• 제목/요약/키워드: Isolation efficiency

검색결과 308건 처리시간 0.027초

마찰진자형 Isolator의 특성 및 구조물 적용 실험연구 (An Experimental Study on Characteristics of Friction Pendulum Isolation Bearings and Its Application to a Structure)

  • 김영중;허영철;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.356-363
    • /
    • 2001
  • The friction pendulum type seismic isolation system (FPS) using the PTFE based materials has been developed to provide a simple and effective way to achieve earthquake resistance for buildings. PTFE matrials are soft and apt to be deformed easily after a few working cycles. Instead of the usual PTFE materials, the Polyimide material was used in this research. Polyimide is harder than PTFE, but has smaller friction coefficient and longer duration fur usage. In this paper, various kinds of PTFE materials were tested to define the frictional characteristics compared with the Polyimide material. FPS was manufactured with fine surface roughness and used with Polyimide material to show the seismic isolation efficiency, and life duration when applied to a rigid mass model and a 5 stole frame model.

  • PDF

중저진 지역에서의 지진격리교량의 경제적 효율성에 관한 연구 (Cost Effectiveness of Bse-Isolation for Bridges in Low and Moderate Seismic Region)

  • 고현무
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.178-185
    • /
    • 1999
  • Minimum life-cycle cost helps to evaluate cost effectiveness of base-isolated bridges under specific condition. Life-cycle cost mainly consists of the initial construction cost and the expected damage cost. Damage cost estimation needs proper model of input ground motion failure probability evaluation method and limit states definition. We model the input ground motion as spectral density function compatible with the response spectra defined at each seismicity and site condition. Spectrum analysis and crossing theory is suitable for reseating calculation of failure probabilities in the process of cost minimization. Limit states of base-isolated bridges re defined for superstructure isolator and pier respectively The method is applied to both base-isolated bridges and conventional bridges under the same conditions to investigate cost effectiveness of base isolation in low and moderate seismic region. the results show that base-isolation of bridges are more effective in low and moderate seismic region and that the site effects on the economical efficiency may not be negligible in such a region.

  • PDF

다이버시티 안테나의 소형화와 격리도 향상을 위한 미앤더 선로와 개방형 루프가 결합된 방사구조의 설계 (Design of the Open-Loop Combined Meandered-Line 1-Layer Radiator for Diversity Antennas with Size-Reduction and Improved Isolation)

  • 목세균;강승택;김용진
    • 전기학회논문지
    • /
    • 제61권1호
    • /
    • pp.110-116
    • /
    • 2012
  • This paper proposes a new diversity antenna which is the base of MIMO, tunable and reconfigurable antennas. The antenna has a small size and high inter-antenna isolation resulting from the compact radiating element comprising a meandered line and an open-loop combined in one limited uniplanar space and a modified T-shaped decoupling structure, respectively. In a WiMAX band, the radiating element and the entire antenna are $0.092{\lambda}$ and $0.2216{\lambda}$ in size, which shows effective size-reduction and the gain and efficiency of the proposed antenna attached to the ground of a handheld device are 3.7dBi and 56% acceptable to the industrial standard.

초임계압형 화력발전소의 성능시험을 통한 최고효율점 선정에 관한 연구 (A Study on the Selection of Maxium Plant Efficiency through the Performance Test in Snper-Critical Power Plant)

  • 권여수;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.402-407
    • /
    • 2003
  • The main reason to select the maxium plant efficiency through the performance test in fossil power plant is to increase the efficiency of power plant as well as saving energy collated with the policy of government. This study is aimed at unerstanding the variantion trend of efficiency and analyzing the efficiency of boiler and turbine through each of the performance test. Ultimately, the maxium efficiency of power plant will be presented in super-critical pressure type power plant.

