• Title/Summary/Keyword: Jeong Cheol

Search Result 8,183, Processing Time 0.044 seconds

Effects of Limestone Powder and Silica Fume on the Hydration and Pozzolanic Reaction of High-Strength High-Volume GGBFS Blended Cement Mortars (고강도 고함량 고로슬래그 혼합 시멘트 모르터의 수화 및 포졸란 반응에 미치는 석회석 미분말과 실리카퓸의 영향)

  • Jeong, Ji-Yong;Jang, Seung-Yup;Choi, Young-Cheol;Jung, Sang-Hwa;Kim, Sung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • To evaluate the effects of limestone powder and silica fume on the properties of high-strength high-volume ground granulated blast-furnace slag (GGBFS) blended cement concrete, this study investigated the rheology, strength development, hydration and pozzolanic reaction characteristics, porosity and pore size distribution of high-strength mortars with the water-to-binder ratio of 20, 50 to 80% GGBFS, up to 20% limestone powder, and up to 10% silica fume. According to test results, compared with the Portland cement mixture, the high-volume GGBFS mixture had much higher flow due to the low surface friction of GGBFS particles and higher strength in the early age due to the accelerated cement hydration by increase of free water; however, because of too low water-to-binder ratio and cement content, and lack of calcium hydroxide content, the pozzolanic reactio cannot be activated and the long-term strength development was limited. Limestone powder did not affect the flowability, and also accelerate the early cement hydration. However, because its effect on the acceleration of cement hydration is not greater than that of GGBFS, and it does not have hydraulic reactivity unlikely to GGBFS, compressive strength was reduced proportional to the replacement ratio of limestone powder. Also, silica fume and very fine GGBFS lowered flow and strength by absorbing more free water required for cement hydration. Capillary porosities of GGBFS blended mortars were smaller than that of OPC mortar, but the effect of limestone powder on porosity was not noticeable, and silica fume increased porosity due to low degree of hydration. Nevertheless, it is confirmed that the addition of GGBFS and silica fume increases fine pores.

The Measurement of Normal Talus in Korean Cadaver (한국인 사체에서의 정상 거골의 실측)

  • Ha, Dong-Jun;Gwak, Heui-Chul;Kim, Jeon-Gyo;Kim, Jung-Han;Lee, Chang-Rak;Kim, Young-Jun;Lee, Jeong-Han;Ha, Byung-Ho;Kim, Ui-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.4
    • /
    • pp.163-169
    • /
    • 2016
  • Purpose: To investigate the measured values of the talus in Koreans. Materials and Methods: We measured 88 tali from 44 cadavers that have been donated between December 2012 and December 2015. Of the cadavers, 27 were male and 17 were female. Their mean age was 73 years. The length and width of the talus were measured using a digital goniometer and vernier caliper. Results: The values of cadaveric measurement, mean maximal width and length, width and length of the dome anterior, width and length of the posterior facet, height and length of the trochlear medial facet, and height and length of the trochlear lateral facet were $43.6{\pm}2.6mm$, $56.5{\pm}3.3mm$, $32.5{\pm}2.0mm$, $42.2{\pm}2.7mm$, $22.2{\pm}2.2mm$, $34.7{\pm}2.0mm$, $15.3{\pm}1.3mm$, $33.3{\pm}2.9mm$, $25.3{\pm}3.3mm$, and $30.8{\pm}2.4mm$ for men and $38.9{\pm}1.6mm$, $53.6{\pm}2.4mm$, $27.9{\pm}2.1mm$, $37.4{\pm}3.2mm$, $20.6{\pm}0.8mm$, $31.9{\pm}1.2mm$, $13.6{\pm}2.6mm$, $28.4{\pm}2.5mm$, $24.9{\pm}2.1mm$, and $28.9{\pm}1.4mm$ for women, respectively. The size of the talus showed an accuracy of 86% when anteroposterior diameter was greater than 59 mm. A difference in the size of the right and left talus was not observed. The mean inclination and declination angles were $24.4^{\circ}{\pm}4.2^{\circ}$ and $28.2^{\circ}{\pm}5.4^{\circ}$ for men, and $24.6^{\circ}{\pm}3.6^{\circ}$ and $24.7^{\circ}{\pm}6.7^{\circ}$ for women (p=0.980, p=0.018), respectively, at least $15^{\circ}$, which showed a big difference for every object up to $37^{\circ}$. Conclusion: This paper, to the best of our knowledge, is the first study to measure the talus in Koreans. There were differences by gender and ethnicity in the in measured talus values. The measurements were smaller than European-Americans and greater than Japanese.

