We have developed a ground-isolation circuit in order to reduce the noise of the internal controller system for the total artificial heart(TAH) and ventricular assist device(VAD). Using the ground-isolation technique, we could transmit the analog target signal to other pheriperal device including IBM PC via RS232C and polygraph, with no noise. Experimental results of VAD showed that there was less impulsive noise in current signal which caused in our previous conventional system. Therefore it could be proved that implementation of isolation technique is very effective to improve the signal to noise ratios of analog signal transmission for TAH or VAD.
The Transformation-Associated Recombination (TAR) cloning technique allows selective isolation of chromosomal regions and genes from complex genomes. The procedure requires knowledge of relatively small genomic sequences that reside adjacent to the chromosomal region of interest. This technique involves homologous recombination during yeast spheroplast transformation between genomic DNA and a TAR vector that has 5'and 3' gene targeting sequences. In this study, we examined the minimum size of specific hooks required for a single-copy gene isolation and compared the utility of different TAR vectors, radial and unique vectors, by cloning the same single-copy gene. The efficiency of TAR cloning of the hHPRT gene was same using hooks varying from 750 to 63 bp. The number of transformants decreased approximately 20-fold when the TAR vector contained two unique hooks versus using a radial vector, but the percentage of positive recombinants increased over 2-fold when a unique TAR vector was used. Therefore, we suggest that the two-unique TAR vector is suitable for general TAR cloning given its high selectivity, and the radial TAR vector is more suitable when genomic DNA is in limited quantity, for example, DNA isolated from pathological specimens. Moreover, we confirm the minimal length of a unique sequence in a TAR vector is approximately 60 bp for a single-copy gene isolation.
Transactions of the Korean Society of Mechanical Engineers A
/
v.20
no.2
/
pp.500-510
/
1996
This paper presents a new prototype of an engine mount for a passenger vehicle featuring ER(elector-rheological) fluids and piezoactuators. Conventional rubber mounts and various types of passive or semi-active hydraulic engine mounts have their own functional aims on the limited frequency band in the board engine operating frequency range. However, the proposed engine mount covers all frequency range of the engine operation. A mathematical model of the proposed engine mount is derived using the bond graph method which is inherently domain, the ER fluid is activated upon imposing electric field for vibration isolation while the piezoactuator. Computer control electric fluid for the ER fluid H.inf. cotrol technique is adopted for the piezoactuator. Computer simulation is undertaken in order to demonstrate isolation efficiency of the engine mount over wide operating frequency range.
The minor components of $saponin-ginsenoside-Rf,\;-Rg_2\;and\;-Rh_1$ were isolated from Panax ginseng C.A. Meyer by preparative, semi-preparative and analtical high performance liquid chromatography. The rapid method developed in this work was proved to be very effective in separation and isolation of these minor ginsenosides. A further isolation was achieved by using the recycling technique.
Multicopters have become more popular since they are advantageous in their ability to take off and land vertically. In order to guarantee the normal operations of such multicopters, the problem of fault detection and isolation is very important. In this paper, a new method for detecting and isolating an actuator fault of a hexacopter is proposed based on the analytical approach. The residual is newly defined using the angular velocities of actuators estimated by the mathematical model and an actuator fault is detected comparing the residuals to a threshold. And a fault is isolated combining a dynamic model and generated residuals when a fault is detected. The proposed method is a simple, but effective technique because it is based on mathematical model. The results of the computer simulation are also given to demonstrate the validity of the proposed algorithm in case of a single failure.
Casciati, F.;Casciati, S.;Colnaghi, A.;Faravelli, L.;Rosadini, L.;Zhu, S.
Smart Structures and Systems
/
v.24
no.5
/
pp.641-648
/
2019
The authors investigate the feasibility of applying a vision-based displacement-measurement technique in the characterization of a SMA damper recently introduced in the literature. The experimental campaign tests a steel frame on a uni-axial shaking table driven by sinusoidal signals in the frequency range from 1Hz to 5Hz. Three different cameras are used to collect the images, namely an industrial camera and two commercial smartphones. The achieved results are compared. The camera showing the better performance is then used to test the same frame after its base isolation. U-shaped, shape-memory-alloy (SMA) elements are installed as dampers at the isolation level. The accelerations of the shaking table and those of the frame basement are measured by accelerometers. A system of markers is glued on these system components, as well as along the U-shaped elements serving as dampers. The different phases of the test are discussed, in the attempt to obtain as much possible information on the behavior of the SMA elements. Several tests were carried out until the thinner U-shaped element went to failure.