  • PDF

SAR규격을 만족하는 우수한 격리도의 소형 계단구조 광대역 MIMO 안테나 (Miniature Staircase-Shaped Wideband MIMO Antenna with Excellent Isolation, Compliant to the SAR Standard)

  • 강경석;양인규;강승택
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1413-1420
    • /
    • 2013
  • This paper proposes a novel compact MIMO antenna which has miniaturized radiators and their row correlation coefficient, working for the LTE mobile communication, and its SAR is observed. Each of the proposed radiators has a shape of staircase and the bandwidth is twice larger than the conventional PIFA as 600MHz(21%) in 2.5 GHz - 3.15 GHz. And the area of the radiators is $16.5mm{\times}9.7mm$ proper for a handheld device. Also, by adding a planar mushroom decoupling structure between the radiators, the isolation is improved. The design has been carried out using the commercial full-wave time-domain EM solver and the finalized MIMO antenna has the return loss less than -10 dB in the LTE band, the isolation better than 20 dB and the efficiency more than 90% with the gain of 4.3 dB. Regarding the SAR of the antenna, it is observed that the average SAR value of 1g is estimated as 1.37W/Kg, which is lower than the SAR standard.

Site-response effects on RC buildings isolated by triple concave friction pendulum bearings

  • Ates, Sevket;Yurdakul, Muhammet
    • Computers and Concrete
    • /
    • 제8권6호
    • /
    • pp.693-715
    • /
    • 2011
  • The main object of this study is to evaluate the seismic response effects on a reinforced concrete building isolated by triple concave friction pendulum (TCFP) bearings. The site-response effects arise from the difference in the local soil conditions at the support points of the buildings. The local soil conditions are, therefore, considered as soft, medium and firm; separately. The results on the responses of the isolated building are compared with those of the non-isolated. The building model used in the time history analysis, which is a two-dimensional and eight-storey reinforced concrete building with and without the seismic isolation bearings and/or the local soil conditions, is composed of two-dimensional moment resisting frames for superstructure and of plane elements featuring plane-stress for substructure. The TCFP bearings for isolating the building are modelled as of a series arrangement of the three single concave friction pendulum (SCFP) bearings. In order to investigate the efficiency of both the seismic isolation bearings and the site-response effects on the buildings, the time history analyses are elaborately conducted. It is noted that the site-response effects are important for the isolated building constructed on soft, medium or firm type local foundation soil. The results of the analysis demonstrate that the site-response has significant effects on the response values of the structure-seismic isolation-foundation soil system.

Rapid Isolation of Genomic DNA from Normal and Apoptotic Cells Using Magnetic Silica Resins

  • Park, Jee-Sun;Park, Jung-Hyun;Na, Shin-Young;Choe, Soo-Young;Choi, Sang-Nam;You, Kwan-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권5호
    • /
    • pp.890-894
    • /
    • 2001
  • The isolation of genomic DNA from mammalian cells is usually performed by cell lysis followed by protein digestion, extraction, and finally, ethanol precipitation of the chromosomal DNA. However, in the case of large sample numbers or when only small amounts of starting materials are available, such conventional methods are not efficient and are cumbersome to be applied. Some alternative methods have been described as well as having commercial DNA isolation kits to be available, nevertheless, there is room left for much improvement. In the present study, a novel method is introduced, where it simplifies conventional protocols by omitting some time-consuming steps such as protease incubation or DNA precipitation and its resuspension. Using paramagnetic silica resins, the genomic DNA was purified over a magnetic field, and the bound DNA was eluted with a low-salt buffer. The fidelity and effectiveness of this novel method was determined by using normal and apoptotic cells as a starting material and then compared to other protocols. The high speed and convenience along with its high efficiency in detecting apoptotic chromosomal DNA will prove this method to be an improved alternative in the isolation of genomic DNA from mammalian cells.

  • PDF

L.R.B.를 이용한 면진설계의 내지진 안전성 연구 (Study on Seismic Resistant Safety of Seismic Isolation Design for Bridge using L.R.B.)

