• Title/Summary/Keyword: Isolation tube

Search Result 78, Processing Time 0.023 seconds

Comparison of Performance between Regular Drilled Shaft and Isolation Tube Drilled Shafts (일반 현장 타설 말뚝과 분리형 현장 타설 말뚝의 거동 비교)

  • Kim, Myung-Hak;O'Neill, Michael W.
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.211-220
    • /
    • 2000
  • An experimental study that included detailed observation of four 305-mm-diameter drilled shafts, one reference shaft of standard design and three test shafts with isolation tubes to mitigate skin friction in the vadose zone of a clay soil profile, is described. The shafts were loaded only by naturally expanding and contraction soil over a period of 17 months. The soil at the test site was instrumented to track suction and elevation changes. Maximum ground surface movements exceeding 40 mm were observed. Heave movements of less than 1.5 mm were observed in the test shafts with isolation tubes, while movements of 5 mm were observed in the reference shaft. Unit side shear loads in the shafts protected by the isolation tubes were minimal compared to those measured in the reference shaft. This indicates that the isolation tubes were very effective.

  • PDF

HEATING FLOOR FOR POULTRY : THEORETICAL AMD TECHNOLOGICAL INVESTIGATIONS

  • Narushin, Valery G.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1090-1100
    • /
    • 1996
  • Heating floor is the most profitable system of air heating at poultry houses. THe tubes with heating elements inside are laid into the layer of concrete. To prevent lossese of heat penetration deep into the ground the layer of isolation material is laid below the tubes . The depth of isolation laying in every point of the heating floor may be calculated according to the author's formula using the data of temperature on the floor surface and the tube, the distance between tow nearest tubes, and the distance between the tube and the floor surface. Technological investigations allow to estimate the optimal density for greese and ducks when they are bred on the heatuing floor.

  • PDF

New Methods for Isolation of Sesquiterpene from Panax ginseng (인삼 Sesquiterpene의 새로운 분리방법)

  • 위재준;신지영
    • Journal of Ginseng Research
    • /
    • v.21 no.3
    • /
    • pp.214-218
    • /
    • 1997
  • New simple methods for the Isolation of sesquiterpenes from Panax ginseng were developed. First, volatile compounds were isolated by simultaneous distillation and extraction (SDE) with 30% methanol and $\alpha$-hexane instead of water and ethyl ether/pentane (1:1). Secondly, head space volatiles in U-shaped tube at 7$0^{\circ}C$ were passed through C18 Sep-Pak by nitrogen gas streaming and the adsorbed volatiles were fluted by $\alpha$-hexane. TLC analysis showed that the volatile concentrates consisted mainly of terpenes when colored by vanillin-sulfuric and. GC/MS data revealed that approximately 30 sesquiterpenes of molecular weight 204 occupied 81.1% or more of the volatile concentrates isolated by those two newly developed methods. Among these, alloaromadendrene, germacrene B, isocaryophyllene, $\alpha$-neoclovene, ${\gamma}$-muurolene, $\beta$-panaslnsene, and $\alpha$-humulene were identified as being major sesqulterpenes by authentic samples or literatme search Key words : Panax ginseng, volatile compound, sesquiterpene, isolation, new method, GC/MS.

  • PDF

CFCs 조사를 위한 지하수 시료채취방법 비교 및 평가

  • 고동찬;이대하;성현정;강철희;고경석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.21-23
    • /
    • 2002
  • Two sampling methods for chlorofluorocarbons(CFCs) in groundwater were compared and assessed with groundwater samples in Jeju Island. CFCs concentrations from copper tube method were widely variable among triplicates and higher than those from flame-sealed glass ampule method. For the copper tube method, this is aggravated by rubber packings in the faucet of discharge line of wells, which was removed for the glass ampule method. The poor reproducibility and apparent contamination of results by copper tube method is due to the improper sealing of copper tubes and materials in water discharge line. This suggests that it is more difficult to achieve complete isolation from the atmosphere in the copper tube method and that materials that could release CFCs should be avoided along the sampling flow lines. It seems that the flame-sealed glass ampule method is more relevant for groundwater sampling for CFCs though it requires more complicated equipments and procedures.

  • PDF

On Prediction of Ground Heave and the Performance of the Isolation-tube Shafts (지반 괭창량 예측과 분리형 현장 타설 말뚝의 거동)

  • 김명학
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.111-128
    • /
    • 1998
  • An experimental study, which included four 305mm-diameter test shafts, one reference shaft with standard design and three test shafts with isolation tubes, is described. The soil was also soil heave and shrinkage that occur during suction changes at the field site. The test shafts were monitored for a period of about 18 months. Maximum ground movements exceeding 35mm were observed. Movements of only 1 to 2mm were observed in the test shafts with isolation tubes, while movements of 4 to 5mm were observed in the reference shaft. A simple computing model was developed to predict, based on suction changes, the maximum amount of ground heave. Relationship among suction. total stress, and volumetric strain was abtained in the laborstory. This relationship, used as inputs to the predictive model, enabled the computation of the maximum ground heave.

