• Title/Summary/Keyword: Jar Test

Search Result 154, Processing Time 0.03 seconds

The Improvement of Water Quality by Using Filter-aids in Rapid Sand Filters (급속모래여과 공정에서의 여과보조제에 의한 수질개선효과 연구)

  • 김형선;이규성;백영매;조춘구
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.15-24
    • /
    • 2001
  • The objective of this study it to evaluate the microbial safety in rapid sand filters adapted in most drinking water treatment plants. The potential pathogens to cause water quality problems Are presumed to be Giardia and Gryptosporidium. They look like particles in view of their size. It has been reported that if the number of particles (larger than 2 ${\mu}{\textrm}{m}$ in water) is less than 100 per mL and its turbidity is below 0.1 NTU, it is considered as a safe water in terms of pathogens. In order to achieve such a good water quality. filter-aids (chemicals) were added to the inlet-channel of filter and their effectiveness was evaluated on the basis of water quality factors such as turbidity and particle counting. This study was conducted in she three steps of experiment: jar test. pilot plant test and real water treatment plant test (P plant in seoul). The experiment reult of the P water treatment showed that cationic polyamine was the most effective in the removal of particles and turbidity at the does of 0.25 mg/L. The turbidity without filer-aids showed in the range of 0.12 ~0.17 NTU during filtration and 0.14 NTU on the average. However. with addition of polyamine, the turbidity represented below(or less than) 0.1 NTU after 20 min in the start of filtration and kept 0.08 NTU on the average. On the other hand, as for number of particles, while no filter-aids led to the range of 111 ~270 per mL and 190 on the average, addition of polydmine led to 113 per mL on talc average, and kept below100 per mL after 20 min in the start of filtration.

  • PDF

The Effects of Acupuncture at Sobu (HT8) and Haenggan (LR2) on Scopolamine-induced Cognitive Impairment in Rat Model

  • Song, Ho-Joon;Cho, Myoung-Rae
    • Journal of Acupuncture Research
    • /
    • v.35 no.1
    • /
    • pp.28-36
    • /
    • 2018
  • Background: This study investigated the effects of acupuncture at Sobu (HT8) and Haenggan (LR2) on scopolamine-induced, cognitively impaired rats. Methods: Scopolamine-treated Sprague-Dawley rats were divided into 6 groups; normal, control, HT8, LR2, HT8 + LR2 and sham group. Cognitive impairment was induced by scopolamine, in control, and then in HT8, LR2, HT8 + LR2 and sham groups. Acupuncture treatment was performed at HT8, LR2, HT8 + LR2, and a random acupoint, respectively, every other day for 2 weeks. After each treatment, behavior change was observed and the rats were sacrificed. The change in brain-derived neurotrophic factor, glutathione peroxidase, and superoxide dismutase activity was evaluated by polymerase chain reaction. Results: Latency time to target in Morris Water-Maze test for the HT8 + LR2 group showed a significant decrease compared with control (p<0.05). Target crossing times and time zone ratios in Morris Water-Maze test for HT8 + LR2 group showed a significant increase compared with control (p<0.01). In the Y-Maze test the HT8 + LR2 group showed a significant increase compared with control (p<0.05). Brain-derived neurotrophic factor, glutathione peroxidase, and superoxide dismutase, in the HT8 + LR2 group, showed a significantly increased level compared with control (p<0.05). Neural activity of acetylcholine esterase in HT8 + LR2 group showed a significant decrease compared with the control group (p<0.01), choline acetyltransferase activity in the HT8 + LR2 group showed a significant increase compared with control (p<0.05). Conclusion: Acupuncture at HT8 + LR2 restored scopolamine-induced cognitive impairment, suggesting acupuncture could be an alternative to improve cognitive function.

