• Title/Summary/Keyword: Jang image

Search Result 1,881, Processing Time 0.034 seconds

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

Comparison of palatal bone thickness between 3D model and lateral cephalometric radiograph (성인 구개부 측모두부계측방사선 사진과 3D model의 골두께 비교)

  • Jang, Min-Guk;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Sang-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.312-323
    • /
    • 2011
  • Objective: This study compared the bone thickness of the palate between lateral cephalogram and 3D model measurements. Methods: The subjects consisted of 30 adults (15 men,15 women) with a normal skeletal pattern and occlusion. The CT images were transformed to a 3D model, and were compared with the cephalometric image. Descriptive statistics for each variable were calculated. Results: In the 3D CT model, the mid-palatal area was the thickest part. It became thinner as the palate tapered laterally. In the male group, the thinnest portion was positioned 6 mm away from the mid-palate, while in the female group the thinnest portion was 8mm away from the mid-palate. Correlation analysis between the lateral cephalometric and 3D CT model revealed a significant correlation except in the mid palatal area and the area 2 mm lateral to the mid-palate in men, whereas there was a significant relationship in every area in the women. In both men and women, the highest correlation appeared in the area 8 mm lateral to the mid palate. Conclusions: Using regression analysis, an actual prediction of the bone thickness between the measured bone thickness of the lateral cephalometric radiograph and 3D model was made. This will provide useful information for mini-implant length selection when inserting into the palate.

Digitization of Adjectives that Describe Facial Complexion to Evaluate Various Expressions of Skin Tone in Korean (피부색을 표현하는 형용사들의 수치화를 통한 안색 평가법 연구)

  • Lee, Sun Hwa;Lee, Jung Ah;Park, Sun Mi;Kim, Younghee;Jang, Yoon Jung;Kim, Bora;Kim, Nam Soo;Moon, Tae Kee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.4
    • /
    • pp.349-355
    • /
    • 2017
  • Skin tone plays a key role in one of the determinant for facial attractiveness. Most female customers have an interest in choosing skin color and improving their skin tone and their needs have been contributed the expansion of cosmetic products in the market. Recently, cosmetic customers, who want bright skin, are also interested in healthy and lively-looking skin. However, there is no method to evaluate the skin tone with the complexion-describing adjectives (CDAs). Therefore, this study was conducted to find the ways to objectify and digitize the CDA. We obtained that quasi $L^*$ at dark skin is 65 and quasi $L^*$ at bright skin is 74 for standard images, which are selected from our data base. To match the following seven CDAs: pale, clear, radiant, lively, healthy, rosy and dull, the colors of both images were adjusted by 30 panels. The quasi $L^*$, $a^*$ and $b^*$ were converted from the RGB values of the manipulated images. The differences between the quasi $L^*$, $a^*$ and $b^*$ values of standard images and manipulated images reflecting each CDA were statistically significant (p < 0.05). However, there were no statistical significances between the $L^*$ values of dark and bright skin images that were modified in accordance with each CDA and there also were no statistical significances between the quasi $a^*$ values of dark and bright skin for pale and clear CDAs. From the statistical analysis, the CDAs were observed to form three groups: (i) pale-clear-radiant, (ii) lively-healthy-rosy and (iii) dull. We recognized that people have a similar opinion about perception of CDAs. Following our results of this study, we establish new standard method for sensibility evaluation which is difficult to carry out scientifically or objectively.

Urban Building Change Detection Using nDSM and Road Extraction (nDSM 및 도로망 추출 기법을 적용한 도심지 건물 변화탐지)