Obstructive Ventilatory Impairment as a Risk Factor of Lung Cancer (폐암의 위험인자로서의 폐쇄성 환기장애)

  • Kim, Yeon-Jae;Park, Jae-Yong;Chae, Sang-Cheol;Won, Jun-Hee;Kim, Jeong-Seok;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.746-753
    • /
    • 1998
  • Background : Cigarette smoking is closely related to both lung cancer and chronic obstructive pulmonary disease. The incidence of lung cancer is higher in patients with obstructive ventilatory impairment than in patients without obstructive ventilatory impairment regardless of smoking. So, obstructive ventilatory impairment is suspected as an independent risk factor of lung cancer. Methods: For the evaluation of the role of obstructive ventilatory impairment as a risk factor of lung cancer, a total of 73 cases comprising 47 cases of malignant and 26 benign solitary pulmonary nodule were analyzed retrospectively. A comparative study of analysis of forced expiratory volume curves and frequencies of obstructive ventilatory impairment were made between cases with malignant and benign nodules. Results: In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups. VC, FVC and $FEV_1$ were not significantly different. whereas $FEV_1/FVC%$ and FEF 25-75% showed a significant decrease in the cases with malignant nodule. The frequency of obstructive ventilatory impairment determined by pulmonary function test was significantly higher in the cases with malignant nodule(23.4%) than in benign nodule(3.8%). When the risk for lung cancer was examined by the presence or absence of obstructive ventilatory impairment using the logistic regression analysis, the unadjusted relative risk for the lung cancer of obstructive ventilatory impairment was 17.17. When the effect of smoking and age were considered, the relative risk was to 8.13. Conclusion: These findings suggest that an obstructive ventilatory impairment is a risk factor of lung cancer.

  • PDF

High VPP Combination Chemotherapy for Advanced Non-Small Cell Lung Cancer (진행된 비소세포 폐암에 대한 High-VPP 복합화학요법의 효과)

  • Hong, Seok-Cheol;Han, Pyo-Seong;Lee, Jong-Jin;Cho, Hai-Jeong;Kim, Ju-Ock;Kim, Sun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.367-377
    • /
    • 1993
  • Background: The benefits of combination chemotherapy in unresectable non-small cell lung cancer remain uncertain. But, according to the recent reports, the response rates of cisplatin-based polychemotherapy regimens are higher than those of single agent. Also, the response rates of high-dose cisplatin group are higher than those of low-dose cisplatin group. In attemp to answer the question whether treatments, combination chemotherapy (high VPP) and combination chemotherapy with radiation therapy, improve survival in advanced non-small cell lung cancer, we begin to study. Method: Thirty-five patients above stage III, diagnosed histologically as non-small cell lung cancer, were enrolled. Among them, nineteen received a combination chemotherapy consisting of VP-16 & high-dose cisplatin (100 $mg/m^2$) and/or radiation therapy. The other group (16 subjects) received no therapy. To investigate the differences of survival and response rates between two groups and the side effects related to therapy, we reviewed patients' records. Results: 1) The overall objective response rate was 47%(9/19) with one complete remission. 2) In patients who received polychemotherapy and radiation therapy, the response rate was 60%(6/10) with one complete remission and survival rates of 3 months, 6 months and 12 months were 100%, 70% and 40%. 3) In patients who received polychemotherapy, the response rate was 33% (3/9) with no complete remission and survival rates of 3 months, 6 months and 12 months were 78%, 67% and 33%. 4) Overall, treated patients survived significantly longer (p<0.05) than non-treated patients (median survival 307 days versus 95 days). 5) Analysis of the various prognostic factors disclosed that good performance status, stage III and squamous cell type showed the good response rates. 6) The toxicities were nausea and/or vomiting (100%), alopecia (90%), anemia (79%), leukopenia (69%), thrombocytopenia (2%), increased creatinine (16%) and neurotoxicity (5%). Conclusion: According to above results, there are relatively good results that high VPP combination chemotherapy in advanced non-small cell lung cancer improves survival in the treated group than in the non-treated group. Thus, it is considerd that we select the patients with proper indications and treat them with effective chemotherpy and radiation therapy. But, because improvement related to high VPP ploychemotherapy is not marked in this study, it is necessary that we should investigate follow-up studies in many cases.

