• Title/Summary/Keyword: Isolation effect

Search Result 1,057, Processing Time 0.025 seconds

Seismic Fragility Evaluation of Isolated NPP Containment Structure Considering Soil-Structure Interaction Effect (지반-구조물 상호작용 효과를 고려한 지진격리시스템이 적용된 원전 격납건물의 지진 취약도 평가)

  • Eem, Seung Hyun;Jung, Hyung Jo;Kim, Min Kyu;Choi, In Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.53-59
    • /
    • 2013
  • Several researches have been studied to enhance the seismic performance of nuclear power plants (NPPs) by application of seismic isolation. If a seismic base isolation system is applied to NPPs, seismic performance of nuclear power plants should be reevaluated considering the soil-structure interaction effect. The seismic fragility analysis method has been used as a quantitative seismic safety evaluation method for the NPP structures and equipment. In this study, the seismic performance of an isolated NPP is evaluated by seismic fragility curves considering the soil-structure interaction effect. The designed seismic isolation is introduced to a containment building of Shin-Kori NPP which is KSNP (Korean Standard Nuclear Power Plant), to improve its seismic performance. The seismic analysis is performed considering the soil-structure interaction effect by using the linearized model of seismic isolation with SASSI (System for Analysis of Soil-Structure Interaction) program. Finally, the seismic fragility is evaluated based on soil-isolation-structure interaction analysis results.

Application of Mid-story Isolation System for Seismic Response Reducing of Dome Structure (돔 구조물의 지진응답 저감을 위한 중간 면진장치의 적용)

  • Kim, Gee-Cheol;Kim, Su-Geun;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.37-44
    • /
    • 2016
  • The seismic isolation system reduces the seismic vibration that is transmitted from foundation to upper structure. This seismic isolation system can be classified into base isolation and mid-story isolation by the installation location. In this study, the seismic behavior of dome structure with mid-story isolation is analyzed to verify the effect of seismic isolation. Mid-story isolation is more effective than base isolation to reduce the seismic responses of roof structure. Also, this isolation would be excellent in structural characteristics and construction.

Vibration mode decomposition response analysis of large floating roof tank isolation considering swing effect

  • Sun, Jiangang;Cui, Lifu;Li, Xiang;Wang, Zhen;Liu, Weibing;Lv, Yuan
    • Earthquakes and Structures
    • /
    • v.15 no.4
    • /
    • pp.411-417
    • /
    • 2018
  • To solve the seismic response problem of a vertical floating roof tank with base isolation, the floating roof is assumed to experience homogeneous rigid circular plate vibration, where the wave height of the vibration is linearly distributed along the radius, starting from the theory of fluid velocity potential; the potential function of the liquid movement and the corresponding theoretical expression of the base shear, overturning the moment, are then established. According to the equivalent principle of the shear and moment, a simplified mechanical model of a base isolation tank with a swinging effect is established, along with a motion equation of a vertical storage tank isolation system that considers the swinging effect based on the energy principle. At the same time, taking a 150,000 m 3 large-scale storage tank as an example, a numerical analysis of the dampening effect was conducted using a vibration mode decomposition response spectrum method, and a comparative analysis with a simplified mechanical model with no swinging effect was applied.

Foundation size effect on the efficiency of seismic base isolation using a layer of stone pebbles

  • Banovic, Ivan;Radnic, Jure;Grgic, Nikola
    • Earthquakes and Structures
    • /
    • v.19 no.2
    • /
    • pp.103-117
    • /
    • 2020
  • The effect of the foundation size on the efficiency of seismic base isolation using a layer of stone pebbles is experimentally investigated. Four scaled models of buildings with different stiffnesses (from very stiff to soft) were tested, each with the so-called small and large foundation, and exposed to four different accelerograms (different predominant periods and durations). Tests were conducted so that the strains in the model remained elastic and afterwards the models were tested until collapse. Each model was tested for the case of the foundation being supported on a rigid base and on an aseismic layer. Compared to the smaller foundation, the larger foundation results in a reduced rocking effect, higher earthquake forces and lower bearing capacity of the tested models, with respectable efficiency (reduced strain/stress, displacement and increase of the ultimate bearing capacity of the model) for the considered seismic base isolation compared to the foundation on a rigid base.

EM Coupling Effect of sprint inductors by isolation methode in standard CMOS process (Spiral 인덕터 간 격리방법에 따른 Electromagnetic 커플링 효과)

  • Choi, Moon-Ho;Kim, Han-Seok;Jung, Sung-Il;Kim, Yeong-Seuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.91-92
    • /
    • 2005
  • The electromagnetic coupling effect in standard CMOS process is simulated and evaluated. EM coupling transfer characteristic between planar spiral inductors by isolation methode in standard CMOS have simulated and measured. Measurement results show that suppression of EM coupling effect by ground guardring. The evaluated structures are fabricated 1P5M(one poly, five metal) 0.25um standard CMOS process. These measurement results provide a isolation design guidelines in standard CMOS process for Rf coupling suppression.

  • PDF

Optimal In-Plane Configuration of 3-axis MEMS IMUs Considering Fault Detection and Isolation Performance and Lever Arm Effect (레버암 효과와 고장 감지 및 배제 성능을 고려한 여분의 3축 MEMS IMU의 평면 배치 기법)

  • Kim, Eung Ju;Kim, Yong Hun;Choi, Min Jun;Song, Jin Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1648-1656
    • /
    • 2018
  • The configuration of redundant inertial sensors are very important when considering navigation performance and fault detection and isolation (FDI) performance. By constructing a redundant sensor system using multiple inertial sensors, it is possible to improve the navigation performance and fault detection and isolation performance, which are highly related to the sensor configuration and allocation. In order to deploy multiple MEMS inertial measurement units effectively, a configuration and allocation methods considering navigation performance, fault detection and isolation performance, and lever arm effect in one plane are presented, and the performance is analyzed through simulation in this research. From the results, it is confirmed that the proposed configuration and allocation method can improve navigation, FDI, and lever arm effect rejection performances more effectively by more than 70%.

