A study of the Electron Beam Irradiator for Core-loss reduction of Grain-oriented silicon Steel

  • Kim Min;Yoon Jeong-Phil;Lee Gi-Je;Cha In-Su;Cho Sung-Oh;Lee Byeong-Cheol;Jeong Young-Uk;Yoo Jae-Gwon;Lee Jong-Min
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.93-97
    • /
    • 2001
  • A new compact, low-energy electron beam irradiator has been developed. The core-loss of silicon steels can be reduced by magnetic-domain refinement method. The irradiator was developed for the application of core-loss reduction using the method. The beam energy of the irradiator can be varied from 35 to 80 keV and the maximum current is 3mA. The irradiation area is designed to be $30\times30mm2$ now and will be upgraded to $30\times150mm2$ using a scanning magnet and scanning cone. The electron beam generated from 3 mm diameter LaB6 is extracted to the air for the irradiation of the silicon steels in the air. A special irradiation port was developed for this low-energy irradiator. A havar foil with $4.08{\mu}m$ thickness were used for the window and a cold air-cooling system keeps the foil structure by removing heat at the window. The irradiator system and its operation characteristics will be discussed.

  • PDF

유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가 (Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device)

  • 신상훈;이성현;손기홍;이현호;김금배;정해조;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.198-205
    • /
    • 2011
  • 감마선조사장치는 세포실험, 동물실험, 혈액방사선 조사, 선량측정 실험 및 교육 등에 널리 사용되고 있다. 한국원자력의 학원에서 보유하고 있는 Biobeam8000 (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs-137, 81.4 TBq) 감마선 조사장치는 7.5 L의 대용량과 넓은 영역에 사용이 가능한 감마선 조사장치이다. 비커 내부에 균일한 방사선조사를 위해 Cs-137 선원이 위아래 24 cm 범위를 일정한 주기로 왕복 이동하며, 기존의 다른 감마선 조사기와 같이 시료를 넣는 비커는 방사선 조사동안 360도 회전한다. 기존의 감마선 조사기와 달리 비교적 균일한 선량이 조사되는 반면에 방사선원이 이동하므로 위치에 따른 구체적인 선량정보도 필요로 하게 된다. 본 연구에서는 유리 선량계를 이용하여 Biobeam8000 감마선 조사장치의 비커 내부 선량을 측정하였고, 측정결과를 바탕으로 선량선형성과 선량재현성에 대한 평가 및 선량분포의 정보를 도출하였다. 이 결과를 바탕으로 실험 및 방사선 조사 시 효율적인 조사장치 사용을 위한 가이드라인을 제시하고자 한다.

40keV 저에너지 전자빔을 이용한 단결정 Si 태양전지의 변환 효율에 관한 연구 (Study about Conversion Efficiency of c-Si Solar Cells Using Low energy(40keV) Electron Beam)

  • 윤정필;강병복;박세준;윤필현;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.942-948
    • /
    • 2003
  • This paper about the small electron beam irradiator for solar cell's efficiency. Many things are studied by method to increase conversion efficiency of solar cell. We selected electron beam by method for conversion efficiency of solar cell. Energy bands of this electron beam irradiator is 80keV(max.). And, solar cells that apply in this paper are crystal Si. Average efficiency of solar cell that applies in this experiment is 10$\%$. This system manufactured low energy electron beam irradiator. And, electron beam irradiation to solar cell in vacuum chamber of this irradiator. Irradiation area is 20*20 [mm2] by 40[keV].

  • PDF

A proposed new configuration of a shuffle-dwell gamma irradiator

  • Wu, Hsingtzu
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3176-3180
    • /
    • 2022
  • A gamma irradiator is a well-developed installation for gamma radiation sterilization. A "shuffle-dwell" mode is preferable for high dose applications. A novel configuration of a shuffle-dwell gamma irradiator is proposed to increase energy utilization and throughput, which would result in higher profitability. While the minimum distance between any irradiation position and each source pencil, the minimum distance between the neighboring irradiation positions and the size of source pencils are kept the same as the current configuration, the irradiation positions and source pencils are rearranged based on the fact that radiation is emitted in an isotropic fashion. The computational results suggest that the proposed configuration requires an 8.7% smaller area and exposes the product to 11.8% more gamma radiation in a 10.7% shorter irradiation time. In other words, the proposed configuration needs a smaller area and shorter irradiation time to have a better performance compared to the current shuffle-dwell gamma irradiator. Note that the claim is based primarily on an analytical calculation. Experimental and manufacturing among other practical considerations will be taken into account in the future work to exhaustively evaluate the performance of the proposed configuration and to compare it with that of the traditional configuration.

