• 제목/요약/키워드: Islanding phenomenon

검색결과 27건 처리시간 0.024초

분산형 태양광발전시스템의 단독운전 검출기법 (Anti-islanding method for distributed PV generation systems)

  • 황인호;안교상
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.64-67
    • /
    • 2005
  • Many anti-islanding methods have been developed and tested in pratice. Generally, it seems to be possible to include effective and reliable anti-islanding methods in the PV inverter However, it is difficult to detect islanding phenomenon in the case of multiple systems in the same distribution line. In this paper, the islanding possibility of distributed PV generation system is analyzed and discussed to detect islanding phenomenon.

  • PDF

유효전력변동방식을 이용한 새로운 단독운전 검출기법 연구 (A Novel Active Anti-islanding Method using Effective Power Variation)

  • 유병규;정영석;미키히코 마츠이;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.213-215
    • /
    • 2006
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent the phenomenon, various anti-islanding methods have been studied. This paper proposes the variation method of inverter output current magnitude to prevent the islanding phenomenon as a novel method, which causes the large frequency variation of inverter output voltage after islanding. Unlike most active anti-islanding method deteriorating power quality, this novel method will have high performance of islanding detection and good power quality. For the verification of the proposed method, the simulated result and analyses are presented.

  • PDF

병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석 (Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections)

  • 정영석;유병규;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.

Active Frequency Drift Method for Islanding Detection Applied to Micro-inverter with Uncontrollable Reactive Power

  • Kwak, Raeho;Lee, June-Hee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1918-1927
    • /
    • 2016
  • This paper proposes active frequency drift (AFD) as an anti-islanding method applied to micro-inverters with uncontrollable reactive power. When using ordinary inverter topologies, such as full bridge inverters in photovoltaic systems, the islanding phenomenon can be detected with reactive power-based methods, such as reactive power variation. However, when the inverter topology cannot control the reactive power, conventional anti-islanding methods with reactive power cannot be utilized. In this work, the topology used in this paper cannot control the reactive power. Thus, an anti-islanding method that can be used in topologies that cannot control the reactive power is proposed. The conventional anti-islanding method of the topology that cannot control reactive power is introduced and analyzed. Unlike the conventional AFD method, the proposed method extends a zero current interval every predetermined cycle. The proposed method offers certain advantages over conventional AFD methods, such as total harmonic distortion. The proposed method is validated through simulation and experiment.

고조파 주입에 의한 계통연계형 태양광발전시스템의 고립운전 검출 (Islanding Detection by Harmonic Current Injection Method for Utility Interactive Photovoltaic System)

  • 고재석;채영민;강병희;최규하
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.199-210
    • /
    • 2003
  • 본 논문에서는 계통연계형 태양광발전시스템의 고립운전방지를 위한 새로운 고리운전 검출기법을 연구한다. 이를 위하여 계통연계형 태양광발전시스템 및 고립운전시의 특성에 대하여 기술하였다. 또한 고립운전의 검출특성을 향상시키기 위한 새로운 검출기법을 제시하고 해석하였으며 검출시험을 위한 부하조건 선정을 위한 부하임피던스 곡선을 해석적으로 유포하였다 ACSL 시뮬레이션 및 실험을 통하여 제시한 고립운전 검출기법 및 해석결과를 검증하였다.

슬립모드 방식을 이용한 단독운전 검출기법의 모델링과 평가 (Modeling and Evaluation of Slip-Mode Frequency Shift Method for Anti-islanding Method)

  • 유병규;정영석;소정훈;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.520-522
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift (SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection zone (NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through the modeling and verified visually by simulation and experiment.

  • PDF

슬립모드 주파수변이 방식의 단독운전 검출법의 분석과 모델링 (Analysis and Modeling of Slip Mode Frequency Shift Method for Anti-islanding)

  • 유병규;정영석;소정훈;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1699-1701
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and rower supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift(SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection tone(NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through modeling and verified visually by simulation and experiment.

  • PDF

A Novel Active Anti-islanding Method for Grid-connected Photovoltaic Inverter

  • Jung, Young-Seok;Choi, Jae-Ho;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.64-71
    • /
    • 2007
  • This paper proposes a novel active frequency drift (AFD) method to improve the islanding detection performance with minimum current harmonics. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning the safety hazards and possible damage to other electric equipment, anti-islanding methods have been described. The AFD method that uses chopping fraction (cf) enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD method is inefficient and causes difficulty in designing the appropriate cf value to meet the limit of harmonics. In this paper, the periodic chopping fraction based on a novel AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also better performance of islanding detection compared with the conventional AFD method.

단독운전 방지를 위한 능동적 주파수 변환 기법의 검출 성능 및 THD 분석 (Detection Performance and THD Analysis of Active Frequency Drift for Anti-Islanding)

  • 조영민;최주엽;송승호;최익;이영권
    • 한국태양에너지학회 논문집
    • /
    • 제35권2호
    • /
    • pp.11-19
    • /
    • 2015
  • Islanding is a phenomenon that EPS(Electric Power System) is continuously energized by PV PCS(Photovoltaic Power Conditioning System) even when EPS is isolated from the grid. Unintentional islanding will result in safety hazard, power quality degradation and many other issues. So, islanding protection of grid-connected PV PCS is a key function for standards compliance. Nowadays, many anti-islanding schemes are researched. But existing anti-islanding schemes used in PV PCS have power quality degradation and non-detection zone issues. This paper analyses not only detection performance of existed anti-islanding schemes using active frequency drift but also THD of PCS output current according to each value disturbance for anti-islanding. In addition, the lowest value of disturbance in each scheme was tabulated under guarantee of anti-islanding condition.

A Study of Islanding Detection of Grid-connected Three-phase Photovoltaic Power Conditioning System

  • Jung Y.S.;Yu G.J.;Choi J.Y.;Choi J.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.761-764
    • /
    • 2003
  • Islanding phenomenon of a grid-connected photovoltaic (PV) power conditioning system (PCS) is said to occur if the PCS continues to power a section of the utility system after that section has been disconnected from the utility source. Since islanding creates hazards for personnel and equipment, PCSs are required to detect and prevent Et. In this paper, several islanding detection methods (IDMs) and reactive power variation method are described. Islanding test results for 9kW PCS are presented for verification.

  • PDF