• Title/Summary/Keyword: Jaw fixation technique

Search Result 11, Processing Time 0.021 seconds

Comparison of hybrid arch bar versus conventional arch bar for temporary maxillomandibular fixation during treatment of jaw fractures: a prospective comparative study

  • Samriddhi Burman;Santhosh Rao;Ankush Ankush;Nakul Uppal
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.6
    • /
    • pp.332-338
    • /
    • 2023
  • Objectives: This study aimed to compare the effectiveness of a hybrid arch bar (hAB) with the conventional Erich arch bar (EAB) for the management of jaw fractures, focusing on their use for temporary fixation in patients undergoing open reduction and internal fixation (ORIF). Materials and Methods: Patients presenting with maxillary and mandibular fractures at our institution were included in this prospective, comparative study. Placement time and ease of occlusal reproducibility were recorded intraoperatively for Group A (hAB patients) and Group B (EAB patients). The primary outcome was comparison of the postoperative stability of the two arch bars. Postoperative measurements also included mucosal overgrowth, screw loosening or wire retightening, and replacement rates. The data were tabulated and computed with a P<0.05 considered statistically significant. Results: The study included 41 patients. A statistically significant difference was observed in postoperative stability scores (3) between Group A and Group B (85.0% vs 9.5%, P=0.001). The mean placement time in Group A (23.3 minutes) significantly differed from that in Group B (86.4 minutes) (P<0.001). The ease of intraoperative occlusion was not different between the two groups (P=0.413). Mucosal overgrowth was observed in 75.0% of patients (15 of 20) in Group A. Conclusion: The hAB was superior to EAB in clinical efficiency, maxillomandibular fixation time reduction, stability, versatility, and safety. Despite temporary mucosal overgrowth, the benefits of hAB outweigh the disadvantages. The choice between hAB and EAB should be based on specific clinical requirements.

Study of the Plating Methods in the Experimental Model of Mandibular Subcondyle Fracture (하악골 과두하부 골절 실험모델에서 견고정을 위한 플레이트 고정방법 연구)

  • Lee, Won;Kang, Dong Hee
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.1
    • /
    • pp.12-16
    • /
    • 2011
  • Purpose: This study examined the biomechanical stability of four different plating techniques in the experimental model of mandibular subcondyle fracture. Methods: Twenty standardized bovine tibia bone samples ($7{\times}1.5{\times}1.0cm$) were used for this study. Each of the four sets of tibia bone was cut to mimic a perpendicular subcondyle fracture in the center area. The osteotomized tibia bone was fixed using one of four different fixation groups (A,B,C,D). The fixation systems included single 2.0 mm 4 hole mini adaption plate (A), single 2.0 mm 4 hole dynamic compression miniplate (B), double fixation with 2.0 mm 4 hole mini adaption plate (C), double fixation with a 2.0 mm 4 hole mini adaption plate and 2.0 mm 4 hole dynamic compression miniplate (D). A bending force was applied to the experimental model using a pressure machine (858 table top system, $MTS^{(R)}$) until failure occurred. The load for permanent deformation, maximum load of failure were measured in the load displacement curve with the chart recorder. Results: Double fixation with a 2.0 mm 4 hole mini adaption plate and a 2.0 mm 4 hole dynamic compression miniplate (D) applied to the anterior and posterior regions of the subcondyle experimental model showed the highest load to failure. Conclusion: From this study, double fixation with an adaption plate and dynamic compression miniplate fixation technique produced the greatest biomechanical stability. This technique may be considered a useful means of fixation to reduce the postoperative internal maxillary fixation period and achieve early mobility of the jaw.

A simple method of intraoperative intubation tube change

  • Cho, Jin Yong;Kim, Hyeon Min;Ryu, Jae Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.5
    • /
    • pp.250-252
    • /
    • 2014
  • Nasotracheal intubation should be performed in patients with jaw fractures because maxillomandibular fixation is required. However, when there are concomitant fractures of the nose and facial bones, an intubation tube positioned at the nose makes it difficult to perform an intricate surgery. In order to overcome these problems, a variety of ways to change the position of the tube have been introduced. We describe a simple technique of switching the tube from a nasal to oral position, which was easily executed in a patient with concomitant nasal and mandibular fractures, accompanied by a literature review.

