• 제목/요약/키워드: Isolation Test

검색결과 970건 처리시간 0.029초

E-Isolation : High-performance Dynamic Testing Installation for Seismic Isolation Bearings and Damping Devices

  • Yoshikazu Takahashi;Toru Takeuchi;Shoichi Kishiki;Yozo Shinozaki;Masako Yoneda;Koichi Kajiwara;Akira Wada
    • 국제초고층학회논문집
    • /
    • 제12권1호
    • /
    • pp.93-105
    • /
    • 2023
  • Seismic isolation and vibration control techniques have been developed and put into practical use by challenging researchers and engineers worldwide since the latter half of the 20th century, and after more than 40 years, they are now used in thousands of buildings, private residences, highways in many seismic areas in the world. Seismic isolation and vibration control structures can keep the structures undamaged even in a major earthquake and realize continuous occupancy. This performance has come to be recognized not only by engineers but also by ordinary people, becoming indispensable for the formation of a resilient society. However, the dynamic characteristics of seismically isolated bearings, the key elements, are highly dependent on the size effect and rate-of-loading, especially under extreme loading conditions. Therefore, confirming the actual properties and performance of these bearings with full-scale specimens under prescribed dynamic loading protocols is essential. The number of testing facilities with such capacity is still limited and even though the existing labs in the US, China, Taiwan, Italy, etc. are conducting these tests, their dynamic loading test setups are subjected to friction generated by the large vertical loads and inertial force of the heavy table which affect the accuracy of measured forces. To solve this problem, the authors have proposed a direct reaction force measuring system that can eliminate the effects of friction and inertia forces, and a seismic isolation testing facility with the proposed system (E-isolation) will be completed on March 2023 in Japan. This test facility is designed to conduct not only dynamic loading tests of seismic isolation bearings and dampers but also to perform hybrid simulations of seismically isolated structures. In this paper, design details and the realization of this system into an actual dynamic testing facility are presented and the outcomes are discussed.

Seismic performance and design of bridge piers with rocking isolation

  • Chen, Xingchong;Xia, Xiushen;Zhang, Xiyin;Gao, Jianqiang
    • Structural Engineering and Mechanics
    • /
    • 제73권4호
    • /
    • pp.447-454
    • /
    • 2020
  • Seismic isolation technology has a wide application to protect bridges from earthquake damage, a new designed bridge pier with seismic isolation are provided for railways in seismic regions of China. The pier with rocking isolation is a self-centering system under small and moderate earthquakes, and the unbonded prestressed tendons are used to prevent overturning under strong earthquakes. A numerical model based on pseudo-static testing results is presented to evaluate the seismic performance of isolation bridge piers, and is validated by the shaking table test. It is found that the rocking response and the loss of prestressing for the bridge pier increase with the increase of earthquake intensity. Besides, the intensity and spectral characteristics of input ground motion have great influence on displacement of the top and bottom of the bridge pier, while have less influence on the bending moment of the pier bottom. Experimental and numerical results show that the rocking-isolated piers presented in this study have good seismic performance, and it provides an alternative way for the railway bridge in the regions with high occurrence of earthquakes. Therefore, we provide the detailed procedures for seismic design of the rocking-isolated bridge pier, and a case study of the seismic isolation design with rocking piers is carried out to popularize the seismic isolation methods.

추백리 혈청검사 양성 산란계로부터 Salmonella속균 분리 (Isolation of Salmonella from the layer chickens reacting in pullorum-typhoid agglutination test)

