• 제목/요약/키워드: J inverter circuit

검색결과 104건 처리시간 0.022초

충전전압 가변방식을 이용한 펄스형 Nd:YAG 레이저의 출력특성에 관한 연구 (The output characteristics of pulsed Nd:YAG laser with voltage variable capacitor-charging system)

  • 문동성;홍정환;송금영;송우정;김강호;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1703-1705
    • /
    • 2001
  • The pulsed Nd:YAG laser is used widely for materials processing and medical instrument etc. It is important to control the laser energy in those fields using a pulsed Nd:YAG laser. In this paper, constant-frequency current resonant half-bridge inverter and Cockcroft-Walton circuit are used to charge the energy storage capacitor variably. This laser power supply is designed and fabricated which has no high-voltage transformer, less switching losses, compact size and capability in varying the laser output power. Also, the output characteristics of this Nd:YAG laser system are investigated. The tested results are described.

  • PDF

A Compact LTCC Dual-Band WLAN Filter using Two Notch Resonators

  • Park, Jun-Hwan;Cheon, Seong-Jong;Park, Jae-Yeong
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.168-175
    • /
    • 2013
  • This paper presents compact dual-band WLAN filter and filter module. They were developed by embedding all of the passive lumped elements into a LTCC substrate. In order to reduce the size/volume of the filter and avoid EM parasitic couplings between the passive elements, the proposed filter was designed using a 3rd order Chebyshev circuit topology and J-inverter transformation technology. The 3rd order Chebyshev bandpass filter was firstly designed for the band-selection of the 802.11b and was then transformed using finite transmission zeros technologies. Finally, the dual-band filter was realized by adding two notch resonators to the 802.11b filter circuit for the band-selection of the 802.11a/g. The maximum insertion losses in the lower and higher passbands were better than 2.0 and 1.3 dB with minimum return losses of 15 and 14 dB, respectively. Furthermore, the filter was integrated with a diplexer to clearly split the signals between 2 and 5 GHz. The maximum insertion and minimum return losses of the fabricated module were 2.2 and 14 dB at 2.4 - 2.5 GHz, and 1.6 and 19 dB at 5.15 - 5.85 GHz, respectively. The overall volume of the fabricated filter was $2.7{\times}2.3{\times}0.59mm^3$.

가동코일형 리니어 왕복 액추에이터의 동특성 (Dynamic Characteristics of Moving Coil Type Linear Oscillatory Actuator)

  • 장석명;정상섭;권철;박희창;문석준;박찬일;정태영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.180-187
    • /
    • 2000
  • A moving-coil-type linear oscillatory actuator(LOA) consists of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure. The LOA system was represented by the voltage equation of coil and the mechanical equation of motion. This set of equations was manipulated in state-space form. The EMF constant kE of equation parameters in state-space form can be obtained by using the induced voltage in armature coils at open circuit test. kE and other parameters provide the system matrices and transfer function for frequency response and dynamic simulation. Voltage source inverter-fed LOA is examined aiming to compare with results of simulation.

  • PDF

EKF를 이용한 BLDC 모터 구동기 인버터의 고장 검출 및 분리 (Fault Detection and Isolation for the Inverter of BLDC Motor Drive using EKF)

  • 김선기;성상만;강기호
    • 제어로봇시스템학회논문지
    • /
    • 제20권7호
    • /
    • pp.706-712
    • /
    • 2014
  • The inverters used to drive Brushless DC motors (BLDC) include switching devices such as FETs and the faults in FETs cause severe performance degradation in systems where a BLDC acts as actuator. This paper presents a fault detection and isolation method for the FETs of an inverter for BLDC motor control systems, which is based on the EKF (Extended Kalman filter). Firstly, an equivalent circuit model for a BLDC motor plus its inverter system was derived. Secondly, a state-space equation was established, where the on-resistance of the FETs is expressed as a state variable and the EKF equation estimates the on-resistance. If the estimated resistance differs greatly from the known value, it can be asserted that there is a fault on that FET. Thirdly, the local convergence of the established EKF was proved. Finally, through the experiments, the performance of the proposed method was verified. The results show that the on-resistance is estimated close to the value specified in the FET data sheet in normal operation, whereas the estimated resistance is a much larger value than the normal one in case an FET fault occurs. Therefore, it is confirmed that the proposed fault detection and isolation method works appropriately in real systems.

