• Title/Summary/Keyword: Jaw size

Search Result 91, Processing Time 0.029 seconds

A study on the relationship between jaw size and tooth size (치아크키와 악골크기의 상관관계에 관한 연구)

  • Ahn, Hyo-Beom;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.33 no.3 s.98
    • /
    • pp.157-167
    • /
    • 2003
  • The purpose of this study was to find whether there is a correlation between tooth size and jaw size. Dental stone models and cephalometric radiographic films of 87 untreated individuals were evaluated. Repeated measurements of the maximum mesiodistal width of the teeth were taken by means of a digital vernier caliper. Linear measurements of jaw size were assessed by means of a digitizer and Visual C++ program. All measurements were taken separately according to the subject's gender. To determine the relationship between jaw and tooth size, the Pearson correlation was used. The results were as follows: 1. Male and female subjects showed a statistical difference in regard to tooth size and jaw size 2. In contrast to the results of the male subjects, there were no statistically significant correlations between maxillary size and maxillary teeth size in female subjects 3. In male subjects, the two maxillary sizes of PTM vert-ANS vert (FH plane) and PTM vert-A yen (palatal plane) were significantly correlated with themaxillary teeth size. Especially, the size of the upper central incisor showed significant correlation with all maxillary sizes. 4. In both male and female subjects, mandibular size B vert- Point J vert (mandibular plane) showed significant correlation with mandibular teeth size. As gleaned kom the results of this study, the relationship between jaw size and tooth size was fair or little in natural occurring good occlusion.

The study on dose variation due to exchange of Upper and Lower jaw in the linear accelerator (선형가속기에서 상위조리개와 하위조리개의 교환에 의한 선량 변화의 고찰)

  • Lim CK.;Kim HN.;Song KW.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 1999
  • The field size can be beam output, therefore MonitorUnit can be varied due to field size dependence The purpose of this study is to evaluate and compare the dose variation according to exchange of collimator The measurements were perfomed with Wellhofer dosimetry system(water phantom. ion chamber. electrometer. system controller. build up cap. etc)and two types of linear accerlerator (Mevatron KD, MevatronMX) Scatter can be affected to field size dependence and scatter correction is separated into collimator and phantom components, scatter components can affect by exchanging of collimator Measurements of collimator scatter factor(Sc) was done in air with build up cap. 1)Square field (5cm2 to 40cm2) was measured 2)and then keeping the upper jaw constant at loom and varing lower jaw from 5cm to 40cm, 3)keeping the lower jaw constant at 10cm and varing upper jaw from 5cm to 40cm Measurements of total scatter factor(Scp) was done in water at Dmax as the procedure of collimator scatter factor measurements in water Dmax The total scatter factors were obtained to the following equation(Sp=Scp/Sc) The measured data is normalized to the data of reference field size($10{\times}10$), rectangular field is inverted to equivalent field to compare three field size data As the collimator setting is varied, the output was changed In conclusion, the error was obtained small but it must be eliminated if we intend to reach the common stated goal of $5\%$ overall uncertainty in dose determination

  • PDF

Fetal dose from Head and Neck Tomotherapy Versus 3D Conformal Radiotherapy

  • Park, So Hyun;Choi, Won Hoon;Choi, Jinhyun
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.4
    • /
    • pp.156-160
    • /
    • 2019
  • Background: To compare the dose of radiation received by the fetus in a pregnant patient irradiated for head and neck cancer using helical tomotherapy and three-dimensional conformal radiation therapy (3DCRT). Materials and Methods: The patient was modeled with a humanoid phantom to mimic a gestation of 26 weeks. Radiotherapy with a total dose of 2 Gy was delivered with both tomotherapy (2.5 and 5.0 cm jaw size) and 3DCRT. The position of the fetus was predicted to be 45 cm from the field edge at the time of treatment. The delivered dose was measured according to the distance from the field edge and the fetus. Results and Discussion: The accumulated dose to the fetus was 1.6 cGy by 3DCRT and 2 and 2.3 cGy by the 2.5 and 5 cm jaw tomotherapy plans. For tomotherapy, the fetal dose with the 2.5 cm jaw was lower than that with the 5 cm jaw, although the radiation leakage was greater for 2.5 cm jaw plan due to the 1.5 fold longer beam-on time. At the uterine fundus, tomotherapy with a 5 cm jaw delivered the highest dose of 2.4 cGy. When the fetus moves up to 35 cm at the 29th week of gestation, the resultant fetal doses for 3DCRT and tomotherapy with 2.5 and 5 cm jaws were estimated as 2.1, 2.7, and 3.9 cGy, respectively. Conclusion: For tomotherapy, scattering radiation was more important due to the high monitor unit values. Therefore, selecting a smaller jaw size for tomotherapy may reduce the fetal dose. however, evaluation of risk should be individually performed for each patient.