  • 류재윤;전무형;장경수;손현수;곽학구;박경재;우용구
    • 한국동물위생학회지
    • /
    • 제22권3호
    • /
    • pp.221-237
    • /
    • 1999
  • To investigate the specificity of rapid slide agglutination test for pullorum-gallinarum diseases and to obtain a basic data for avian salmonellosis control, salmonella isolation was peformed for the layer chickens positively reacted in pullonlm-typhoid agglutination test. The biochemical, serological and antimicrobial properties of the isolates were examined. The results obtained through this study were summarized as follows; 1. Of 2,384 chickens tested by the agglutination test, 606 chickens (25.4%) were positive reactors. 154 of 606 reactors and 49 of the non-reacting chickens were investigated for salmonella isolation, resulting in isolation of 68 strains of salmonellae from 27 chickens. 2. By organs, the isolation frequency from liver, cecum, spleen, ovary and gall bladder showed 8.9% (18 strains), 8.9% (18 strains), 7.4% (15 strains), 4.4% (9 strains) and 3.9% (8 strains), respectively. 3. By culture medium the combination of selenite broth and MacConkey agar revealed the highest isolation rate and the enrichment culture by delayed secondary enrichment culture method was found the most effective for salmonella isolation. 4. The serotypes of 68 salmonella isolates were identified as 3 strains of S pullorum, 24 strains of S gallinarum, 15 strains of S typhimurium, 8 strains of S enteritidis, 7 strains of S paratyphi A, 5 strains of S typhimurium and 6 strains of the other salmonellae. 5. The serotypes of 8 salmonella strains isolated from 49 chickens non-reacting in pullorum-typhoid agglutination test were identified as 3 strains of S typhimurium and 5 strains of S infantis. 6. When 24 chickens of which 68 strains of salmonellae isolated were examined by microplate agglutination test, the average antibody titer for pullorum antigen was $2^{5.25}$. The chickens at antibody titer between $2^3$ and $2^5$ showed the higher frequency of isolation as compared with the chickens at the other titers. 7. When salmonella isolates were tested the antimicrobial drug sensitivity by disk diffusion method, S paratyphi A were highly sensitive by 100% to ATM and GM, S typhimurium, by 88% to AM, CIP, IMP and TN, S infantis, by 100% to AM, CRO, ENR and PIP, S enteritidis,by 100% to IMP and PIP, S pullorum, by 100% to ATM, CRO, ENR and PIP and S gallinarum, by 92% to CRO, CIP and PIP.

  • PDF

Experiment of an ABS-type control strategy for semi-active friction isolation systems

  • Lu, Lyan-Ywan;Lin, Ging-Long;Lin, Chen-Yu
    • Smart Structures and Systems
    • /
    • 제8권5호
    • /
    • pp.501-524
    • /
    • 2011
  • Recent studies have discovered that a conventional passive isolation system may suffer from an excessive isolator displacement when subjected to a near-fault earthquake that usually has a long-period velocity pulse waveform. Semi-active isolation using variable friction dampers (VFD), which requires a suitable control law, may provide a solution to this problem. To control the VFD in a semi-active isolation system more efficiently, this paper investigates experimentally the possible use of a control law whose control logic is similar to that of the anti-lock braking systems (ABS) widely used in the automobile industry. This ABS-type controller has the advantages of being simple and easily implemented, because it only requires the measurement of the isolation-layer velocity and does not require system modeling for gain design. Most importantly, it does not interfere with the isolation period, which usually decides the isolation efficiency. In order to verify its feasibility and effectiveness, the ABS-type controller was implemented on a variable-friction isolation system whose slip force is regulated by an embedded piezoelectric actuator, and a seismic simulation test was conducted for this isolation system. The experimental results demonstrate that, as compared to a passive isolation system with various levels of added damping, the semi-active isolation system using the ABS-type controller has the better overall performance when both the far-field and the near-fault earthquakes with different PGA levels are considered.

Effect of the limiting-device type on the dynamic responses of sliding isolation in a CRLSS

  • Cheng, Xuansheng;Jing, Wei;Li, Xinlei;Lu, Changde
    • Earthquakes and Structures
    • /
    • 제15권2호
    • /
    • pp.133-144
    • /
    • 2018
  • To study the effectiveness of sliding isolation in a CRLSS (concrete rectangular liquid-storage structure) and develop a reasonable limiting-device method, dynamic responses of non-isolation, sliding isolation with spring limiting-devices and sliding isolation with steel bar limiting-devices are comparatively studied by shaking table test. The seismic response reduction advantage of sliding isolation for concrete liquid-storage structures is discussed, and the effect of the limiting-device type on system dynamic responses is analyzed. The results show that the dynamic responses of sliding isolation CRLSS with steel bar-limiting devices are significantly smaller than that of sliding isolation CRLSS with spring-limiting devices. The structure acceleration and liquid sloshing wave height are greatly influenced by spring-limiting devices. The acceleration of the structure in this case is close to or greater than that of a non-isolated structure. Liquid sloshing shows stronger nonlinear characteristics. On the other hand, sliding isolation with steel bar-limiting devices has a good control effect on the structural dynamic response and the liquid sloshing height simultaneously. Thus, a limiting device is an important factor affecting the seismic response reduction effect of sliding isolation. To take full advantage of sliding isolation in a concrete liquid-storage structure, a reasonable design of the limiting device is particularly important.

