• Title/Summary/Keyword: J 적분법

Search Result 83, Processing Time 0.021 seconds

Numerical Simulation of Liquid Sloshing in Three- Dimensional Tanks (3차원(次元) 탱크내에서의 액체(液體) 슬로싱의 수치(數値) 해석(解析))

  • J.H. Hwang;I.S. Kim;Y.S. Seol;S.C. Lee;Y.K. Chon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.1
    • /
    • pp.12-18
    • /
    • 1991
  • Three-dimensional nonlinear sloshing effects due to tank motions are simulated by solving boundary value problem using the panel method based on boundary integral technique. While Shinkai used boundary elements on which source strengths vary linearly between nodes, the source of constant strength is distributed on each triangular panel in the present study. The source strength at each time step is determined by solving the Fredholm integral equation of the second kind obtained from Green's theorem. To avoid cumulative numerical errors as time elapses, Adam-Bashforth-Moulton method is employed. Numerical examples for the case of partially filled spherical tank on board oscillating in harmonic sway mode or pitch mode are solved. The elevation of the free surface is compared with the result by Shinkai and confirmed in good agreement during early time. The input and the output energy are comparatively evaluated to check the overall accuracy of the present numerical scheme. Although some leakage of energy are found as time marches, it is plausible when we take into account nonlinearities of the problem and the number of panels of the model.

  • PDF

Development of Gait Distance Measurement System Based on Inertial Measurement Units (관성측정장치를 이용한 보행거리 측정 시스템 개발)

  • Lee, K.H.;Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.161-168
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait distance measurement system using accelerometer, gyroscope, and magnetometer. To minimize offset and gain error of inertial sensors, we performed the calibration using the self-made calibration jig with 9 degrees of freedom. For measuring accurate gait distance, we used gradient descent algorithm to remove gravity error and used analysis of gait pattern to remove drift error. Finally, we measured a gait distance by double-integration of the error-removed acceleration data. To evaluate the performance of our system, we walked 10m in a straight line indoors to observe the improvement of removing error which compared un-calibrated to calibrated data. Also, the gait distance measured by the system was compared to the measurement of the Vicon motion capture system. The evaluation resulted in the improvement of $31.4{\pm}14.38%$(mean${\pm}$S.D.), $78.64{\pm}10.84%$ and $69.71{\pm}26.25%$ for x, y and z axis, respectively when walked in a straight line, and a root mean square error of 0.10m, 0.16m, and 0.12m for x, y and z axis, respectively when compared to the Vicon motion capture system.

  • PDF

Analysis of Signal Properties in accordance with electrode area of x-ray conversion material (X선 검출 물질의 전극 면적에 따른 신호특성 분석)

  • Jeon, S.P.;Kim, S.H.;CHO, K.S.;Jung, S.H.;Park, J.K.;Kang, S.S.;Han, Y.H.;Kim, K.S.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.5-9
    • /
    • 2010
  • In recent, a digital x-ray detector attracted worldwide attention and there are many studies to commercialize. There are two methods in digital x-ray detector. This method is an Indirect method and Direct method. This study is to see the differences between the digital x-ray detector based on a-Se used in the existing indirect conversion method and an x-ray conversion material that has better SNR(Signal-to-noise ratio) and property than the a-Se. To solve the problem that is difficult to make a large area film using Screen-Print method, we used a Screen-Print method. In this study, we used a polyclystal $HgI_2$ as x-ray conversion material and a sample thickness is $150{\mu}m$ and an area is $3cm{\times}3cm$. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a Magnetron Sputtering System and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$ and then we evaluated darkcurrent, sensitivity and SNR of the $HgI_2$ film are measured, then we evaluated the electrical properties. And we used a current integration mode when I-V test. This experiment shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high darkcurrent. Through fabricating of various thicknesses and optimal electrodes, we will optimize SNR in the future work.