• Title/Summary/Keyword: Isolated power supply

Search Result 86, Processing Time 0.025 seconds

Seismic Performance Improvement of Base Isolated Buildings using Smart Passive Control System (스마트 수동 제어 시스템을 이용한 면진 건물의 내진 성능 개선)

  • Jung, Hyung-Jo;Jung, Chan-Kuk;Choi, Kang-Min;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.37-46
    • /
    • 2006
  • In this study, the efficacy of the newly developed smart passive control system to improve seismic performance of base isolated building structures is numerically verified. The smart passive control system consists of a magnetorheological (MR) damper and an electromagnetic induction (EMI) part. The damping characteristics of an MR damper can be controlled by the current generated in an EMI part according to the Faraday's law of electromagnetic induction. An EMI part consisting of a permanent magnet and a solenoid coil could substitute a control system including sensors, a controller and an external power supply in a conventional smart control system. The benchmark control problem for a base isolated building presented by the american society of civil engineers is considered for numerical simulation. The control performance of the smart passive control system is compared to that of the conventional smart control system using MR dampers. It is demonstrated from the numerical simulation results that the smart passive control system is useful to improve the seismic performance of base isolated buildings.

A Re-configurable 0.8V 10b 60MS/s 19.2mW 0.13um CMOS ADC Operating down to 0.5V (0.5V까지 재구성 가능한 0.8V 10비트 60MS/s 19.2mW 0.13um CMOS A/D 변환기)

  • Lee, Se-Won;Yoo, Si-Wook;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.60-68
    • /
    • 2008
  • This work describes a re-configurable 10MS/s to 100MS/s, low-power 10b two-step pipeline ADC operating at a power supply from 0.5V to 1.2V. MOS transistors with a low-threshold voltage are employed partially in the input sampling switches and differential pair of the SHA and MDAC for a proper signal swing margin at a 0.5V supply. The integrated adjustable current reference optimizes the static and dynamic performance of amplifiers at 10b accuracy with a wide range of supply voltages. A signal-isolated layout improves the capacitor mismatch of the MDAC while a switched-bias power-reduction technique reduces the power dissipation of comparators in the flash ADCs. The prototype ADC in a 0.13um CMOS process demonstrates the measured DNL and INL within 0.35LSB and 0.49LSB. The ADC with an active die area of $0.98mm^2$ shows a maximum SNDR and SFDR of 56.0dB and 69.6dB, respectively, and a power consumption of 19.2mW at a nominal condition of 0.8V and 60MS/s.

Investigation on Replacement Criteria for Aged Diesel Driven Power Generation Facility by Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 노후 디젤발전설비 교체기준 고찰)

  • Park, Myungsoo;Song, Gee Wook;Seo, Sang Il;Won, Dong Ju
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.2
    • /
    • pp.89-97
    • /
    • 2014
  • The diesel driven power generation facility provides most of electricity of island region where is isolated from the main land power supply system. It is possible to extend the life of diesel driven power generation facility by periodic maintenance. However, the long-term use of diesel driven power generation facility increases the operating cost due to aging hardware and reduced plant efficiency. In other words, on-time replacement of aging diesel driven power generation facility reduces plant operation cost. The purpose of this study presents major indicators to represent the characteristics of the diesel generator and conducts sensitivity analysis using Monte Carlo analysis. In addition, status core which indicates quantitatively the state of the diesel driven power generation facility is defined and prepare the replacement criteria based on the state score.

An Efficient Energy Charging Scheme for Wireless Sensor Networks Using a Mobile Sink Capable of Wireless Power Transmission

  • Park, Kyoung nam;Yoon, Ikjune
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.5
    • /
    • pp.1-9
    • /
    • 2019
  • In this paper, we propose the algorithms which determine 1) the efficient anchor-node visiting route of mobile sink in terms of energy supply and 2) the efficient energy amount to be charged to each anchor node, by using the information of each anchor node and the mobile sink. Wireless sensor networks (WSNs) using mobile sinks can be deployed in more challenging environments such as those that are isolated or dangerous, and can also achieve a balanced energy consumption among sensors which leads to prolong the network lifetime. Most mobile sinks visit only some anchor nodes which store the data collected by the nearby sensor nodes because of their limited energy. The problem of these schemes is that the lifetime of the anchor nodes can be shorten due to the increased energy consumption, which rapidly reduces the overall lifetime of WSN. This study utilizes a mobile sink capable of wireless power transmission to solve this problem, so a mobile sink can gather data from anchor nodes while charging energy to them. Through the performance verification, it is confirmed that the number of blackout nodes and the amount of collected data are greatly improved regardless of the size of the network.