  • Jang, Yeong Jae;Oh, Jae Hong;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.3
    • /
    • pp.237-246
    • /
    • 2020
  • Recently, as high resolution satellites data have been serviced, frequent DSM (Digital Surface Model) generation over urban areas has been possible. In addition, it is possible to detect changes using a high-resolution DSM at building level such that various methods of building change detection using DSM have been studied. In order to detect building changes using DSM, we need to generate a DSM using a stereo satellite image. The change detection method using D-DSM (Differential DSM) uses the elevation difference between two DSMs of different dates. The D-DSM method has difficulty in applying a precise vertical threshold, because between the two DSMs may have elevation errors. In this study, we focus on the urban structure change detection using D-nDSM (Differential nDSM) based on nDSM (Normalized DSM) that expresses only the height of the structures or buildings without terrain elevation. In addition, we attempted to reduce noise using a morphological filtering. Also, in order to improve the roadside buildings extraction precision, we exploited the urban road network extraction from nDSM. Experiments were conducted for high-resolution stereo satellite images of two periods. The experimental results were compared for D-DSM, D-nDSM, and D-nDSM with road extraction methods. The D-DSM method showed the accuracy of about 30% to 55% depending on the vertical threshold and the D-nDSM approaches achieved 59% and 77.9% without and with the morphological filtering, respectively. Finally, the D-nDSM with the road extraction method showed 87.2% of change detection accuracy.

'The Same Scenery' and 'a Different Landscape' Included in "Real-Scenery Landscape Painting", an Essay to Determine Meaning - Centering around Paintings of Chong Seok Jeong in the 18th-19th Centuries - (실경산수화에 담긴 '같은 경관' 그러나 '다른 풍경', 그 의미 찾기 - 18.19C 총석정 그림을 중심으로 -)

  • Rho, Jae-Hyun;Jang, Il-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.5
    • /
    • pp.82-93
    • /
    • 2008
  • This research focused on the process in which 'the same scenery' is recognized and represented as 'a different landscape' to determine the symbols and meaning of the scenery and landscape included in real-scenery landscape paintings of the 18th-19th centuries. As a result of analyzing the visual points, the content and expressions of 25 real-scenery landscape paintings of Chong Seok Jeong(叢石亭), it can be seen that the transmission of a kind of semiotic landscape on the basis of a specific symbol was accomplished naturally through imitation and representation for the purpose of the expression of Chong Seok Jeong-like idealized scenery. This shows that the unique images of Chong Seok Jeong have long been passed down after taking root as a unique benchmark The meaningful symbol of 'a strange Saseonbong(四仙峰)', which is broken by the spray after rising high, and 'a pine forest' have both been transmitted as being in the manner of Chong Seok Jeong. This has been equipped with the stereo-type scene by being a collective symbolization as the psycho-scenes in memory element of Chong Seok Jeong. Through the pictures of both Gyeomjae(謙齋) and Danweon(檀園), the process by which a specific painter's pictures become acculturated is highly interesting. The scenery expressed in these pictures was clearly that of a landscape of which its particularly emotions and remembrances were repainted through the experience of several places and original sketches. This can be explained as the concept in which the image from 'a specific scenery' gained through actual experience, that is, a personal feeling, has been expressed. The picture that was expressed as a different figure even at the same visual point for the same scenery is the result that was redefined through the scenery subject's recognition. Also, the modification of the scenery object can be colorful through meditation and Sachu(邪推: guessing with wicked doubt). The scenery recognized newly through adoption, omission and emphasis, it is 'the specific scenery' in the heart and is a figure having been more similar to 'a landscape' if the objective life reproduction before being acculturated is a figure similar to the scenery. So, the concept looks like being very persuasive that 'the nature with objectivity captured sensuously' simply is the scenery, and that 'the subjective phenomenon having acquired the cultural nature by being introspected in the method of aesthetic nostalgia is a landscape'.

THE CHANGE OF CANAL CONFIGURATION AFTER INSTRUMENTATION BY SEVERAL NICKEL-TITANIUM FILES IN THE SIMULATED CANAL WITH ABRUPT CURVATURE (수종의 엔진구동형 니켈-타이타늄 파일에 의한 급한 만곡의 근관 성형시 근관형태 변화에 대한 비교연구)