Base isolation is one of the most widely implemented and well-known technique to reduce structural vibration and damages during an earthquake. However, while the base-isolated structure reduces storey drift significantly, it also increases the base drifts causing many practical problems. This study proposes the use of Shape Memory Alloys (SMA) wires for the reduction in base drift while controlling the overall structure vibrations. A multi-degree-of-freedom (MDOF) structure along with base isolators and Shape-Memory-Alloys (SMA) wires in diagonal is tested experimentally and analytically. The isolation bearing considered in this study consists of laminates of steel and silicon rubber. The performance of the proposed structure is evaluated and studied under different loadings including harmonic loading and seismic excitation. To assess the seismic performance of the proposed structure, shake table tests are conducted on base-isolated MDOF frame structure incorporating SMA wires, which is subjected to incremental harmonic and historic seismic loadings. Root mean square acceleration, displacement and drift are analyzed and discussed in detail for each story. To better understand the structure response, the percentage reduction of displacement is also determined for each story. The result shows that the reduction in the response of the proposed structure is much better than conventional base-isolated structure.
Journal of the korean academy of Pediatric Dentistry
/
v.30
no.3
/
pp.415-422
/
2003
Currently, 'National program of dental sealant' has begun in Korea, but various isolation techniques and preparation is performing. The aim of the present study was to compare pit and fissure sealant retention rates between different operators using two different isolation techniques. Additionally, the failed surface was examined. One examiner performed the examination after one year of the initial operation. The population consisted of 119 children(mean age $8.59{\pm}0.772$) of which the total sealed number was 279 permanent first molars. Pediatric dentists sealed 131 molars using the rubber dam isolation technique (Group 1), general practitioners sealed 80 molars using the rubber dam isolation technique (Group 2), and dental hygienists sealed 69 molars using the cotton roll isolation (Group 3). The results were as follows ; 1. The complete retention rate between Group 1 (90.8%) and 2 (85.0%) showed no significant statistical difference (P>0.05). However, there were significant statistical different retention rates between Group 1 and Group 3(64.7%) and between Group 2 and Group 3 (p<0.05). 2. In comparing retention rates between maxilla and mandible, Only Group 3 showed a significantly lower complete retention rate in mandible than maxilla (p<0.05). 3. In failed surface analysis, occlusal failed surface was 58.3%, buccal/palatal failed surface was 41.7%.
Cultural method, dark field microscopy & fluorescent antibody technique were compared for their sensitivity of the detection of leptospires from experimentally infected mice. Two groups of mice were infected with L. icterohemorrhagiae (M20) and L. australis (Ballico), and the infected blood, urine and a number of organs were subjected to the bacterial isolation. The results obtained were summarized as follows: 1. L. icterohemorrhagiae (M20) and L. australis (Ballico) in blood, urine and various tissues of experimentally infected mice were detected with a negrigible non specificity, by the fluorescent antibody technique. 2. The fluorescent antibody technique, as applied to detection of leptospires in blood, urine and various infected tissue, proved to be better than cultural method and dark-field microscopy. 3. Early detection of leptospires by fluorescent antibody technique were possible in blood at 2 days after inoculation, whereas detection of organisms in liver, spleen, lung and kidney were observed later. By means of fluorescent antibody technique, the detection of leptospires in kidney and urine was possible up to 34 days postinoculation, whereas those in other parts were impossible. 4. Fluorescent antibody reaction of leptospires were highly specific to homologous antigen rather than to heterologous one. 5. Fluorescent antibody technique may be of value in the application for the demonstration of leptospira from clinical specimens.
In this paper, auto-tuning technique of the PID controller gain by particle swarm optimization algorithm is presented. PID controller is easy to implement to numerous control systems. After PID gain tuning is completed, its result could be implemented to control spacecraft vibration such as jitter that is high frequency vibration usually over 10Hz. The off-line PID controller tuning is done under system nonlinearities and uncertainties existence, then its result is applied to control experiment device to prove the PSO efficiencies.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.