Design and Development of 30W Military Grade DC-DC Converter for Guided Weapon and Aircraft (유도무기 및 항공기 탑재장비용 30W급 군사용 DC-DC 변환장치 개발)

  • Park, Sang-Min;Joo, Dong-Myoung;Chae, Soo-Yong;Kim, Hyung-Jung;Lee, Byoung-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1341-1350
    • /
    • 2017
  • In this paper, a high reliability 30W DC-DC converter is designed considering military standard (MIL-STD) for military applications such as guided weapon and aircraft. The performances and specifications of conventional military grade DC-DC converter are practically analyzed. The requirements for military grade DC-DC converter are established in consideration of MIL-STD and analysis results of conventional product. Two isolated DC-DC converter, forward and fly-back converter, are designed and compared to determine topology. From experimental results under various operating conditions, the forward topology satisfied performances and specifications of MIL-STD for military DC-DC converter.

The Characteristics Analysis of New Dc 48[V] Telecommunication Power System using Forward Type three Phase Rectifier (포워드형 3선 PWM 정류기를 이용한 새로운 DC 48[V] 통신용 전원시스템의 특성 해석)

  • Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • This paper proposed power system for new DC 49[V] telecommunication using forward three-phase PWM rectifier power factor and efficiency for improvement of ripple voltage. Proposed power system for DC 48[V] telecommunication that consists of power conversion devices including switch, inductor and condenser were made between each line, in power inverter device of each switch control turn-on in period of continuity time control to get power factor '1' of sine wave current and on-off of switch lessens peak current that was happened and got conversion efficiency 92.1[%] composing in PWM rectifier of forward form instead of general PWM rectifier. Also, harmonic input regulation value(IEC61000-3-2 Class-As) satisfy input current and reduce ripple factor of output voltage in state that distortion of three-phase supply is overlapped each other.

The small signal analysis of current-mode controlled converter (전류모드제어형 컨버터의 소신호 제어 특성)

  • Song, Yo-Chang;Kim, Young-Tae;Kim, Cherl-Jim
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.968-970
    • /
    • 2001
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$, from the experimental result with frequency response analyzer.

  • PDF

Characteristics and Implementation of LCL Type DC-DC Converter for Constant Voltage Power supply (LCL형 전압형 컨버터의 특성 분석 및 구현)

  • Park, Sangeun;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.260-267
    • /
    • 2015
  • An LCL-type isolated dc-dc converter is analyzed, using ac approximation. Analyses to express characteristics on the proposed converter are derived under steady and ideal elements conditions in this paper. The two operating modes can be identified from the analysis results representing different device conduction sequences. This converter is capable of achieving required output voltage(step up or down) operations with inductance ratio while operated at fixed frequency with constant duty ratio-50%. Experimental results show that the designed converter based on Q has zero voltage switching and constant output voltage at different load variations to verify the analysis.

A Study on an Ion Wind Created by a Wire Electrode and Parallel Plates Assembly (와이어 전극과 평행판에서 발생되는 이온풍 특성 연구)

  • 안영철;황필재;이재근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.318-323
    • /
    • 2004
  • When a strong electric field is applied between a sharply curved electrode and a blunt surface, the corona may result in a gas movement in the electrode gap which is directed toward the blunt surface. That is called the corona wind. It enhances heat and mass transfer between the surface and the surrounding gas. Moreover such enhancement causes no noise or vibration, which can be applied in complex, isolated geometries, and allows simple control of surface temperatures. This paper examines the relationship between the corona wind and the relative humidity. The facility consists of high voltage power supply thin tungsten wire, plate electrode, multimeter, microammeter and flow meter. Gas velocity is a linear function of voltage, relative humidity and is proportional to the square root of the current. The maximum velocities for the positive and negative corona discharge are 1.9 m/s (2.74 CMM/m), 1.5 m/s(2.15 CMM/m), respectively.

A study of stable output of solid-state laser through feedback control (Feedback 제어를 통한 고체 레이저의 출력특성 안정화에 관한 연구)

  • Song, K.Y.;Kwak, S.Y.;Hong, J.H.;Noh, K.K.;Kim, W.Y.;Kang, U.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1853-1855
    • /
    • 2002
  • A pulsed Nd:YAG laser is used widely in many applications such as materials processing, communications, military and medical instruments. It is important to control the laser energy in those fields with using a pulsed Nd:YAG laser. In this paper, constant-frequency current resonant half-bridge inverter and feedback control circuit are used to have output stable. This laser power supply is designed and fabri which was isolated. Also, this study is used an one-chip microprocessor, SCR, current transform A stable output of this Nd:YAG laser system investigated. The tested results are described.

  • PDF