• 제목/요약/키워드: Isolation frequency

검색결과 760건 처리시간 0.036초

정밀기기가 탑재된 방진대의 주파수성형 슬라이딩모드 제어 (Frequency-shaped Sliding Mode Control of Isolation Table Equipped with Precision devices)

  • 김효준;박영필
    • 한국소음진동공학회논문집
    • /
    • 제12권2호
    • /
    • pp.124-131
    • /
    • 2002
  • This paper presents the design of an active vibration suppression controller for an air-spring type vibration isolation table. Firstly, isolation system model is constructed considering the isolation table, attached equipment and voice-coil actuator. An active control system is designed based on frequency-shaped sliding mode control theory rewarding high frequency uncertainties with respect to attached equipments on the isolation table. Finally. the performance of the active isolation system is evaluated by simulation under some disturbance conditions which are transmitted from base structure of the isolation system.

수동형 RFID 시스템 적용을 위한 Isolation 개선 방법 (A Method to Improve Isolation for Passive RFID Applications)

  • 김재권;범진욱
    • 전자공학회논문지CI
    • /
    • 제44권4호통권316호
    • /
    • pp.45-49
    • /
    • 2007
  • 송신 시스템과 수신 시스템에 동일한 주파수를 사용하는 pulse-modulated 방식의 RFID (Radio Frequency IDentification) 시스템에서 송신 시스템과 수신 시스템 사이의 isolation특성은 중요한 문제점이다. 제안된 방법은 송신 시스템에 스위치와 믹서 오실레이터를 사용하여 RFID 시스템의 송신 시스템과 수신 시스템 사이의 isolation 특성을 개선하였다. 제안된 시스템은 송신 시스템에서 up-convert된 출력 신호와 수신 신호의 주파수를 다르게 하여 isolation 특성을 개선한 것이다. 이 방법을 사용하여 20 dB의 isolation 특성 개선 효과를 얻었다.

Overview of the development of smart base isolation system featuring magnetorheological elastomer

  • Li, Yancheng;Li, Jianchun
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.37-52
    • /
    • 2019
  • Despite its success and wide application, base isolation system has been challenged for its passive nature, i.e., incapable of working with versatile external loadings. This is particularly exaggerated during near-source earthquakes and earthquakes with dominate low-frequency components. To address this issue, many efforts have been explored, including active base isolation system and hybrid base isolation system (with added controllable damping). Active base isolation system requires extra energy input which is not economical and the power supply may not be available during earthquakes. Although with tunable energy dissipation ability, hybrid base isolation systems are not able to alter its fundamental natural frequency to cope with varying external loadings. This paper reports an overview of new adventure with aim to develop adaptive base isolation system with controllable stiffness (thus adaptive natural frequency). With assistance of the feedback control system and the use of smart material technology, the proposed smart base isolation system is able to realize real-time decoupling of external loading and hence provides effective seismic protection against different types of earthquakes.

운전자용 의자의 부강성 진동 절연 시스템 (Vibration Isolation System for Driver's Seats with Negative Stiffness)

  • 박성태;이상주
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.114-121
    • /
    • 2010
  • As a vehicle speed increases, more vibration energy is transmitted from chassis to a driver. Current isolation system for the driver's seat by damping control can reduce the transmitted vibration energy near resonance area. But in higher frequency region than natural frequency multiplied by $\sqrt{2}$, the vibration energy transmitted to the driver has a tendency to be increased. Therefore, the method by natural frequency reduction of the system is preferred to increase the effectiveness of the anti-vibration. However, the natural frequency could not be freely reduced due to the nature of the isolation system structure. A new passive suspension system to reduce the natural frequency is proposed. The theoretical analysis and experimental results show better vibration attenuation compared with the current isolation system.

Vibration characteristic of rubber isolation plate-shell integrated concrete liquid-storage structure

  • Cheng, Xuansheng;Qi, Lei;Zhang, Shanglong;Mu, Yiting;Xia, Lingyu
    • Structural Engineering and Mechanics
    • /
    • 제81권6호
    • /
    • pp.691-703
    • /
    • 2022
  • To obtain the seismic response of lead-cored rubber, shape memory alloy (SMA)-rubber isolation Plate-shell Integrated Concrete Liquid-Storage Structure (PSICLSS), based on a PSICLSS in a water treatment plant, built a scale experimental model, and a shaking table test was conducted. Discussed the seismic responses of rubber isolation, SMA-rubber isolation PSICLSS. Combined with numerical model analysis, the vibration characteristics of rubber isolation PSICLSS are studied. The results showed that the acceleration, liquid sloshing height, hydrodynamic pressure of rubber and SMA-rubber isolation PSICLSS are amplified when the frequency of seismic excitation is close to the main frequency of the isolation PSICLSS. The earthquake causes a significant leakage of liquid, at the same time, the external liquid sloshing height is significantly higher than internal liquid sloshing height. Numerical analysis showed that the low-frequency acceleration excitation causes a more significant dynamic response of PSICLSS. The sinusoidal excitation with first-order sloshing frequency of internal liquid causes a more significant sloshing height of the internal liquid, but has little effect on the structural principal stresses. The sinusoidal excitation with first-order sloshing frequency of external liquid causes the most enormous structural principal stress, and a more significant external liquid sloshing height. In particular, the principal stress of PSICLSSS with long isolation period will be significantly enlarged. Therefore, the stiffness of the isolation layer should be properly adjusted in the design of rubber and SMA-rubber isolation PSICLSS.