  • PDF

Behavior of Geotextile Tube by Plane Strain Analysis and 3-Dimensional Finite Element Method (평면변형해석과 3-D FEM 기법을 통한 지오텍스타일 튜브의 거동해석)

  • 신은철;오영인
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.233-241
    • /
    • 2003
  • Geotextile tube is hydraulically filled with dredged materials and has been applied to coastal protection and scour protection, dewatering method of slurry, and isolation of contaminated material. Recently, geotextile tube technology is no longer alternative construction technique but suitable desired solution. In this paper, the numerical analysis was performed to investigate the behavior of geotextile tube with various properties of geotextile sheet and hydraulic pumping conditions. Numerical analysis was executed to compare with the results from the large-scale field model tests, and also with those of plane strain analysis and 3-D FEM analysis. A geotextile tube was modeled using the commercial finite element analysis program ABAQUS and the one-quarter of tube was modeled. Behavior of geotextile tube during the hydraulic pumping procedure was analyzed by comparing the large-scale field model test and numerical analysis. The shape variation and maximum tube height between the numerical analysis results and large-scale filed test results are turned out to be in a good agreement.

Thermal Design of Cryogenic Compressor with Strategies for Keeping Performance of Micro-vibration Isolation System (미소진동저감용 진동절연기의 성능유지를 위한 극저온 냉각용 압축기 조립체 열제어 설계)

  • Oh, Hyun-Ung;Lee, Kyung-Joo;Jeong, Suk-Yong;Shin, So-Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.237-242
    • /
    • 2012
  • Spaceborne pulse tube-type cryogenic compressors are widely used for space applications. To guarantee cooling performance of the compressor, mission life time and micor-vibration stability, suitable thermal control of compressor is required. Micro-vibration of the compressor is the one of the sources to degrade the pointing performance of observation satellite. In the present work, on-orbit thermal design of compressor in order not to degrade the performance of micro-vibration isolation system keeping the thermal control performance has been proposed and investigated through thermo-mechanical analysis.

On-orbit Micro-vibration Isolation Performance Verification for Spaceborne Cryocooler Passive Vibration Isolator Using SMA Mesh Washer (SMA 메쉬 와셔를 적용한 우주용 냉각기 수동형 진동절연기의 궤도 미소진동 절연성능 검증)

  • Kwon, Seong-Cheol;Jeon, Su-Hyeon;Oh, Hyun-Ung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.24-32
    • /
    • 2015
  • Pulse tube-type spaceborne cryocooler is widely used to cool down the infrared sensor of observation satellites. However, such cryocooler also generates micro-vibration which is the one of main sources to seriously affect the image quality during its on-orbit operation. Therefore, to comply with the mission requirement of high resolution observation satellite, additional technical efforts have been required. In this study, we proposed a spaceborne cryocooler passive vibration isolator using SMA mesh washer, which guarantees the structural safety of both the micro-vibration disturbance source and itself under harsh launch vibration loads without an additional holding mechanism and the micro-vibration isolation performance on orbit environment. To verify the micro-vibration isolation performance of the proposed vibration isolator, we performed the micro-vibration isolation measurement test using the dedicated micro-vibration measurement device proposed in this study.

Isolation and Identification of a Purple, Non-Sulfur Bacterium from Korea Coast

  • Cha, Mi-Seon;Kim, Gi-Han;Son, Hyeong-Sik;Lee, Na-Eun;Lee, Jeong-Eun;Jo, Sun-Ja;Lee, Sang-Jun
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.409-411
    • /
    • 2003
  • A species of facultative photo-organotrophic, purple, non-sulfur bacterium was isolated from the west coast and the south coast 47 area of Korea at 2001 September. Separated 13 samples of changes with red color under $28{\sim}32\;^{\circ}C$, 3000 lux, anaerobe conditions for 7 days cultivated in Basal medium. For a pure isolation from 13 samples it used agar-shake tube method (0.4 % agar) and it separated 5 strains through 13-repetition test. The RAPD(Random Amplified Polymorphic DNA)-PCR result of strains (EGH-9, EGH-13, EGH-23, EGH-24, EGH-30) that EGH-24 and EGH-30 was same strain. For wastewater biodegradation test that 4 isolation strains cultivated in synthesis wastewater in 7 days. EGH-24 was high 63000 mg/L (CODcr) to 43400 mg/L (CODcr). EGH-24 was selected with efficient wast water treated strain. Based on the results obtained from morphology, nutrient requirements, major bacteriochlorophyll content, 165-rDNA phylogenetic analysis, this strain may be identified as a new strain of the genus Rhodobacter and named Rhodobacter sp. EGH-24.

  • PDF