다목적 방사선 조사장치 개발 및 선량분포특성 (The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution)

  • 이동훈;지영훈;이동한;김윤종;홍승홍
    • 전자공학회논문지SC
    • /
    • 제39권6호
    • /
    • pp.42-48
    • /
    • 2002
  • 다목적 방사선 조사장치의 설계, 제작 및 성능검사에 대해 기술하였다. 세슘-137을 사용한 다목적 방사선조사장치는 생물학에서 저선량 방사선에 대한 영향연구, 혹은 TLD(Thermo Luminescent dosimeter)의 교정을 위해 사용되어진다. 본 조사장치는 방사선 동위원소를 안전한곳에 저장하고 있다가 방사선조사시에만 조사실로 180도 회전하여 설정된 시간만큼 시료에 방사선 조사가 이루어 진 후, 사용이 끝나면 다시 차폐된 저장위치로 복귀하게된다. 제어시스템은 PLC 기반으로 구축하여 저선량율 조사장치의 시제품을 제작하였으며, 또한 컴퓨터를 통해 방사선 조사장치의 제어 및 세부 동작 상태 등을 실시간 검색, 원격제어 및 관리 할 수 있는 종합 관리 프로그램을 개발하였다. 조사실 내부 구성은 시료의 종류에 따라 최대 20RPM까지 다양하게 회전하면서 균일 조사될 수 있도록 조사실 및 챔버를 설계 제작하였으며, 조사실내 넣을 수 있는 조사체 최대 용량은 4.5리터이다. 조사실내의 방사선량의 분포도는 가프크로믹 필름을 사용하여 측정한 결과 2Ci 범위내에서 세슘-137의 경우 공기중에서 0.13cGy/min이었고 일반 물질과 등가인 물에서는 0.11cGy/min로 나타났으며, 오차는 약 ${\pm}$7%의 한도내에서 균일한 분포를 보였다. 또한 실제 누설선량은 조사실 밖 표면에서 최대 0.35mR/hr이였으며 1m 떨어진곳에서는 최대 0.03mR/hr로 허용치 이내였다.

유리선량계 지그를 이용한 혈액조사기의 정도관리 절차 초안 개발 (Development of Prototype Quality Assurance Procedure for Blood Irradiator Using Glass Dosimeter Jig)

  • 정동혁;강영록;문영민;김효진;곽동원;김정기;이만우
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.123-126
    • /
    • 2012
  • 혈액조사기의 정기적 정도관리를 위하여 일일, 월간 및 년간점검 항목을 개발하였다. 일일점검은 육안으로 기본적 작동을 점검하고, 월간과 년간점검은 자체 제작한 기구(유리선량계 지그)를 사용하여 조사 콘테이너에 대한 선량평가를 수행하도록 하였다. 본 연구에서 도출한 항목들은 임상적 차원에서 실용적이라고 평가한다.

백색 LED 조사의 상처 수복 효과 (Wound Recovery of Light Irradiation by White LED)

  • 천민우
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.42-46
    • /
    • 2011
  • Light can be divided into ultraviolet rays, visible rays, and infrared rays depending on the wavelengths. Visible rays with specific wavelength are those predominantly used for would treatment. Especially low level laser irradiates into cells, effectively stimulating cellular tissues and activating cellular function. This study was intended to verify the effect of white LED irradiation therapy on wound recovery in animal tests by applying white LED irradiator, which was independently designed and developed to emit beams of similar wavelength to that of a laser. The designed LED Irradiator was used to find out how white LED light source affected the skin wound of SD-Rat(Sprague-Dawley Rat). We divided the participants into two groups; white LED irradiation group which was irradiated 1 hour a day for 9 consecutive days, and none irradiation group. The results showed that the study group had lower incidence of inflammation and faster recovery, compared with the control group.

Cs-137 감마선에 대한 생물학 연구용 시료의 흡수선량 결정에 관한 연구 (Absorbed Dose Determination for a Biological Sample Irradiated by Gamma Rays from a Cs-137 Source)

  • 정동혁;김정기;양광모;주민수;김민영;이창열;김진호
    • 한국의학물리학회지:의학물리
    • /
    • 제22권3호
    • /
    • pp.124-130
    • /
    • 2011
  • 본 연구에서는 생물학 연구용 방사선 조사기(Gamma Irradiator, Chiyoda Technol Co., Japan)에서 방출되는 Cs-137 감마선에 대하여 선량자료 구축을 위한 선량평가를 수행하였다. 대상 시료는 직경 3 cm인 구형의 물로 가정하였으며 공기커마로부터 선량계산 체계에 따라 흡수선량을 결정하였다. 측정값의 평가를 위하여 이론적 계산 및 몬테칼로 계산(MCNPX)을 이용하여 상호 비교하였다. 측정한 공기커마는 선원과 200 cm 이내에서 이론적 계산과 3.1% 이내로 일치하였다. 최종 결정된 흡수선량은 몬테칼로 계산과 100 cm와 200 cm에서 각각 1.9% 및 3.7%의 차이를 보였다. 본 결과는 비록 단편적이지만 생물 실험용 자료구축을 위한 기초 결과로서 타당하며 추후 다양한 형태의 시료 조건에 대해서 연구를 진행해야 할 것이다.