Miniaturized Radio Frequency Choke Using Modified Stubs for High Isolation in MIMO Systems

  • Lim, Seonho;Choi, Woo Cheol;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • 제15권4호
    • /
    • pp.219-223
    • /
    • 2015
  • In this paper, a miniaturized radio frequency choke (RFC) using modified stubs is proposed to improve isolation characteristics in a multiple-input-multiple-output (MIMO) antenna system. The proposed RFC, based on the LC resonance, is designed to suppress the leakage current that leads to the degradation of antenna diversity performances in the MIMO antenna configuration. The proposed RFC is composed of two open stubs that are implemented on the top of the ground plane and miniaturized by adding a slit structure on the ground plane. The MIMO antennas are also designed to verify isolation performance in the LTE 2300 band (2,300-2,400 MHz). The MIMO antennas perform well with low reflection coefficient characteristics and high isolation characteristics in the whole LTE 2300 band. To evaluate the isolation in the MIMO system, the envelope correlation coefficient (ECC) is calculated, and the value is less than 0.08. The achieved ECC is regarded as a reasonable result for improving isolation performance in the frequency range of 2,300-2,400 MHz; also, radiation patterns of antenna elements are maintained regardless of the presence of RFC.

주파수 해석을 이용한 유도전동기의 고장 검출 및 분류 (Frequency analysis based fault detection and isolation of induction motors)

  • 신필재;이인수;전기준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.702-705
    • /
    • 1996
  • Recently, induction motors are used more widely because of their low cost and simple structure. Therefore, the importance of fault detection and isolation of induction motors significantly increases. In most case the line current is used for fault detection and isolation. But in case that an induction motor has an inverter for control, it distorts the information of faulty state included in the line current. This paper proposes a new method for fault detection and isolation of induction motors that is speed controlled by the inverter using frequency analysis of the reference current instead of the line current for fault detection and isolation.

  • PDF

전자석 액츄에이터에 의한 수동방진 테이블의 제어 (Vibration control of the vibration isolation system using the electromagnetic actuator)

  • 최현;이정윤
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.227-232
    • /
    • 2003
  • As the most precision equipment requiring very strict vibration environment are vulnerable to the surrounding vibration condition, they adapt the passive or active vibration isolation system. When it comes to the passive isolation system, the resonance of the isolation system causes excessive resonance response, and finally results in the degrade the equipment performance. This paper deals with the active control method to control this resonance induced response, and includes the experiment on the active control for controlling the resonance response on the table against the excitation of the same frequency with the natural frequency of the isolation system. The electromagnetic actuator was designed and the control effect was verified by the experiment. The experiment showed that the electromagnetic actuator is effective for controlling the low frequency isolation resonance response of the precision equipment.

  • PDF

대형 잔향실의 방진 설계 및 검증 (Vibration Isolation System of a Large Reverberation Chamber)

  • 김영기;김홍배;이동우;우성현;문상무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1026-1031
    • /
    • 2003
  • A vibration isolation system fur a large reverberation chamber (1,228㎥, 1,000ton) has been installed. The reverberation chamber generates loud noise and induces high level of vibration to perform spacecraft acoustic environmental tests. The isolation system prevents vibration transfer from the chamber to enclosure buildings. This paper describes logical design process and commissioning experiments of the system. Design criteria have been induced from rigid body model of the chamber. Finite element model has been employed to select the characteristics of rubber pads. A total of 21 rubber pads have been installed between the chamber and supporting pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. Absolute transmissibility has been measured while generating 145㏈ in the chamber. The natural frequency of the chamber is 10.5㎐, which is 80% of estimated value. Overall transmissibility at working frequency range (25㎐-10,000㎐) is less than -6㏈.

  • PDF

Morphological Diversity of Marine Microorganisms on Different Isolation Media

  • Lee, Hong-Kum;Park, Shin-Hye;Kwon, Kae-Kyoung;Lee, Deuk-soo
    • Journal of Microbiology
    • /
    • 제40권2호
    • /
    • pp.161-165
    • /
    • 2002
  • Isolation frequency of microorganisms from marine sources was examined with different media and samples collected from the coastal area of Cheju Island. From sea water samples, about 1% of microorganisms from the total number of bacteria were recovered. Microorganisms were cultured at the much lower frequency of 10$\^$-4/-10$\^$-6/ from other marine sources such as sediment, sponges and corals. The frequency of duplicated isolation was examined with 140 morphologically different colonies isolated on different media. Fourteen percent of them exhibited the same morphology on two different media. The duplication frequency of the isolates among three different media was 33%.