  • Lim, Jung-Jang;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.303-311
    • /
    • 2005
  • The purpose of this study was to evaluate which type of Ni-Ti files are able to maintain canal configuration better in the simulated canal with abrupt curvature near it's apex. Ninety six simulated root canals were made in epoxy resin and $\sharp$15 finger spreader was used as root canal templates. The simulated root canals were made with radius of curvature of 1.5mm, 3.0mm, 4.0mm, 6.0mm respectively and the angle of curvature of all simulated canals were adjusted to 90 degree. The simulated canals were instrumented by ProFile, ProTaper, Hero 642, and $K^3$ at a 300 rpm using crown-down pressureless technique. Pre-instrumented and post-instrumented images were taken by digital camera and were superimposed with Adobe Photos hop 6.0 program. Images were compared by image analysis program. The changes of canal width at the inner and outer side of the canal curvature. canal transportation were measured at 9 measuring point with 1 mm interval. Statistical analysis among the types of Ni-Ti files was performed using Kruskal-Wallis test and Mann-Whitney U-test. The result was that ProFile maintain original canal configuration better than other engine driven Ni-Ti files in the canals above 3.0mm radius of curvature, and in the 1.5mm radius of curvature, most of Ni-Ti flies were deformed or separated during instrumentation.

A Study on the Outlook of Dentists on Dental Coordinators and Their Job (치과의사의 치과 코디네이터 업무 및 인식에 관한 조사연구)

  • Yoo, Jung-Sook;Jang, Mi-Hwa;Jung, Jae-Yeon;Cho, Myung-Sook;Choi, Bu-Geun;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.201-218
    • /
    • 2005
  • The purpose of this study was to examine how dentists perceived dental coordinators including their education, hiring criteria, working condition and job. It's basically attempted to help define the job and role of 5 and to suggest how they should be nurtured. The subjects in this study were dentists at dental hospitals and clinics where dental coordinators were employed among approximately 200 dental institutions in Seoul, Cyeonggi province and Incheon. After a survey was conducted in June 2005, answer sheets from 99 respondents were analyzed. The findings of the study were as follows: 1. Regarding education for dental coordinators, 99.9% of the dentists investigated felt the need for separate education programs for dental coordinators, 42.4% knew what would-be dental coordinators learned about, and 81.8% considered it necessary for them to take intermediate or higher courses. An organization affiliated with the Korea Dental Hygienists Association was viewed as the best institute to educate dental coordinators, and educational institutes that included a department of dental hygiene was looked upon as the second best one. 68.7% believed that dental coordinators should take an official examination to test their qualifications, and concerning educational subsidy, the largest group of the dentists thought that a certain amount of subsidy should be provided. 2. As for coordinator hiring, the top priority was the impression(look) of applicants(55%), followed by adjustability to existing employees(24.5%) and professional competency(17.3%). As to the route of hiring, 41.4 percent, the largest group, reeducated some of existing employees, and dental hygienists were regarded as the best personnels to serve as a coordinator. Concerning job performance, they put the most emphasis on interpersonal relationship, which was followed by executive ability, impression and career, 58.6% the largest group, believed that dental coordinators should have a three-year or higher career to work at a dental institute. 3. As to working conditions, 75.7%, the largest group, paid dental coordinators based on their job performance, and 23.2%, the second largest group, had their pay equal to that of dental hygienists, 88.9% allowed them to determine their own retirement age. 4. In regard to their perception of dental coordinators, the largest number of the dentists considered it necessary for them to keep receiving education(4.29), and the second largest group felt that they served to enhance the image of dental institutes(4.18). The third largest group thought that they contributed to letting patients more satisfied with the quality of dental services. But they tended not to agree that their turnover rate was low(3.04), and they didn't find them to receive appropriate education, either(3.10). 5. The current major job of coordinators associated with customer services was handling appointments with customers(91.9%), treating unsatisfied customers(85.9%), and controling waiting time(84.8%). Regarding self-management, coordinators directed their energy into having good manners(89.9%), acquiring fundamental dental knowledge(84.8%), and learning how to treat customers(83.8%). Concerning hospital affairs handling, they were most responsible for information desk(87.9%), which was followed by receiving(86.9%). As a result of investigating what type of job the dentists hoped dental coordinators to fulfill in consideration of their career, their age and type of investment, the dentists wanted them the most to speak a foreign language, which belonged to the field of self-management.