음압격리병실에 있어서 단계별 공간구성의 격리효과 (Isolation Effectiveness by Progressive Space Organization in Negative Pressured Isolation Unit)

  • 권순정;성민기
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권4호
    • /
    • pp.79-86
    • /
    • 2016
  • Purpose: The purpose of this study is to identify the effect of Progressive Space Organization (ante-rooms) in Negative Pressured Isolation Unit(NPIU) such as National and Regional Isolation Units in Korea in order to build basic data for the evidence based design of Airborne Infection Isolation Units which should prepare and respond effectively to the public health crisis due to the hazardous airborne infectious disease. Methods: 1) Gas(SF6) test and analysis on the 23 Korean Isolation Units under operation. 2) Assessment of the isolation level of the space components by checking the Gas concentration. 3) Analysis of the Isolation Effectiveness according to Space Organizational levels. Results: 1) The higher segregation level is, the lower Gas(SF6) concentration is. 2) Too many segregations(anterooms) of Isolation Unit are not efficient for the prevention of infectious bacillus spread. For example, 4 level of segregation has similar segregation effect to the 3 level of segregation. Implications: Many anterooms in front of the isolated patient bedroom will guarantee the safe environment against the danger of hazardous airborne nosocomial infection. On the other hand, too many segregations is inefficient, expensive, inconvenient, narrow(unflexible) and so on. This study can be used as basic data for further development of design guidelines of isolation units.

고감쇠면진고무베어링의 유한요소해석 (Finite Element Analysis of High Damping Rubber Bearing for Seismic Isolation)

  • 전정배;김홍주;정경수;김계수;강범수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.292-297
    • /
    • 2000
  • The seismic isolation technology has appeared to be increasingly necessary for highway bridges, LNG tank, nuclear power plant, and building structures in view of earthquake vibrations. Also high-technology industries require effective seismic protection. The Seismic Isolation Bearing - High Damping Rubber Bearing - system has been counted as the most effective way fur seismic isolation, which is now under development and widely used in industries. Here, the commercial FEM software for nonlinear analysis, MARC, has provided force-displacement curves on the rubber system. The analyses have been carried out about fourteen cases; 25%, 50%, 75%, 100%, 125% and 150% horizontal displacements with a different frequency - 0.01Hz and 0.50Hz - and 100% horizontal displacement with four different frequency - 0.01Hz, 0.16667Hz, 0.3333Hz and 0.50Hz. The unknown constants of the strain energy function of Ogden model have been obtained by a tension test and planar shear test.

  • PDF

일반공산비 기법을 이용한 SDINS/GPS 통합시스템의 고장 검출 및 격리 (Fault Detection and Isolation of Integrated SDINS/GPS System Using the Generalized Likelihood Ratio)

  • 신정훈;임유철;유준
    • 한국군사과학기술학회지
    • /
    • 제3권2호
    • /
    • pp.140-148
    • /
    • 2000
  • This paper presents a fault detection and isolation(FDI) method based on Generalized Likelihood Ratio(GLR) test for the tightly coupled SDINS/CPS system. The GLR test is known to have the capability of detecting an assumed change while estimating its occurrence time and magnitude, and isolating the changing part. Once a fault is detected even if we don't know if the fault occurrs at either INS or GPS, multi-hypothesized GLR scheme performs the fault isolation between INS and GPS, and find which satellite malfunctions. However, in the INS faulty case, it turned out to fail to accomodate the fault isolation between accelerometer and gyroscope due to the coupling effects and a poor observability of the system. Hence, to isolate the INS fault, it needs to change the attitude of the vehicle resulting in enhancing the degree of observability.

  • PDF

일반공산비 기법을 이용한 INS/GPS 통합시스템의 고장 검출 및 격리 (Fault Detection and Isolation of Integrated Inertial/Satellite Navigation Systems Using the Generalized Likelihood Ratio Test)

  • 신정훈;임유철;유준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.55-55
    • /
    • 2000
  • This paper presents a fault detection and isolation(FDI) method based on Ceneralized Likelihood Ratio(GLR) test for the tightly coupled INS/GPS. State and measurement GLR tests detect INS or GPS fault. Once the fault is detected, Multi-hypothesized GLR scheme performs the fault isolation between INS and GPS and find which satellite malfunctions. Simulation results show that the GLR method is effective enough to detect and isolate a fault of the integrated navigation system.

  • PDF

함정용 전술 컴퓨터 콘솔의 방진 (Isolation Mount Design for the Combat Computer Console Installed in Surface Ship)

  • 권병현;김준;김진천;서송호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1772-1777
    • /
    • 2000
  • The Combat Computer Consoles installed in surface ships should endure harsh environment such as vibration from engine or propeller and shock from underwater explosion. Generally, commercial isolation mounts are selected and used for anti-vibration and anti-shock design. In this research, the environment of the Combat Computer Console was analyzed first. Selected proper mount was modeled and computer simulation was performed to emulate the environment test. The real environment test was conducted with a manufactured Combat Computer Console. The test results were same as the simulation and satisfied the performance requirements. The computer simulation proved to be a useful design tool to predict the performance before the final environment test.

  • PDF