• 제목/요약/키워드: Isolation Level

검색결과 798건 처리시간 0.039초

전달함수법을 이용한 장비가진력과 바닥진동응답의 예측 (Prediction of the Exciting Force of Machine and the Vibration Response of Floor Using Transfer Function Method)

  • 김석홍;김준호;이홍기
    • 소음진동
    • /
    • 제2권4호
    • /
    • pp.273-280
    • /
    • 1992
  • The prediction of vibration response of floor is necessary in order to check whether the floor vibration level will satisfy the allowable vibration standard of precise machinery such as electronic microscopes in semiconductor manufacturing plant before the installation of various neighboring equipment facility. In conventional vibration isolation, we were mainly interested in minimization of vibration transmissibility and stabilization of vibration isolation system. But in order to predict vibration response of floor, it is necessary to know exciting force of equipment installed on the floor and the mobility of the floor. We measured the exciting force of the dropped mass assumed as equipment and the mobility of some practical building floor using large impact hammer. And from this we predicted the vibration response of floor on which the mass dropped. This predicted vibration response of floor is compared with measured vibration response. Through upper procedure, we examined the possibility of predicting vibration response of floor from the information of exciting force of equipment and the mobility of floor.

  • PDF

고무마운트를 통한 장비의 고체음 전달에 관한 연구 (Study on the Structure-borne Sound Transmission of a Machine through Rubber Mounts)

  • 김봉기;김재승;김현실;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.655-660
    • /
    • 2000
  • Machines on board a ship are mounted on decks and transmit its structure-borne sound to the deck through resilient mounts. To predict the ship noise generated by the structure-borne sound of the machine, It is necessary to estimate the vibration level of the base structure. In this paper, a simple dynamic model is considered for vibration isolation systems consisting of a source, an isolator, and a base structure. The high frequency mobilities of the simple base structure are reviewed and wave effects in the mount are discussed in relation to isolation performance.

  • PDF

FPS로 면진된 원전 주제어실의 내진 성능 평가 (Seismic Performance Evaluation for MCR of Nuclear Power Plant Isolated by FPS)

  • 김대곤;김우범;서용표;문대식;김종엽
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.453-460
    • /
    • 2003
  • The objective of this study is to investigate the seismic performance for a seismically isolated main control room (MCR) of nuclear power plant. MCR was isolated by spherically shaped friction pendulum system (FPS). The FPS provided the simplest means of achieving long period in the isolation system under low gravity load. Some parametric studies were conducted with different properties of FPS. When the coefficient of friction in the sliding surface of FPS is low, the seismic performance of MCR was satisfactory However, the lateral displacement in the isolation level was rather large. To restrict this displacement into adequate range, a fluid viscous dampers were used.

  • PDF

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Kumar, Pardeep;Petwal, Sandeep
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.401-413
    • /
    • 2019
  • The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.

전차단 상태에서 동작하는 안테나 튜닝스위치의 RF 보호기술 (RF protection technique of antenna tuning switch in all-off condition)

  • Jhon, Heesauk;Lee, Sanghun
    • 한국정보통신학회논문지
    • /
    • 제26권10호
    • /
    • pp.1567-1570
    • /
    • 2022
  • This paper, we presents a RF protection technique of antenna switch by improving the power handling capability in worst case environment mode for mobile phone applications without critical payment of circuit performances such as insertion loss, isolation and ACBV (AC breakdown voltage). By applying a additional capacitive path located in front of the antenna in cell-phone, it performs the effective reduction of input power in high voltage standing wave ratio (VSWR) condition. Under the all-path off condition which causes a high VSWR, it achieved 37.7dBm power handling level as high as 5.7dB compared to that of conventional one at 2GHz. In addition, insertion loss and isolation performances were 0.31dB and 42.72dB at 2 GHz, respectively which were almost similar to that of the conventional circuit. The proposed antenna switch was fabricated in 130nm CMOS SOI technology.

Co-located and space-shared multiple-input multiple-output antenna module and its applications in 12 × 12 multiple-input multiple-output systems

  • Longyue Qu;Haiyan Piao;Guohui Dong
    • ETRI Journal
    • /
    • 제45권2호
    • /
    • pp.203-212
    • /
    • 2023
  • In this study, we developed a co-located and space-shared multiple-input multiple-output (MIMO) antenna module with a modular design and high integration level. The proposed antenna pair includes a half-wavelength loop antenna and a dipole-type antenna printed on the front and back sides of a compact modular board. Owing to their modal orthogonality, these two independent antenna elements are highly self-isolated and free of additional decoupling components, even though they are assembled at the same location and within the same space. Thus, the proposed antenna is attractive in 5G MIMO systems. Furthermore, the proposed co-located and space-shared MIMO antenna module was employed in a 5G smartphone to verify their radiation and diversity performances. A 12 × 12 MIMO antenna system was simulated and fabricated using the proposed module. Based on the results, the proposed module can be employed in large-scale MIMO antenna systems for current and future terminal devices owing to its high integration, compactness, simple implementation, and inherent isolation.