  • 이철희;신재인
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.121-126
    • /
    • 2002
  • Due to few earthquakes in our country, one generally has thought to be safe from earthquakes. However, severe earthquakes occurred in Dangsan and Hyogohyeon which one had regarded as the zone that had not been risky for earthquakes, so that so many people died and a lot of buildings and bridges were destroyed. This event surprised our country and we undertook preparation for earthquakes on the full scale. The concept of seismic design was induced in the country which was poor in it for the scarcity of recognition and insufficiency of funds. Recently, many specialists are enforcing the provisions of seismic design. Therefore, this study introduces the method which combines PC-LEADeR( design program for L.R.B.) with LUSAS(linear elastic analysis) and performs the seismic isolation design more elaborately and simply. It verifies the propriety of that method, and it also examine the factors that affect the response of the bridges. Seismic isolation design for bridge using L.R.B. provides both economical efficiency and superior seismic performance. Second, the results between by the method proposed and by time history analysis have 20% error at the maximum. That is, the method proposed very appropriate.

Comparison of seismic behavior of long period SDOF systems mounted on friction isolators under near-field earthquakes

  • Loghman, Vahid;Khoshnoudian, Faramarz
    • Smart Structures and Systems
    • /
    • 제16권4호
    • /
    • pp.701-723
    • /
    • 2015
  • Friction isolators are one of the most important types of bearings used to mitigate damages of earthquakes. The adaptive behavior of these isolators allows them to achieve multiple levels of performances and predictable seismic behavior during different earthquake hazard levels. There are three main types of friction isolators. The first generation with one sliding surface is known as Friction Pendulum System (FPS) isolators. The double concave friction pendulum (DCFP) with two sliding surfaces is an advanced form of FPS, and the third one, with fully adaptive behavior, is named as triple concave friction pendulum (TCFP). The current study has been conducted to investigate and compare seismic responses of these three types of isolators. The structure is idealized as a two-dimensional single degree of freedom (SDOF) resting on isolators. The coupled differential equations of motion are derived and solved using state space formulation. Seismic responses of isolated structures using each one of these isolators are investigated under seven near fault earthquake motions. The peak values of bearing displacement and base shear are studied employing the variation of essential parameters such as superstructure period, effective isolation period and effective damping of isolator. The results demonstrate a more efficient seismic behavior of TCFP isolator comparing to the other types of isolators. This efficiency depends on the selected effective isolation period as well as effective isolation damping. The investigation shows that increasing the effective isolation period or decreasing the effective isolation damping improves the seismic behavior of TCFP compared to the other isolators. The maximum difference in seismic responses, the base shear and the bearing displacement, for the TCFP isolator are calculated 26.8 and 13.4 percent less than the DCFP and FPS in effective isolation damping equal to10%, respectively.

LRB와 슬라이딩베어링을 혼용한 면진시스템을 적용한 아파트 건물의 지진 응답 (Seismic Response of Apartment Building with Base Isolation System Consisting of Sliding-type Bearing and Lend Rubber Bearing)

  • 천영수;윤영호;황기태;장극관
    • 콘크리트학회논문집
    • /
    • 제19권4호
    • /
    • pp.507-514
    • /
    • 2007
  • 이 논문은 기존 내진설계와 비교하여 면진설계의 효용성과 경제적 효과에 대한 연구 결과를 정리한 것이며, 면진설계에 있어서는 납봉삽입적층고무베어링 (LRB)만을 사용한 경우와 비교하여 슬라이딩베어링과 LRB를 혼용한 면진시스템의 내진 거동을 함께 제시하였다. 연구 결과, 면진은 구조물에 대하여 지진동으로 인한 효과를 감소시키는데 매우 효과적이며, 층 가속도의 감소로 사용성을 증가시킬 수 있음이 입증되었다. 또한 층 가속도와 밑면 전단력의 감소라는 관점에서 슬라이딩베어링과 LRB를 혼용한 면진시스템이 LRB만을 사용한 경우보다 더 효과적임을 증명하였다. 하지만 경제적 효과 면에서는 증가된 성능에 비례하여 지불해야만 하는 비용도 커진다는 사실에 특별히 주의할 필요가 있는 것으로 나타났다.