about the cast steel joints for H-shaped beam to square tube column connection. The findings are that the tensile bearing capacity of the cast steel joints for beam-column connection depends on the ring of cast steel stiffener. The tensile fracture happens at the ring of the cast steel stiffener when the joint fails. The thickness of square tube column has little influence on the bearing capacity of the joint. The square tube column buckles while the joint without concrete filled, but the strength failure happens for the joint with concrete filled column. And the length of welding connection between square tube column and cast steel stiffener has little influence on the load-bearing capacity of the cast steel joint. Finally it is shown that the load-bearing capacity of the joints for H-shaped beam to concrete filled square tube column connection is larger than that of the joints for H-shaped beam to square tube column connection by 10% to 15%.

강재기둥-PHC 파일 간 반구형 접합부(HAT Joint)의 볼트 연결에 대한 구조성능평가 (Structural Performance Evaluation of Bolt Connection for Half-sphere Joint between PHC Pile and Steel Column)

  • 오진탁;김상봉;김영식;주영규
    • 한국공간구조학회논문집
    • /
    • 제15권4호
    • /
    • pp.65-72
    • /
    • 2015
  • To overcome the weakness of spread foundation in large space structure, the research of precast pile for replace spread foundation have been conducted. The new type of joint between PHC pile and steel column is named HAT Joint(Hollow hAlf-sphere cast-sTeel Joint). It connected PHC Pile by bolt that verification of bolt connection should be accomplished. In this paper, pull-out test and flexural performance for HAT Joint to verifying the bolt connection is explained. As a result, the pull-out and flexural capacities of bolt were checked to use in real structure. Furthermore, the equation of pull-out strength was proposed.

PHC파일간 연결 시공성 개선 이음판형 기계적 연결부의 연결저항 (Connection Resistance of Mechanical Joint using Connection plate for Improvement of Connectivity between PHC piles)

  • 안진희;문홍득;하민균;조광일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.25-32
    • /
    • 2019
  • PHC 파일의 파일간 연결공법으로 용접이음과 볼트이음을 이용한 기계적 이음들이 적용되고 있으나 시공과정 등에서 품질 및 성능 확보에 어려움이 발생할 수 있다. 본 연구는 기존 PHC파일 연결부가 가지는 단점을 개선하고 PHC 파일 연결부 성능을 확보할 수 있는 무용접 이음판형 기계적 PHC파일 연결부를 제안하고 비선형 구조해석과 실제 PHC파일 연결부 실험을 통하여 제안된 PHC 파일 연결부의 연결성능을 평가하였다. 제안된 PHC파일 연결부의 비선형 구조해석 결과 연결부는 휨, 압축, 인장, 전단, 편심압축 하중 상태에서 충분한 연결성능을 확보하는 것으로 평가되었으며, 실제 휨하중 재하실험에서 PHC파일의 균열 및 휨 모멘트 수준 이상에서도 안정적인 선형거동을 가지고 있는 것으로 나타났다. 따라서 제안한 무용접 이음판형 기계적 PHC파일 연결부는 충분한 연결성능을 확보할 수 있는 것으로 판단된다.

Experimental study on through-beam connection system for concrete filled steel tube column-RC beam

  • Tian, Chunyu;Xiao, Congzhen;Chen, Tao;Fu, Xueyi
    • Steel and Composite Structures
    • /
    • 제16권2호
    • /
    • pp.187-201
    • /
    • 2014
  • A new through-beam connection system for a concrete filled steel tube column to RC beam is proposed. In this connection, there are openings on the steel tube while the reinforced concrete beams are continuous in the joint zone. The moment and shear force at the beam ends can be transferred to column by continuous rebar and concrete. The weakening of the axial load and shear bearing capacity due to the opening of the steel tube can be compensated by strengthening steel tube at joint zone. Using this connection, construction of the joint can be made more convenient since welding and hole drilling in situ can be avoided. Axial compression and reversed cyclic loading tests on specimens were carried out to evaluate performance of the new beam-column connection. Load-deflection performance, typical failure modes, stress and strain distributions, and the energy dissipation capacity were obtained. The experimental results showed that the new connection have good bearing capacity, superior ductility and energy dissipation capacity by effectively strengthen the steel tube at joint zone. According to the test and analysis results, some suggestions were proposed to design method of this new connection.

볼트로 겹침이음된 펄트루젼 복합재 접합부의 구조적 거동 (Structural Behavior of Bolted Lap-Joint Connection in the Pultruded FRP Structural Members)

  • 이영근;신광열;주형중;남정훈;윤순종
    • Composites Research
    • /
    • 제23권1호
    • /
    • pp.37-43
    • /
    • 2010
  • 이 연구에서는 볼트로 겹침이음된 펄트루젼 복합재의 접합부에 대한 구조적 거동을 실험적 연구를 통해 조사하였다. 펄트루젼 복합재 접합부의 구조적 거동 조사에 앞서 재료의 역학적 성질을 파악하기 위해 펄트루젼 복합재의 인장 및 전단실험을 수행하였고, 이를 바탕으로 볼트의 수와 배열을 변수로 3종류의 겹침이음 시편을 제작하였다. 겹침이음 접합부 실험은 접합부를 중심으로 인장하중이 작용하도록 하중을 재하하였고, 하중증가에 따른 접합부의 구조적 거동 및 파괴모드를 조사하였다. 실험결과 접합부에 대한 파괴는 대부분 전단파괴로 나타났으며, 실험을 통해 얻어진 데이터를 분석하여 설계를 위한 기초자료로 활용될 수 있도록 하였다.

흙막이 지보공을 연결하기 위한 심플 조인트 공법 (Simple Joint Method for the Connection of the Excavation Support System)

  • 오성남;홍성영;부상혁;류기정
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.336-343
    • /
    • 2005
  • In the braced excavations, careful consideration must be given to the risks of progressive collapse of the entire support system due to failure of a single member. The existing connection methods of the excavation support system results in many problems during construction. To overcome these, simple joint method is proposed in this study. The full scale test and the numerical analysis using finite element method were performed to verify the safety of them. As results, simple joint method was good effective to increase strength. And it was good effective to decrease in numbers of bolt. Also, new method is cheaper than existing connection methods and a good construction as well.

  • PDF

임플랜트와 지대주 간 내측연결 시스템에서 Friction Fit와 Slip Fit에 따른 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis According to Friction Fit or Slip Fit of Internal Connection System between Implant and Abutment)

  • 장두익;정승미;정재헌
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.113-132
    • /
    • 2005
  • The purpose of this study was to assess the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to a friction-fit joint (Astra; Model 1) or slip- fit joint (Frialit-2; Model 2) in the internal connection system under vertical and inclined loading using finite element analysis. In conclusion, in the internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to the abutment connection form had difference among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the abutment post. The magnitude of the stress distributed in the supporting bone, the implant fixture, the abutment and the abutment screw was higher in the friction-fit joint than in the slip-fit joint. But it is considered that the further study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.