OPEN REDUCTION AND TRANSORAL FIXATION USING TROCHAR FOR MANDIBULAR SUBCONDYLE FRACTURE (구강 접근과 트로카를 이용한 하악 과두하부 골절의 정복과 고정)

  • Hur, Jun-Young;Kim, Jong-Yun;Lim, Jae-Hyung;Park, Kwang-Ho;Huh, Jong-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • The mandibular condyle fracture occurs at 15-30% frequency of whole mandibular fracture. The treatment of choice is open reduction or closed reduction. In many cases, closed reduction is preferred for treatment of condylar fracture because it is hard to approach to condyle and there is risk of surgical complications, such as nerve damage in open reduction. Open reduction, however, has some advantages like possibility of anatomical reduction, occlusal stability and rapid functional recovery. Furthermore, it is possible to retain original ramal heights and to decrease deviation during mouth opening. There are many surgical approaches for open reduction of subcondyle fracture. At present, transoral approach using trochar device is tried for effective and minimally invasive method for open reduction of subcondyle fracture. And the authors report the cases of reduction of subcondyle fracture with transoral approach using trochar device.

The Effect of a Condylar Repositioning Plate on Condylar Position and Relapse in Two-Jaw Surgery

  • Jung, Gyu Sik;Kim, Taek Kyun;Lee, Jeong Woo;Yang, Jung Dug;Chung, Ho Yun;Cho, Byung Chae;Choi, Kang Young
    • Archives of Plastic Surgery
    • /
    • v.44 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • Background Numerous condylar repositioning methods have been reported. However, most of them are 2-dimensional or are complex procedures that require a longer operation time and a highly trained surgeon. This study aims to introduce a new technique using a condylar repositioning plate and a centric relation splint to achieve a centric relationship. Methods We evaluated 387 patients who had undergone surgery for skeletal jaw deformities. During the operation, a centric relation splint, intermediate splint, final centric occlusion splint, and condylar repositioning plate along with an L-type mini-plate for LeFort I osteotomy or a bicortical screw for bilateral sagittal split ramus osteotomy were utilized for rigid fixation. The evaluation included: a physical examination to detect preoperative and postoperative temporomandibular joint dysfunction, 3-dimensional computed tomography and oblique transcranial temporomandibular joint radiography to measure 3-dimensional condylar head movement, and posteroanterior and lateral cephalometric radiography to measure the preoperative and postoperative movement of the bony segment and relapse rate. Results A 0.3% relapse rate was observed in the coronal plane, and a 2.8% relapse rate in the sagittal plane, which is indistinguishable from the dental relapse rate in orthodontic treatment. The condylar repositioning plate could not fully prevent movement of the condylar head, but the relapse rate was minimal, implying that the movement of the condylar head was within tolerable limits. Conclusions Our condylar repositioning method using a centric relation splint and miniplate in orthognathic surgery was found to be simple and effective for patients suffering from skeletal jaw deformities.

Comparison of intermaxillary fixation techniques for mandibular fractures with focus on patient experience

  • Kim, Young Geun;Yoon, Sung Ho;Oh, Jae Wook;Kim, Dae Hwan;Lee, Keun Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 2022
  • Background: Intermaxillary fixation (IMF) is a technique that allows for the reduction and stabilization of mandibular fractures. Several methods of IMF, such as self-tapping screws or arch bars, have been developed. This study aimed to validate the usefulness of IMF with a self-tapping screw compared to IMF with arch bars with focus on the patients' perspective. Methods: We retrospectively reviewed the medical records of all patients who were treated for mandibular fractures at our hospital between August 2014 and February 2021. A total of 57 patients were enrolled in this study. Thirteen patients were excluded from the analysis: three patients were lost to follow-up, and 10 patients did not undergo IMF. Finally, 44 patients were analyzed, of which 31 belonged to the arch bar group, and 13 belonged to the screw group. Patient discomfort and pain during IMF application and removal were analyzed using a patient self-assessment questionnaire. The surgeon also assessed oral hygiene, IMF stability, and occlusion. Results: We applied IMF to 34 men (77%) and 10 women (23%). The mean age of the patients was 37.3 years. The most common fracture site was the angle (30%), followed by the parasymphysis (25%), the body (23%), the condyle (11%), and the ramus (11%). Patient discomfort and oral hygiene were statistically favorable in the screw group. The IMF application time was statistically shorter in the screw group (p< 0.001). IMF stability was not statistically different between the two groups. The pain score during IMF removal was lower in the screw group (p< 0.001). Conclusion: Compared to arch bars, IMF screws provide more comfort during the IMF period, help maintain favorable oral hygiene, and have a shorter application time. From the patient's perspective, IMF screws are an excellent alternative to conventional arch bars when applicable.