  • PDF

Evaluation of Usefulness of Iterative Metal Artifact Reduction(IMAR) Algorithm In Proton Therapy Planning (양성자 치료계획에서 Iterative Metal Artifact Reduction(IMAR) Algorithm 적용의 유용성 평가)

  • Han, Young Gil;Jang, Yo Jong;Kang, Dong Heok;Kim, Sun Young;Lee, Du Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Purpose: To evaluate the accuracy of the Iterative Metal Artifact Reduction (IMAR) algorithm in correcting CT (computed tomography) images distorted due to a metal artifact and to evaluate the usefulness when proton therapy plan was plan using the images on which IMAR algorithm was applied. Materials and Methods: We used a CT simulator to capture the images when metal was not inserted in the CIRS model 062 Phantom and when metal was inserted in it and Artifact occurred. We compared the differences in the CT numbers from the images without metal, with a metal artifact, and with IMAR algorithm by setting ROI 1 and ROI 2 at the same position in the phantom. In addition, CT numbers of the tissue equivalents located near the metal were compared. For the evaluation of Rando Phantom, CT was taken by inserting a titanium rod into the spinal region of the Rando phantom modelling a patient who underwent spinal implant surgery. In addition, the same proton therapy plan was established for each image, and the differences in Range at three sites were compared. Results: In the evaluation of CIRS Phantom, the CT numbers were -6.5 HU at ROI 1 and -10.5 HU at ROI 2 in the absence of metal. In the presence of metal, Fe, Ti, and W were -148.1, -45.1 and -151.7 HU at ROI 1, respectively, and when the IMAR algorithm was applied, it increased to -0.9, -2.0, -1.9 HU. In the presence of metal, they were 171.8, 63.9 and 177.0 HU at ROI 2 and after the application of IMAR algorithm they decreased to 10.0 6,7 and 8.1 HU. The CT numbers of the tissue equivalents were corrected close to the original CT numbers except those in the lung located farthest. In the evaluation of the Rando Phantom, the mean CT numbers were 9.9, -202.8, and 35.1 HU at ROI 1, and 9.0, 107.1, and 29 HU at ROI 2 in the absence, presence of metal, and in the application of IMAR algorithm. The difference between the absence of metal and the range of proton beam in the therapy was reduced on the average by 0.26 cm at point 1, 0.20 cm at point 2, and 0.12 cm at point 3 when the IMAR algorithm was applied. Conclusion: By applying the IMAR algorithm, the CT numbers were corrected close to the original ones obtained in the absence of metal. In the beam profile of the proton therapy, the difference in Range after applying the IMAR algorithm was reduced by 0.01 to 3.6 mm. There were slight differences as compared to the images absence of metal but it was thought that the application of the IMAR algorithm could result in less error compared with the conventional therapy.

  • PDF

The Role of Air-Vacuum Cushion Device in Patients with Rectal Cancer in Radiation Therapy (직장암 환자에서 방사선치료시 Air-vacuum Cushion의 유용성)

  • Kim Ki-Hwan;Cho Moon-June;Kang No-Hyun;Kim Dong-Wuk;Kim Jun-Sang;Jang Ji-Young;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Prupose : We analyzed setup errors induced by using air-vacuum cushion as immobilization device in patients with rectal cancer. Materials and methods : We had treated the twenty patients with rectal cancer by 6 MV, 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at prone position. They were separated to two groups, control group, 10 patients using styrofoam, and test group, 10 patients using styrofoam and air-vacuum cushion. We measured errors of posterior field for x, y axis and lateral field for z, y axis with simulation film and EPID image using a matching technique. Results : In control group, the mean displacement values of pelvic bone landmark for x axis and y axis were 0.02 mm. 0.78 mm, respectively and the standard deviations of systematic error were 2.13 mm, 2.40 mm, respectively and the standard deviation of random error were 1.46 mm. 1.51 mm, respectively. In test group, the mean displacement values of x axis and y axis were -0.33 mm. 0.81 mm, respectively and the standard deviations of systematic error were 1.71 mm, 3.08 mm, respectively and the standard deviations of random errors were 1.40 mm. 1.88 mm, respectively. The mean displacement values of z axis and y axis were 2.98 mm. 0.74 mm, respectively and the standard deviations of systematic error were 4.75 mm, 2.65 mm, respectively and standard deviations of random error were 2.69 mm. 1.86 mm, respectively. The statistical difference of field size by using air vacuum cushion between two groups in posterior direction and lateral direction was not shown. Conclusion : We think that use of air-vacuum cushion may not be an advantage for improving setup accuracy in rectal cancer patients.