Vancomycin 내성 장구균 집락 해제에 대한 보중익기탕의 효과 (The Effects of Bojungiki-tang by Withdraw of Isolation of Vancomycin-resistant enterococci Colonization - Case Series)

  • 윤승규;박주영;변형식;권승원;서유리;정우상;문상관;조기호;김영석
    • 대한한방내과학회지
    • /
    • 제31권4호
    • /
    • pp.908-913
    • /
    • 2010
  • Bojungiki-tang is a traditional oriental medicine to boost the immune system. In this study, we investigated the effects of Bojungiki-tang by withdrawal of isolation of VRE colonization. Four cases of post-stroke patients with VRE colonization took Bojungiki-tang and continuously were followed up with stool cultures. After three times negative stool VRE, we withdrew isolation of VRE colonization. One case patient was diagnosed with VRE colonization in another hospital and had no withdrawal during that period. He was admitted to Kyung-hee University Oriental Medicine where he took Bojungiki-tang. After three times negative stool VRE, we withdrew isolation of the patient. These results demonstrate that Bojungiki-tang is effective on boosting immunity level. Further studies are needed to better characterize this protective effect of Bojungiki-tang.

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

Modified sorbitol MacConkey agar for the rapid isolation of Escherichia coli O157:H7

  • Jung, Byeong-yeal;Jung, Suk-chan;Lee, Na-kyung;Cho, Seong-kun;Cho, Dong-hee;Her, Moon;Yoon, Yong-dhuk;Kim, Bong-hwan
    • 대한수의학회지
    • /
    • 제39권4호
    • /
    • pp.765-771
    • /
    • 1999
  • Unlike most Escherichia coli strains, E coli O157 : H7 didn't ferment sorbitol within 24h of incubation and showed a negative reaction for $\beta$-glucuronidase. We developed a new medium for the rapid isolation of E coli O157 : H7 using sorbitol MacConkey agar with cefixime, potassium tellurite and 4-methylumbelliferyl-${\beta}$-D-glucuronide (MUG) as a primary plating medium. The addition of $20{\mu}g/ml$ of vancomycin in enrichment broth for E coli O157 : H7 inhibited lots of Gram positive bacteria. Three strains (10.3%) of 29 non-O157 E coli strains and 3 strains (8.3%) of 36 Salmonella spp were inhibited at the $0.05{\mu}g/ml$ of cefixime and 23 strains (79.3%) of 29 non-O157 E coli strains and 12 strains (33.3%) of 36 Salmonella spp were inhibited at the $2.0{\mu}g/ml$ of potassium tellurite. But none of the E coli O157 : H7 was affected at these concentration. The addition of MUG at $100{\mu}g/ml$ level to sorbitol MacConkey agar with cefixime and potassium tellurite (CTM-SMAC) aided in the rapid isolation of E coli O157 : H7 from samples by checking sorbitol-negative and $\beta$-glucuronidase negative phenotypes simultaneously. In conclusion, inoculation of a positive in the O157 screening test from enrichment broth on CTM-SMAC appeared to be a rapid, cost-effective and sensitive method for the isolation of E coli O157 : H7.

  • PDF

Isolation Frequency Characteristics of Candida Species from Clinical Specimens

  • Kim, Ga-Yeon;Jeon, Jae-Sik;Kim, Jae Kyung
    • Mycobiology
    • /
    • 제44권2호
    • /
    • pp.99-104
    • /
    • 2016
  • Candida spp. is an invasive infectious fungus, a major risk factor that can increase morbidity and mortality in hospitalized patients. In this study, 2,508 Candida spp. were isolated from various clinical specimens collected from university hospitals from July 2011 to October 2014. They were identified in order to determine isolation frequencies and characteristics by specimen, gender, age group, year, season, and month. The strain-specific isolation rate of Candida spp. is in the order of Candida albicans (1,218 strains, 48.56%), Candida glabrata (416 strains, 16.59%), Candida utilis (305 strains, 12.16%), Candida tropicalis (304 strains, 12.12%), and Candida parapsilosis (116 strains, 4.63%) and these five species accounted for more than 94% of the total strains. Of the specimens, Candida spp. were most frequently isolated from urine-catheter, followed by urinevoided, blood, sputum, other, open pus, vaginal discharge, Tip, ear discharge, bronchial aspiration and bile, in that order. Looking at the age distribution, the detection rate of patients in their 60s and older was significantly higher at 75.8% (1,900/2,508). The detection rate of patients in their 20s and younger was shown to be very low at 2.55% (64/2,508). By year, the detection rate of non-albicans Candida spp. showed a tendency to gradually increase each year compared with C. albicans. As isolation of Candida spp. from clinical samples at the specie level can vary depending on characteristics of the patient, sample, season, etc., continual studies are required.