• Title/Summary/Keyword: Isothermal Chamber

Search Result 20, Processing Time 0.023 seconds

Characteristics Measurement of Pneumatic Elements Using Isothermal Chamber (등온화용기를 이용한 공기압 기기의 성능계측)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • In this study, methods for the characteristics measurement of pneumatic elements using isothermal chamber, the methods for the flow rate and dynamic characteristic measurement of pneumatic control valve, are proposed. An isothermal chamber is a chamber in which the steel wool is stuffed and isothermal condition can almost be realized. Therefore, the instantaneous flow rate could be measured only from the pressure response using the state equation of gas. Effectiveness and simplicity of the proposed method are confirmed by comparing the measured results obtained by proposed methods with the methods defined JIS and the ISO standards.

  • PDF

A Study on the Simulation of Leak Flow-rate Using Isothermal Chamber (등온화용기를 이용한 누설유량 시뮬레이션에 관한 연구)

  • Ji, S.W.;Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.71-75
    • /
    • 2010
  • Leak detection technology is a challenging research until nowadays, because it has wide and various applications in industry. Furthermore pneumatic component reliability test based on ISO requires air leakage measurement. The conventional measurement methods need a complex operation and the calibration of leak detector. Tracing the history of our study, we proposed a new method for measurement of leak flow rate using isothermal chamber. In this study, propose a simulation model of isothermal chamber by infinitesimal flow -rate, such as a leak flow-rate. The effectiveness of the proposed simulation model is proved by simulation and experimental results. Base on the comparison results, proposed simulation model is good agreement with experimental results.

An Isothermal Temperature Source with a Large Surface Area using the Metal-Etched Microwick-Inserted Vapor Chamber Heat Spreader

  • Go, Jeong-Sang;Kim, Kyung-Chun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.681-688
    • /
    • 2004
  • For use of the thermal cycle of the biochemical fluid sample, the isothermal temperature source with a large surface area was designed, fabricated and its thermal characterization was experimentally evaluated. The comprehensive overview of the technology trend on the temperature control devices was detailed. The large surface area isothermal temperature source was realized by using the vapor chamber heat spreader. The cost-effectiveness and simple manufacturing process were achieved by using the metal-etched wick structure. The temperature distribution was quantitatively investigated by using IR temperature imaging system at equivalent temperatures to the PCR thermal cycle. The standard deviation was measured to be within 0.7$^{\circ}C$ for each temperature cycle. This concludes that the presented isothermal temperature source enables no temperature gradient inside bio-sample fluid. Furthermore it can be applied to the cooling of the electronic devices due to its slimness and low thermal spreading resistance.

Design and Building of Flow-rate Measurement Apparatus for Compressible Fluid (압축성유체 유량계측장치 설계 및 제작)

  • Ji, S.W.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.10 no.4
    • /
    • pp.29-33
    • /
    • 2013
  • Pneumatic system is widely applied in various industry because it have a many advantage(low cost, high safety, etc..). For design of pneumatic system, accurate flow measurement is required. In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Therefore, it can be measured for flow-rate using pressure response of isothermal chamber. As a result, this apparatus can be measured for sonic conductance and critical pressure ratio of pneumatic components and it required less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.

A Study on the Measurement Method of Leakage for Pneumatic Cylinder (공기압실린더의 누설유량 계측에 관한 연구)

  • Jang, J.S.;Ji, S.W.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.98-102
    • /
    • 2007
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing the steel wool into it. Therefore, a wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder (공압실린더의 누설유량 계측방법에 관한 연구)

  • Jang J.S.;Ji S.W.;Jeong J.H.;Kang B.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

A Study on Chamber Design for the Efficient Preservation of a Small Amount of Archives (소량 기록물의 효율적 보존을 위한 보존챔버 설계에 관한 연구)

  • Bong, Choon-Keun;Park, Seong-Jin;Lee, Jeong-Joo;Shin, Hyun-Chang
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.13 no.1
    • /
    • pp.35-58
    • /
    • 2013
  • The archives preservation chamber is an equipment that is able to store important archives with air-cleaning and isothermal-isohumidity control functions to permanently store archives in a highly safe environment. The chamber can only store small amounts of archives but it is crucial for organizations preserving archives to economically store a variety of archives, be it a medium or a small amount of documents. An arm of this study researches the current preservation status of the local record center to determine the need for such a chamber. In addition, in order to improve the air-cleaning and isothermal-isohumidity functions, the researchers of this study have conducted analyses to design the core parts. The preservation chamber that had been designed includes an archives preservation area, air-cleaning equipment, and environment measurement equipment. A preservation chamber is used to preserve small amounts of important archives safely. Thus, when a local record center is preserving various types of archives in small or medium quantities in a stack room, the preservation chamber can be used to aid their long-term preservation.

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

A Study on the Performance Improvement of an Air Spring System (에어스프링 시스템의 성능 개선에 관한 연구)

  • Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2013
  • This study describes a method which can attenuate reaction force effectively for an air spring system composed of an air spring and auxiliary chamber. For the analysis, the nonlinear governing equation of the air spring system is derived. For a performance improvement of the system, change of the heat transfer effect and the mass flow rates is included in the analysis of the air spring system. The simulation study is presented to show the reaction force is changed by variations in heat transfer characteristics and the air spring system of isothermal process has the best performance. As a result, to improve attenuation characteristics of reaction force, a process in the air spring system should be maintained near isothermal process.