인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어 (AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System)

  • 박귀근;최재원
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

Fuzzy Technique based Chopper Control for Slip Energy Recovery System with Twelve-Pulse Converter

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.509-514
    • /
    • 2004
  • This paper introduces the modified slip energy recovery system in order to improve its power factor and to reduce harmonics of line current waveforms. Twelve pulse line commutated converter with the chopper type IGBT is applied where the chopper is applied across the DC terminal and the chopped DC is fed to the converter operating as an inverter and then passed through the wye-wye and delta-wye transformer circuit. This scheme leads to be able to adjust the speed of the motor by the duty cycle of the chopper operating in PWM mode. The fuzzy logic controller is also introduced to the modified slip energy recovery system for keeping the motor speed to be constant when the load varies. The experimental results in testing the 0.22 kW wound rotor induction motor from no-load condition to rated condition show the effectiveness of the proposed control scheme.

  • PDF

공진회로를 이용한 대용량 인버터 폴 시험설비에 관한 연구 (A test facility for Large Scale Inverter Pole Using Resonant Circuit)

  • 유현호;한영성;서인영;김대희;추진부;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.206-208
    • /
    • 2006
  • 대용량 인버터의 구성요소인 단상 인버터를 시험하는 방식에 대해 제안하였다. 단상 인버터의 설계 및 제작이 완료되면 설계상, 제작상의 문제점을 점검하여야 한다. 이를 위해서 실제 운전조건에 근사한 상태인 정격전압, 정격전류를 스위칭 하여 정격 전류를 충분히 도통하는 실험을 수행하여 성능의 검증이 필요하다. 본문에서는 단상 인버터 폴 2대를 이용한 이러한 시험조건을 제공하는 방식을 제안하였다.

  • PDF

공진용 인버터 전력 변환 장치를 이용한 플라즈마 살균효과 개선 (The improvement of sterilization effective using resonance inverter Power conversion device)

  • 김주용;김영문;권순걸;이현우;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.266-269
    • /
    • 2003
  • A sterilizer equipment by using electrical energy has merits that no process of chemical and no second environmental pollution. Also, the power conversion circuit for sterilizer equipment has merits that are reducing switching loss for soft switching topology by using zero current and zero voltage switching, and miniaturizing size of equipment. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with plasma sterilization device, to find more economical and effective way, and to suggest more improved sterilizer.

  • PDF

BLDC용 인버터를 이용한 PV 양수펌프의 MPPT 제어 (MPPT Control of PV Water Pump Using BLDC-Inverter)

  • 백승길;조정민;이승환;김성남;오봉환;이훈구;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.971-973
    • /
    • 2001
  • This paper shows how to design a Global control, using Field Orientation, avoiding to use the DC/DC converter, and finding the relationships among the DC magnitudes and AC ones. And This paper deals with water pumping system which economic and durable storage systems for sustained production of power and propose MPPT methods using $i_{qs}$ of BLDC motor without battery module and chopper circuit.

  • PDF

고속전철용 단상 PWM 컨버터에 관한 연구 (A Single Phase PWM Converter for High Speed Traction System)

  • 김연준;김두식;이현원;서광덕;김남해
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.630-633
    • /
    • 1997
  • This paper describes a design of a single phase PWM converter for high speed train. Parallel operation and control method of four Quadrant PWM converters are described. Simulation and modelling of the converters is performed. Capacity of the converter/inverter and power circuit for high speed traction system designed. And harmonic contents of AC line current's are analyzed. The results of the simulation are presented.

  • PDF