A Study on the Impact Load Quantification of the Jaw Crusher (쇄석기의 충격하중 정량화에 대한 연구)

  • Hong, Sung Ju;Yang, Hae Jeong
    • Journal of Drive and Control
    • /
    • v.16 no.2
    • /
    • pp.1-7
    • /
    • 2019
  • Jaw crusher is a device that breaks rock collected from mines or quarries to produce aggregates of the size desired by user. A representative method for measuring load is to measure them by attaching force sensors directly to the part where the load is generated. However, the direct method has many limitations such as high-impact loads generation in equipment or space constraints, sensor capacities and costs. Therefore, Transfer Path Analysis (TPA) was used to indirectly measure impact loads by attaching acceleration sensors. In this study, both direct and TPA methods were used to measure the impact load of Jaw crusher. This study finally quantifies the impact of the load generated by the Jaw crusher using direct method and TPA method, and comparing the impact load measured calculated the derive the error rate.

Prognostic factors for outcome of surgical treatment in medication-related osteonecrosis of the jaw

  • Shin, Woo Jin;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.4
    • /
    • pp.174-181
    • /
    • 2018
  • Objectives: The number of patients with medication-related osteonecrosis of the jaw (MRONJ) is increasing, but treatment remains controversial. Published papers and systematic reviews have suggested that surgical treatment is effective in patients with MRONJ. The purpose of this study was to determine whether preoperative University of Connecticut Osteonecrosis Numerical Scale (UCONNS), other serologic biomarkers, and size of necrosis are prognostic factors for outcome of surgical treatment in MRONJ. Materials and Methods: From January 2008 to December 2016, 65 patients diagnosed with MRONJ at the Department of Oral and Maxillofacial Surgery in College of Dentistry, Dankook University who required hospitalization and surgical treatment were investigated. Patient information, systemic factors, and UCONNS were investigated. In addition, several serologic values were examined through blood tests one week before surgery. The size of osteolysis was measured by panoramic view and cone-beam computed tomography in all patients. With this information, multivariate logistic regression analysis with backward elimination was used to examine factors affecting postoperative outcome. Results: In multivariate logistic analysis, higher UCONNS, higher C-reactive protein (CRP), larger size of osteolysis, and lower serum alkaline phosphate were associated with higher incidence of incomplete recovery after operation. This shows that UCONNS, CRP, serum alkaline phosphate, and size of osteolysis were statistically significant as factors for predicting postoperative prognosis. Conclusion: This study demonstrated that CRP, UCONNS, serum alkaline phosphate, and size of osteolysis were statistically significant factors in predicting the prognosis of surgical outcome of MRONJ. Among these factors, UCONNS can predict the prognosis of MRONJ surgery as a scale that includes various influencing factors, and UCONNS should be used first as a predictor. More aggressive surgical treatment and more definite surgical margins are needed when the prognosis is poor.

Birth Ecology and Food Proceeding of Larvae in Red Marbled Rockfish, Sebastiscus tertius (붉은 쏨뱅이, Sebastiscus tertius의 출산생태와 먹이계열)

  • 김광수;임상구;김철원;정장환
    • Journal of Aquaculture
    • /
    • v.12 no.4
    • /
    • pp.309-315
    • /
    • 1999
  • In order to understand the initial feeding time of larvae red marbled rockfish, Sebastiscus tertius changes of mouth size were investigated. Also, the fecundity of different size of red marbled rockfish broodstocks was measured. The broodstocks of red marbled rockfish, S. terius of $32.3\pm6.52 cm$ and larger than 45cm in total length spawned 296,648 and 600,000 larvae, respectively. About 50% was normal healthy larvae among the spawned ones. Mouth sizes calculated by the angle mouth opening and upper jaw length for newly spawned red marbled rockfish larvae were 0.263, 0.197 and 0.132 mm at D, 0.75D and 0.5D, respectively, when the upper jaw length was 0.186mm. Thereafter, 20 days old larvae showed 0.822, 0.617 and 0.411 mm in calculated mouth length at D, 0.75D and rockfish larvae grows, their upper jaw length gradually increased. 2 days old red marbled rockfish larvae possibly stated to feed rotifers and lasted their feeding for the another 35days, relatively long periods compared with other larvae fish. And 25 days old larvae possibly fed the newly hatched Artemia nauplii and lasted their feeding for the another 20 days, like other larvae fish. The proper supplying time of artificial feeds for the red marbled rockfish larvae seemed to be around 10 days after spawning.

  • PDF

Slip Considered Design and Analysis Pincers-type Gripper for Seizing Heavy-weighted Cylindrical Objects (고중량의 원통형 작업대상물 파지용 집게형 그리퍼의 슬립 조건과 이를 반영한 설계 및 해석)

  • Choi, Jung Hyun;An, Jinung;Lee, Sang Mun;Jang, Myeong Eon
    • The Journal of Korea Robotics Society
    • /
    • v.10 no.4
    • /
    • pp.193-199
    • /
    • 2015
  • This paper dealt with a pincers-type gripper being able to grip a heavy-weighted cylindrical object having various size with itself. This gripper should be designed to seize the objects without any change of jaw shape. Grasping achieved equilibrium after the object slipped on the jaw while grasping it. To cope with this situation, we suggested the slip considered gripper design procedure based on grasping equilibrium. The obtained slip condition can provide a limit friction coefficient depending on the contact angle when initiating contact between jaw and object. Consequently, the gripping force and the required actuating force can be calculated. In order to verify the proposed slip condition, the simulations were performed using a dynamic software.

Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking (Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가)

  • Kim, Tae Won;Yoo, Soon Mi;Jeon, Soo Dong;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.73-81
    • /
    • 2018
  • Purpose : The aims of this study were to compare and assess the effectiveness of Volumetric Modulated Arc Therapy(VMAT) using jaw tracking(JT) and fixed jaw(FJ) in radiation therapy of multiple brain metastasis. Methode and material : Among the patients with Multiple Brain Metastasis treated with jaw tracking, 10 patients with more than 6 tumors and with the size of radiation field $14{\times}14cm^2$ or more were included. Each Treatment plans with jaw tracking(JT) and fixed jaw(FJ) was established with Eclipse (Ver. 13.6 Varian, USA). Gamma Index (3 mm, 3 % confidence interval - 95 %) and maximum dose difference were measured with an electronic portal imaging device(EPID). The $D_{max}$ and $D_{mean}$ of Organ At Risk(OAR) were assessed and compared, and the Conformity Index(CI) and Homogeneity Index(HI) were evaluated. Result : Evaluating jaw tracking(JT) and fixed jaw(FJ) outcomes, in all cases, Gamma Index met the permissible standard of 3 mm, 3 % confidence intervals of 95 %. The maximum dose difference value from the areas with leaf end transmission was measured at a maximum of 98.4 % and an average of 43.6 % in clockwise(CW), and 67.9 % and 41.0 % for each in Counter-Clockwise(CCW). With jaw tracking, the maximum value of $D_{max}$ for each normal organ in OAR decreased in 15.36 %~74.59 % with the average value decreasing in 2.84 %~39.80 %. The maximum value of $D_{mean}$ in OAR decreased in 27.90 %~65.23 %, with the average value decreasing in 7.70 %~41.71 %. No change has been found in Conformity Index and Homogeneity Index values. Conclusion : When Jaw tracking is used in treating patients with multiple brain metastasis with VMAT, the unnecessary exposure due to leakage and transmission of radiation in unspecified areas was reduced, without affecting the dose distribution of the planning target volume(PTV), and the availability of radiation therapy with lower doses in normal organs is expected.

  • PDF

Semi-longitudinal study of adenoid and jaw growth of normal occlusal children aged 6 to 17 (6세에서 17세 사이의 정상 교합 아동의 아데노이드와 악골의 성장에 관한 준종단적 연구)

  • Yu, Hyung-Soeg;Park, Sun-Hyung;Choi, Eun-Bin;Mun, Je-Sang;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.699-712
    • /
    • 2000
  • Reduced nasal breathing can influence the growth at)d development of facial structures. It nay have many causes, and enlarged adenoid is the most frequent one. To investigate the effects of adenoids to jaw growth, we must first understand the normal growth of adenoids and jaws, and the relationship between size of adenoids and the values lot the jaw variables. The purpose of this study is to present a more objective standard of nasopharyngeal size and jaw dimension at each bone age, by using Cervical Vertebrae Maturation Index(CYMI) of Hassel, from normal occlusion children aged 6 to 17. The results of this study suggests as follows : 1. At same bone age, female's chronologic age was about 2 year older than male. 2. There was a growth peak of nasopharyngeal(NP) height and depth between CVMI 1 to 2 in male, hut in female NP height and depth gradually increase through CVMI 1 to 6. 3. Relative airway of nasopharynx increases the most between CVMI 1 to 2 period in both gender 4. Among adenoid measurements, Ad2-related variables and upper pharynx, and among dentofacial measurements inter canine width in both arch, maxillary intermolar width and palatal depth had high correlation coefficient with adenoid percentage.

  • PDF

Design and fabrication of microgripper using thermal actuator and SU-8 (열 구동 엑츄에이터와 SU-8을 이용한 마이크로 그리퍼 설계 및 제조)

  • Jung, Seoung-Ho;Park, Joon-Shik;Lee, Min-Ho;Park, Sang-Il;Lee, In-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1613-1616
    • /
    • 2007
  • A microgripper using thermal actuator and SU-8 polymer was designed and fabricated to manipulate cells and microparts. A chip size of a microgripper was 3 mm ${\times}$ 5 mm. The thermally actuated microgripper consisted of two couples of hot and cold arm actuators. The high thermal expansion coefficient, 52 $ppm/^{\circ}C$, of SU-8 compared to silicon and metals, allows the actuation of the microgripper. Thickness and width of SU-8 as an end-effector were 26 ${\mu}m$ and 80 ${\mu}m$, respectively. Initial gap between left jaw and right jaw was 120 ${\mu}m$. The ANSYS program as FEM tool was introduced to analyze the thermal distribution and displacement induced by thermal actuators. $XeF_2$ gas was used for isotropic silicon dry etching process to release SU-8 end-effector. Mechanical displacements of the fabricated microgripper were measured by optical microscopy in the range of input voltage from 0 V to 2.5 V. The maximum displacement between two jaws of a microgripper Type OG 1_1 was 22.4 ${\mu}m$ at 2.5 V.

  • PDF