Studies on the surface charge and coagulation characteristics of suspended particles in the aqueous phase (수용액상에서 부유 미립자의 표면전위와 응집특성에 관한 연구)

  • 박상원;김성국;홍대일
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.363-369
    • /
    • 1999
  • This study aimed to elucidate the relationship between theoretical parameters affecting the coagulation process and the real coagulation phenomenon applied to the dye wastewater. Emphasis was placed on the effective removal of the suspend particulates. Parameters studied in this study are pH, coagulant concentration and surface potential. Optimal dosages of coagulants by the measurement of the zeta potential at lower then $25^{\circ}C$ are 5\times$10^P-3}$ M of $FeCl_3 and 1.4\times10^{-6}M of Fe_2(SO_4)_3$. The results were well agreeded with the separate Jar-test results. Emphasis was also placed on the relationship between water quality and the content of SS. It was found that the COD and DOC were reduced to 65% and 85%, respectively. The turbidity at the above condition was reduced from 300 NTU to 0~1 NTU. Efforts were made to clarify the behavior of the suspend solid as affecting the water quality. 12,000~13,000 particles/10mL in $1~50\mu$m size range particulates in the raw wastewater were reduced to 300 particle/10mL in the same range after treatment. This research has proposed the methodology to find out the optimal condition of coagulation for small scale wastewater treatment plant or chemical coagulation process.

  • PDF

Performance Evaluation of Powdered Activated Carbon (PAC) Contactor for the Removal of Organics and Taste and Odor (분말활성탄 접촉조의 맛·냄새 및 유기물 제거 효율 평가)

  • Bae, Byung-Uk;Lim, Mun-Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.585-589
    • /
    • 2010
  • In order to evaluate the performance of a powdered activated carbon (PAC) contactor, two water treatment plants (WTP) were selected as target sites. The result of tracer tests showed that the plug flow portion of a bisymmetry-type contactor (H WTP) was more than 70%. A maze-type contactor (C WTP) also had more than 70% of plug flow portion after intra-basin baffles were installed. According to the operating data of the target WTPs, there was no clear evidence that the addition of PAC contributed to the removal of organics. However, the results of jar tests, conducted with the raw water taken from the H WTP, proved that PAC could remove dissolved organic carbon (DOC) to some extent when the proper velocity gradient was maintained. It was estimated that the production rate, defined as the ratio of the operating flowrate to the design flowrate, of the C and H WTPs was only 27 and 50%, respectively. Because of these lower production rates, the mixing intensity in the contactor was much less than the designed value and, finally, the performance of the PAC contactor was much lower than what was expected.

Nutrients Transport Pathway for Watershed Impact Analysis of Livestock Wastes and its Resources (양돈 퇴, 액비의 수질환경 영향분석을 위한 영양물질 이동경로 연구)

  • Oa, Seong-Wook
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.465-470
    • /
    • 2011
  • Liquid fertilizer and composted cattle manure were applied to an agricultural land. This study was conducted to find the pathway of the nutrients transport. Nitrogen concentration was decreased by the repeatable precipitation in surface runoff, but the nitrate concentration in ground water was gradually increased by biological metabolism, especially with pig liquid fertilizer. Phosphorus was mostly adsorbed into the soil, and its reduction was affected by the soil drain by surface runoff in the summer. Averaged adsorption capacity of the phosphorus via Jar-test was determined as 21.5 mg P/kg of soil.

Conditioning and Dewatering Properties of Digested and Thickened Sludge with Inorganic Conditioner (무기개량제를 이용한 소화 및 농축슬러지의 개량 및 탈수 특성)

  • Kim, Jeong-Ho;Nam, Se-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.467-473
    • /
    • 2011
  • Objectives: Wastewater treatment plants typically produce a large volume of waste sludge. In this study, the conditioning and dewatering properties of a digested and thickened sludge from an industrial wastewater treatment plant were investigated in order to improve the dewaterbility of the sludge. Methods: Jar-tests and Buchner funnel tests were carried out to assess the conditioning and dewatering properties of a waste sludge. TTF (Time to Filter Test) and SRF (Specific Resistance to Filtration) were adopted as the indices of sludge dewaterbility. Results: The valuation indices influencing the dewaterbility of the waste sludge, including TTF, SRF, water contents, VS/TS ratio and turbidity, were measured. The TTF and SRF of the digested and thickened sludge were decreased to 40 sec, $3.43{\times}10^{12}$ m/kg, and 39 sec, $1.09{\times}10^{12}$ m/kg, respectively. Conclusions: The conditioner composed of natural inorganic materials turned out to be effective in the reduction of sludge water contents.