Surgical Management of Edentulous Atrophic Mandible Fractures in the Elderly

  • Chee, Nam Seok;Park, Seong June;Son, Min Ho;Lee, Eoy Jung;Lee, Soo Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.5
    • /
    • pp.207-213
    • /
    • 2014
  • Fractures of the mandible occur with a greater frequency in the elderly. This study reports three cases of edentulous atrophic mandible fracture in elderly patients treated with open reduction technique. Three patients who presented with edentulous atrophic mandible fractures underwent surgical management using open reduction and internal fixation. After treatment, clinical evaluations and postoperative complications were examined with postoperative x-ray. Patients were followed with clinical and radiographic examinations. In the postoperative clinical evaluation, two male patients healed well, but one female patient complained of pain and swelling. In radiographic examinations, no union delay or lack of fusion was observed in the edentulous area. Open reduction technique is a viable treatment option for the edentulous atrophic mandible fractures in geriatric patients.

Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report

  • Agustin-Panadero, Ruben;Penarrocha-Oltra, David;Gomar-Vercher, Sonia;Ferreiroa, Alberto;Penarrocha-Diago, Miguel
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.264-270
    • /
    • 2015
  • This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The technique was used to rehabilitate a patient presenting an atrophic upper maxilla, with the insertion of 8 implants. No complications were reported at follow-up 3, 6 and 12 months after fitting of the prosthesis. This system offers solutions to the clinical and laboratory complications associated with hybrid prostheses, concealing emergence of the chimneys and improving implant-prosthesis hygiene.

Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

  • Santos, Zarina Tatia Barbosa Vieira;Goulart, Douglas Rangel;Sigua-Rodriguez, Eder Alberto;Pozzer, Leandro;Olate, Sergio;Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.77-82
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance ($162.72{\pm}42.55N$), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

Infraorbital nerve transpositioning into orbital floor: a modified technique to minimize nerve injury following zygomaticomaxillary complex fractures

  • Kotrashetti, Sharadindu Mahadevappa;Kale, Tejraj Pundalik;Bhandage, Supriya;Kumar, Anuj
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.2
    • /
    • pp.74-77
    • /
    • 2015
  • Objectives: Transpositioning of the inferior alveolar nerve to prevent injury in lower jaw has been advocated for orthognathic, pre-prosthetic and for implant placement procedures. However, the concept of infra-orbital nerve repositioning in cases of mid-face fractures remains unexplored. The infraorbital nerve may be involved in trauma to the zygomatic complex which often results in sensory disturbance of the area innervated by it. Ten patients with infraorbital nerve entrapment were treated in similar way at our maxillofacial surgery centre. Materials and Methods: In this article we are reporting three cases of zygomatico-maxillary complex fracture in which intra-operative repositioning of infra-orbital nerve into the orbital floor was done. This was done to release the nerve from fractured segments and to reduce the postoperative neural complications, to gain better access to fracture site and ease in plate fixation. This procedure also decompresses the nerve which releases it off the soft tissue entrapment caused due to trauma and the organized clot at the fractured site. Results: There was no evidence of sensory disturbance during their three month follow-up in any of the patient. Conclusion: Infraorbital nerve transposition is very effective in preventing paresthesia in patients which fracture line involving the infraorbital nerve.