  • PDF

The Effects of High Dose Rate Brachytherapy in Recurrent Obstructive Bronchogenic Cancer after External Irradiation Therapy (외부 방사선 치료 조사후 재발한 기관지내 악성종양에서 고선량율 근접조사치료(High Dose Rate Brachytherapy)의 효과)

  • Cho, Jae-Youn;In, Kwang-Ho;Suh, Jung-Kyung;Kang, Sea-Yong;Shim, Jae-Jeong;Kang, Kyung-Ho;Kim, Kwang-Taak;Kim, Cheol-Yong;Yoo, Sa-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.68-76
    • /
    • 1998
  • Background: Patients with centrally recurred bronchogenic carcinoma make a complaint of many symptoms like hemoptysis, cough & dyspnea. At these conditions, the goal of treatment is only to relieve their symptoms. High dose rate brachytherapy(HDR-BT) is the palliative treatment modality of centrally located endobronchial tumor regardless of previous external irradiation(XRT) on the same site in symptomatic patients. Methods: We studied the effects of HDR-BT in 26 patients with symptomatic recurrent lung cancer. Patients(male: 24, mean age: 54yrs)were treated with HDR-BT underwent bronchoscopic placement of $^{192}Ir$ HDR after loading unit(Gammamed$^{(T)}$, Germany) to deliver 500cGY intraluminal irradiation at a depth of 1cm every lwk on 3 occasions. Evaluation at base line and 4wks after HDR brachytherapy included chest X-ray, bronchscopy, symptoms (Standadized Scale for dyspnea,cough,hemoptysis), and Karnofsky performance scale. Results: Endobronchial obstruction was improved in 11/26 patients(37%). Atelectasis in chest X-ray was improved in 5/15 patients(33%). Hemoptysis, dyspnea & cough were improved in 5/10 patients (50%), 5/8 patients (62%) & 10/18 patients (56%) respectively. Karnofsky performance status was changed from 76.4 scores in pretreatment to 77.6 scores after treatment. During HDR-BT, massive hemoptysis (2 patients) and pneumothorax(1 patient) were occurred as complications. Conclusion: We concluded that HDR-BT gave additional benefits for the control of symptoms and general performance and endobronchial obstruction & atelectasis. And HDR-BT will be an additional treatment for the recurrent and endobronchial obstructive lung cancer.

  • PDF

Semi-quantitative Procalcitonin Assay in Critically ill Patients with Respiratory infections (중환자 호흡 감염에서 반정량적 Procalcitonin 분석)

  • Kim, Ji-Youn;Kim, Cheol-Hong;Park, Sunghoon;Lee, Chang-Youl;Hwang, Yong Il;Choi, Jeong-Hee;Shin, Taerim;Park, Yong-Bum;Jang, Seung-Hun;Lee, Jae Young;Park, Sang Myeon;Kim, Dong-Gyu;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.3
    • /
    • pp.205-211
    • /
    • 2009
  • Background: Serum procalcitonin level has been considered prognostic during sepsis and septic shock. We investigated the significance of procalcitonin in critically ill patients with respiratory infections. Methods: The patients who had radiographically diagnosed diffuse lung infiltrations were enrolled on a prospective basis. Bronchoalveolar lavage (BAL) fluid for the purpose of quantitative cultures (${\geq}10^4$ cfu/mL) was obtained from all patients. Serum procalcitonin levels determined by PCT-Q kit were measured on BAL day and classified as follows; <0.5 ng/mL, 0.5~2.0 ng/mL, 2.0~10.0 ng/mL and >10.0 ng/mL. We analyzed the patient's characteristics according to outcome; favorable or unfavorable, defined as death. Results: Patients from the following categories were included: medical 17 (47.2%), surgical 9 (25%), and burned 10 (27.8%). APACHE II scores on admission to intensive care unit were 11.5${\pm}$6.89 and 11 (30.6%) had unfavorable outcomes. A procalcitonin level ${\geq}$0.5 ng/mL was in 17 (47.2%) of all. On univariate analysis, the frequencies of burn injury, mechanical ventilation, multiple organ failure, and a procalcitonin level ${\geq}$0.5 ng/mL were more often increased in patients with unfavorable outcomes than in those with favorable outcomes (p<.05). Also, a higher procalcitonin range and ventilator-associated pneumonia (VAP) were more closely associated with an unfavorable outcome (p<.05). However in multivariate analysis, a strong predictor of unfavorable outcome was burn injury (p<.05). A procalcitonin level ${\geq}$0.5 ng/mL was more sensitive in predicting VAP than unfavorable outcome. Conclusion: A higher procalcitonin level seems to be associated with VAP, but further study is required to know that procalcitonin would be a prognostic marker in critically ill patients with respiratory infections.