Fabrication of Al Flake Powder for Pigment (안료용 알루미늄 플레이크 분말 제조)

  • 홍성현;김병기
    • Journal of Powder Materials
    • /
    • v.10 no.6
    • /
    • pp.415-421
    • /
    • 2003
  • The study for producing the flake powders by milling of aluminum foil and gas atomized powders was carried out. The effects of lifter bars on the ball motions and milling of aluminum foils were also investigated. The aluminum foils were laminated each other, elongated, fragmented into small foils and finally formed into the flake powders during the dry ball-milling. The spherical atomized-powders were milled to coarse flake powders with high aspect ratio and then changed to fine flake powders with lower aspect ratio. Even though long times were required for making flake powders by milling of foils, the water covering areas of them were higher than those of powders milled using gas-atomized powders, suggesting aluminum foils were more plastically deformed by micro-forging. On the other hand, as the number of lifter bars increased, the necessary rotation speeds of milling jar for cascading mode and cataracting mode decreased drastically. It was possible to achieve same quality of milled flake powder by using the lifter bars under the lower milling speeds. The painting test showed that the appearance of painted surface was good and optimum content range of aluminum paste in car paint to maximize the degree of gloss was 3-5%.

Development of Datamining Roadmap and Its Application to Water Treatment Plant for Coagulant Control (데이터마이닝 로드맵 개발과 수처리 응집제 제어를 위한 데이터마이닝 적용)

  • Bae, Hyeon;Kim, Sung-Shin;Kim, Ye-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.7
    • /
    • pp.1582-1587
    • /
    • 2005
  • In coagulant control of water treatment plants, rule extraction, one of datamining categories, was performed for coagulant control of a water treatment plant. Clustering methods were applied to extract control rules from data. These control rules can be used for fully automation of water treatment plants instead of operator's knowledge for plant control. To perform fuzzy clustering, there are some coefficients to be determined and these kinds of studies have been performed over decades such as clustering indices. In this study, statistical indices were taken to calculate the number of clusters. Simultaneously, seed points were found out based on hierarchical clustering. These statistical approaches give information about features of clusters, so it can reduce computing cost and increase accuracy of clustering. The proposed algorithm can play an important role in datamining and knowledge discovery.

The Effects of Temperature, Coagulants, and Pre-chlorination on the Removal of Cryptosporidium and Giardia by Coagulation Process (응집침전공정에서 수온, 응집제 종류, 전염소 주입에 따른 크립토스포리 디움과 지아디아 제거 효율 변화에 관한 연구)

  • Park, Sang-Jung;Chung, Young-Hee;Chung, Hyen-Mi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.531-538
    • /
    • 2007
  • The effects of temperature, coagulants and pre-chlorination on the removal of turbidity and pathogenic protozoa by coagulation process were investigated using jar test of lab scale. In room temperature ($25^{\circ}C$), protozoa were removed over 1.0log at the proper concentration range of coagulants, and up to over 2log at the optimal concentration of coagulants. Considering the 1.5log target removal for Giardiain the processes of coagulation, sedimentation, and filtration, this results implies that the target could be satisfied. However, the removal of protozoa and turbidity was reduced, and optimal PAC concentration was narrowed in low turbidity and cold temperature ($5^{\circ}C$). These results suggest that the drop of coagulation efficiency may be occurred in winter if the conditions are not optimized. Despite the effect of water temperature, the relation of turbidity and protozoa removal appeared to be good. The various kinds of coagulants did not significantly affected for removals of turbidity and protozoa when the concentrations of $Al_2O_3$ were considered. Prechlorination did not increase or decrease the removal of turbidity and protozoa in optimum condition at room temperature, pH 7, 15mg/L of PAC concentration.

Automatic Control on Dosing Coagulant as to Stream Current

  • Oh, Sueg-Young;Byun, Doo-Gyoon;Hwang, Jae-Moon;Song, Hyun-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1318-1321
    • /
    • 2005
  • As recently raw water quality has been polluted as well as its quality has been remarkably varied according to season and region, the precise control of coagulant dosage is being keenly required in water treatment plants. The amount of coagulant is closely related to raw water quality such as turbidity, alkalinity, water temperature, pH, electrical conductivity, etc. Since the optimum quantity of chemicals is not yet finalized, so dosage rate must be decided by using jar test that takes one or two hours. Hereupon, the output signal of stream current and multi-regression on historical data were proposed to be applied to the coagulant dosing control. In consequence of applying the scheme to automatic determination of the dosage rate, it was testified that the determination of dosage rate was very effective in case it is performed as to real-time sensing of water quality and the output signal of stream current.

  • PDF