  • PDF

A New Item Recommendation Procedure Using Preference Boundary

  • Kim, Hyea-Kyeong;Jang, Moon-Kyoung;Kim, Jae-Kyeong;Cho, Yoon-Ho
    • Asia pacific journal of information systems
    • /
    • v.20 no.1
    • /
    • pp.81-99
    • /
    • 2010
  • Lately, in consumers' markets the number of new items is rapidly increasing at an overwhelming rate while consumers have limited access to information about those new products in making a sensible, well-informed purchase. Therefore, item providers and customers need a system which recommends right items to right customers. Also, whenever new items are released, for instance, the recommender system specializing in new items can help item providers locate and identify potential customers. Currently, new items are being added to an existing system without being specially noted to consumers, making it difficult for consumers to identify and evaluate new products introduced in the markets. Most of previous approaches for recommender systems have to rely on the usage history of customers. For new items, this content-based (CB) approach is simply not available for the system to recommend those new items to potential consumers. Although collaborative filtering (CF) approach is not directly applicable to solve the new item problem, it would be a good idea to use the basic principle of CF which identifies similar customers, i,e. neighbors, and recommend items to those customers who have liked the similar items in the past. This research aims to suggest a hybrid recommendation procedure based on the preference boundary of target customer. We suggest the hybrid recommendation procedure using the preference boundary in the feature space for recommending new items only. The basic principle is that if a new item belongs within the preference boundary of a target customer, then it is evaluated to be preferred by the customer. Customers' preferences and characteristics of items including new items are represented in a feature space, and the scope or boundary of the target customer's preference is extended to those of neighbors'. The new item recommendation procedure consists of three steps. The first step is analyzing the profile of items, which are represented as k-dimensional feature values. The second step is to determine the representative point of the target customer's preference boundary, the centroid, based on a personal information set. To determine the centroid of preference boundary of a target customer, three algorithms are developed in this research: one is using the centroid of a target customer only (TC), the other is using centroid of a (dummy) big target customer that is composed of a target customer and his/her neighbors (BC), and another is using centroids of a target customer and his/her neighbors (NC). The third step is to determine the range of the preference boundary, the radius. The suggested algorithm Is using the average distance (AD) between the centroid and all purchased items. We test whether the CF-based approach to determine the centroid of the preference boundary improves the recommendation quality or not. For this purpose, we develop two hybrid algorithms, BC and NC, which use neighbors when deciding centroid of the preference boundary. To test the validity of hybrid algorithms, BC and NC, we developed CB-algorithm, TC, which uses target customers only. We measured effectiveness scores of suggested algorithms and compared them through a series of experiments with a set of real mobile image transaction data. We spilt the period between 1st June 2004 and 31st July and the period between 1st August and 31st August 2004 as a training set and a test set, respectively. The training set Is used to make the preference boundary, and the test set is used to evaluate the performance of the suggested hybrid recommendation procedure. The main aim of this research Is to compare the hybrid recommendation algorithm with the CB algorithm. To evaluate the performance of each algorithm, we compare the purchased new item list in test period with the recommended item list which is recommended by suggested algorithms. So we employ the evaluation metric to hit the ratio for evaluating our algorithms. The hit ratio is defined as the ratio of the hit set size to the recommended set size. The hit set size means the number of success of recommendations in our experiment, and the test set size means the number of purchased items during the test period. Experimental test result shows the hit ratio of BC and NC is bigger than that of TC. This means using neighbors Is more effective to recommend new items. That is hybrid algorithm using CF is more effective when recommending to consumers new items than the algorithm using only CB. The reason of the smaller hit ratio of BC than that of NC is that BC is defined as a dummy or virtual customer who purchased all items of target customers' and neighbors'. That is centroid of BC often shifts from that of TC, so it tends to reflect skewed characters of target customer. So the recommendation algorithm using NC shows the best hit ratio, because NC has sufficient information about target customers and their neighbors without damaging the information about the target customers.