Studies on the Shade Tolerance, Light Requirement and Water Relations of Economic Tree Species(II) -Effects of Artificial Shade Treatment on the Water Potential and Stomatal Diffusive Resistance of Four Deciduous Hardwood Species- (주요경제수종(主要經濟樹種)의 내음성(耐陰性) 및 광선요구도(光線要求度)와 수분특성(水分特性)에 관한 연구(硏究)(II) -인공피음(人工被陰)이 활엽수(闊葉樹) 4종(種)의 수분(水分)포텐셜 및 기공증산저항(氣孔蒸散低抗)에 미치는 영향(影響)-)

  • Kwon, Ki Won;Choi, Jeong Ho;Chung, Jin Cheol
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.198-207
    • /
    • 2000
  • The diurnal and seasonal changes of water potential and stomatal diffusive resistance were investigated with the effects of shade treatment to elucidate the water relations of the one year old seedlings of Betula platyphylla var. japonica, Zelkova serrata, Acer mono, and Prunus sargentii subjected to five levels of artificial shade treatments from full sun to nearly full shading of 2-6% relative light transmittance. Stomatal diffusive resistance measured in the four deciduous hardwood species studied changed variously by growing season and by species with the five shade treatments in the ranges of 1.7~25.1s/cm in 9 a.m., 2.3~33.3s/cm in 1 p.m., and 1.1~36.8s/cm in 5 p.m.. The measurements of stomatal diffusive resistance increased with increasing the shading, and were higher in September than in June or July in most of the species studied. The stomatal diffusive resistance measured in Zelkova serrata, Acer mono, and Prunus sargentii seemed to be approximately 3~4 times higher in nearly full shading treatment than in full sun. Water potential also changed variously by growing season and by species with five different shade treatments in the ranges of -0.17~-1.20MPa in 9 a. m., -0.30~-2.03MPa in 1 p. m., and -0.18~-1.34MPa in 5 p.m., respectively. On the reverse of stomatal diffusive resistance, the measurements of water potential were lower in September than in June or July in most of the species studied, and the seasonal differences were especially greater in Zelkova serrata comparing with the other species. The water potential seemed to be higher of approximately 2~3 times in nearly full shading treatment than in full sun in all of the species studied, but the differences among the shading treatments were less in water potential than in stomatal diffusive resistance. The differences of water potential following the gradient of five shading treatment seemed to be less in Betula platyphylla var. japonica than in the other species. In Acer mono and Prunus sargentii being some shade tolerant species, the water potential increased rapidly through about noontime with raising the shading level from full sun to the intermediate shading level of 22-28% relative light transmittance, but slowly with closing to full shading. In Betula platyphylla var. japonica and Zelkova serrata being shade intolerant species, the water potential increased gradually throughout the shading levels and the increment ranges were greater in Zelkova serrata than in Betula platyphylla var. japonica.

  • PDF

Development of Prediction Equation of Diffusing Capacity of Lung for Koreans

  • Hwang, Yong Il;Park, Yong Bum;Yoon, Hyoung Kyu;Lim, Seong Yong;Kim, Tae-Hyung;Park, Joo Hun;Lee, Won-Yeon;Park, Seong Ju;Lee, Sei Won;Kim, Woo Jin;Kim, Ki Uk;Shin, Kyeong Cheol;Kim, Do Jin;Kim, Hui Jung;Kim, Tae-Eun;Yoo, Kwang Ha;Shim, Jae Jeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.1
    • /
    • pp.42-48
    • /
    • 2018
  • Background: The diffusing capacity of the lung is influenced by multiple factors such as age, sex, height, weight, ethnicity and smoking status. Although a prediction equation for the diffusing capacity of Korea was proposed in the mid-1980s, this equation is not used currently. The aim of this study was to develop a new prediction equation for the diffusing capacity for Koreans. Methods: Using the data of the Korean National Health and Nutrition Examination Survey, a total of 140 nonsmokers with normal chest X-rays were enrolled in this study. Results: Using linear regression analysis, a new predicting equation for diffusing capacity was developed. For men, the following new equations were developed: carbon monoxide diffusing capacity (DLco)=-10.4433-0.1434${\times}$age (year)+0.2482${\times}$heights (cm); DLco/alveolar volume (VA)=6.01507-0.02374${\times}$age (year)-0.00233${\times}$heights (cm). For women the prediction equations were described as followed: DLco=-12.8895-0.0532${\times}$age (year)+0.2145${\times}$heights (cm) and DLco/VA=7.69516-0.02219${\times}$age (year)-0.01377${\times}$heights (cm). All equations were internally validated by k-fold cross validation method. Conclusion: In this study, we developed new prediction equations for the diffusing capacity of the lungs of Koreans. A further study is needed to validate the new predicting equation for diffusing capacity.