The Effect of Social Isolation on Dementia in rural elderly: Comparison Between Young-old and Old-old Group (농촌 노인의 사회적 고립이 치매에 미치는 영향 : 전기노인과 후기노인 비교 분석)

  • Lee, Sangchul
    • Korean Journal of Social Welfare Studies
    • /
    • v.48 no.2
    • /
    • pp.143-171
    • /
    • 2017
  • Along with the well-established evidence on the negative effect of social isolation on physical mental health and mortality, increasing attention has been paid to multi-dimensional nature of social isolation. In this study, the main effect and interaction effect of objective and subjective social isolation on heterogeneous age cohort related to the onset of dementia, which is becoming a social problem due to rapid aging of health issues, was examined through binary logistic regression analysis. Data came from the first wave of Korean Social Life, Health and Aging Project (KSHAP) (N= 814). Findings showed 1) in the young-old, objective isolation was a significant on the incidence of dementia, 2) in the old-old, subjective isolation increased the risk of dementia. In summary, the relative influence of objective and subjective social isolation related to the incidence of dementia varies depending on the young-old and old-old. On the other hand, the interaction effect of objective and subjective social isolation on dementia was not significant in both the young-old and old-old. Based on the findings, we discussed implications and suggestions for future research and relevant policy and program development(dementia-friendly communities) for ameliorating objective and subjective social isolation.

Conceptual Application Schemes of Seismic Isolation Techniques to Hanok (한옥의 면진기법 적용 방안에 대한 개념적 고찰)

  • Park, Bum-Soo;Kim, Yeong-Min;Hur, Moo-Won;Lee, Sang-Hyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.1
    • /
    • pp.137-146
    • /
    • 2020
  • In this study, various application schemes of seismic isolation system which can be applied to Hanok have been studied by analyzing its structural characteristics under seismic load. Structural stability of Hanok is more required against seismic load as Hanok becomes long-spanned and multi-storied. To meet this goal, it becomes necessary to study more advanced technology such as seismic isolation design as well as seismic control design and seismic resistant design suitable to Hanok. Seismic isolation systems have been successfully applied to RC and steel structures to improve structural performance during earthquakes. Based on these previous study, we proposed four application schemes of seismic isolation design suitable for Hanok and analyzed their structural characteristics and applicability to Hanok in conceptual level based on its structural characteristics. The proposed four schemes are base isolation method, ground isolation method, roof isolation method and intermediate-story isolation method. The applicability of the proposed method was evaluated by performing boundary nonlinear dynamic analysis to the typical Hanok for the two types of isolation method, that is, ground isolation method and roof isolation method, and the results showed that the proposed methods produced good performance enough to be applied to Hanok.

Isolation Effectiveness by Progressive Space Organization in Negative Pressured Isolation Unit (음압격리병실에 있어서 단계별 공간구성의 격리효과)

  • Kwon, Soonjung;Sung, Minki
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.79-86
    • /
    • 2016
  • Purpose: The purpose of this study is to identify the effect of Progressive Space Organization (ante-rooms) in Negative Pressured Isolation Unit(NPIU) such as National and Regional Isolation Units in Korea in order to build basic data for the evidence based design of Airborne Infection Isolation Units which should prepare and respond effectively to the public health crisis due to the hazardous airborne infectious disease. Methods: 1) Gas(SF6) test and analysis on the 23 Korean Isolation Units under operation. 2) Assessment of the isolation level of the space components by checking the Gas concentration. 3) Analysis of the Isolation Effectiveness according to Space Organizational levels. Results: 1) The higher segregation level is, the lower Gas(SF6) concentration is. 2) Too many segregations(anterooms) of Isolation Unit are not efficient for the prevention of infectious bacillus spread. For example, 4 level of segregation has similar segregation effect to the 3 level of segregation. Implications: Many anterooms in front of the isolated patient bedroom will guarantee the safe environment against the danger of hazardous airborne nosocomial infection. On the other hand, too many segregations is inefficient, expensive, inconvenient, narrow(unflexible) and so on. This study can be used as basic data for further development of design guidelines of isolation units.

The Effect of Sputter-textured Mo Thin Film on Magnetic properties of CoCrTa/Cr Magnetic Recording Media (Sputter-textured Mo 박막이 CoCrTa/Cr 자기기록매체의 자기적 성질에 미치는 영향)

  • Jo, Sung-Mook;Nam, In-Tak
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.221-229
    • /
    • 2001
  • The effect of Mo underlayer on the magnetic properties of CoCrTa/Cr films deposited on glass substrates were investigated. The coercivity increased and the coercivity squareness decreased by introducing Mo underlayer. The coercivity increase was attributed to the increase of in-plane c-axis orientation and magnetic isolation of Co grains deposited on Cr/Mo underlayer. The decrease of coercivity squarenesses seemed to be caused by the increase of magnetic isolation. The increase of magnetic isolation of Co grains was attributed to the diffusion of Mo atoms into grain boundaries of Co films and the physical isolation of Co grains. The coercivity of CoCrTa/Cr/Mo showed maximum values at Mo thickness of $400{\AA}$. The appearance of the maximum coercivity at that thickness was attributed to the development of strong $Co(10{\bar{1}}0)$ and $Co(10{\bar{1}}1)$ preferred orientation.

  • PDF