Analysis of Temperature Changes in Greenhouses with Recirculated Water Curtain System (순환식 수막하우스의 수온에 따른 플라스틱 온실 내 온도변화 분석)

  • Kim, Hyung-Kweon;Jeon, Jong-Gil;Paek, Yee;Pyo, Hee-Young;Jeong, Jae-Woan;Kim, Yong-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.93-99
    • /
    • 2015
  • The purpose of this study was to determine the appropriate temperature for water curtain in greenhouses equipped with recirculated water curtain system. The study analyzed the changes in air temperature in non-heated greenhouses for strawberry cultivation based on outdoor temperature, water curtain temperature and night time. Three greenhouse units were used for this study: The first unit was assigned as a control (no water curtain system), two other greenhouses were equipped with recirculated water curtain system with water curtain temperatures of $10^{\circ}C$ and $15^{\circ}C$, respectively. Analysis showed that the indoor temperatures were directly correlated with the outdoor temperature in all experimental greenhouses. Heat insulating effect of $15^{\circ}C$ water curtain was increased by $1.3^{\circ}C$ compared to that in $10^{\circ}C$ water curtain system. The $15^{\circ}C$ water curtain treatment showed the highest average temperature and less temperature variation in comparison with control and $10^{\circ}C$ water curtain treatment. To maintain indoor temperature at $5^{\circ}C$, water curtain temperature of $10^{\circ}C$ was suitable when outdoor minimum and average temperatures were -1.3 and $1.5^{\circ}C$, and water curtain temperature of $15^{\circ}C$ was suitable when outdoor minimum and average temperatures were -4.7 and $-0.2^{\circ}C$, respectively. The highest temperature in greenhouses according to measurements in different periods of night time was observed after sunset (18:30-20:30), and the lowest temperature before sunrise (05:00-07:00). Water curtain maintained a target indoor temperature by acting as a layer of heat transfer insulator which decreased heat loss from greenhouses. Therefore, water temperature in recirculating water curtain systems should be determined by considering outdoor temperatures, changes in temperature at different periods of night time, and cultivated crop.

Effect of High Temperature and High Humidity on Protein Expression and Plasma Membrane $H^{+}ATPase$ of Umbel with Flower of Onion (Allium cepa L.) (고온과 고습 조건하에서 양파 화구의 총 단백질의 발현과 원형질막 $H^{+}ATPase$의 영향)

  • Ku, Yang-Gyu;Park, Won;Lee, Eul-Tai;Kim, Cheol-Woo;Oh, Jeong-Min;Jang, Young-Seok;Kim, Yong-Kwon;Ahn, Sung-Ju
    • Journal of Bio-Environment Control
    • /
    • v.18 no.2
    • /
    • pp.160-165
    • /
    • 2009
  • This study was undertaken the effect of high temperature and high humidity on protein expression and especially plasma membrane (PM) $H^{+}ATPase$ of umbel with flowers of early cultivar 'Shinsunhwang' and intermediate cultivar 'Maebsihwang' of onion (Allium cepa L.). There were no visible any difference on the protein pattern from before flowering stage to full flowering stage of two onion cultivars, however, seed set stages were revealed induced/deduced protein patterns. At day 18, protein expression pattern of the high temperature and high humidity treatments of two cultivars was significantly reduced compared to controls. Furthermore, various protein expression of the high temperature treatment was more reduced compared to high humidity treatment. PM $H^{+}ATPase$ expression of the control plants of two onion cultivars was clearly shown, but was not detectable under high temperature treatment of the two onion cultivars using western blot analysis. PM $H^{+}ATPase$ expression of the high humidity treatment was faintly detected intermediate cultivar 'Maebsihwang', not early cultivar 'Shinsunhwang'. These results indicate that protein expression pattern and PM $H^{+}ATPase$ under high temperature treatment was considered to be more damaged compared to high humidity.