• Title/Summary/Keyword: Irradiation Dose

Search Result 1,997, Processing Time 0.027 seconds

Electron Beam Effects on Lignin Stabilization during Carbonization

  • Lee, Byoung-Min;Kang, Phil-Hyun;Jeun, Joon-Pyo
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.167-170
    • /
    • 2013
  • Lignin can be a valuable natural chemical resource. Structurally, lignin is a three-dimensional polymer made up of condensed C-C bonds and some ether linkages, most of which are not readily degraded. In this study, lignin carbonization under various electron beam pretreatment conditions was characterized through a thermogravimetric analysis (TGA), X-ray diffraction (XRD) and Raman spectroscopy. Lignin stabilization was controlled by various doses of electron beam irradiation corresponding to 50, 100, 200, 500 and 1,000 kGy; the carbonization process was performed under a nitrogen gas atmosphere at $1000^{\circ}C$ for 1 h. The TGA results showed that a 1,000 kGy lignin dose increased the residue weight from 39.96% to 45.23%, compared to non-irradiated lignin. This observation is in agreement with the XRD and Raman spectroscopy results, in which the two theta degrees and the degree of crystallization were improved by increasing the electron beam irradiation.

Effects of Ultraviolet Blood Irradiation in a Type 1 Diabetic Rabbit (제1형 당뇨토끼에서 자외선 혈액 조사 효과)

  • Yang, Yeong-Seok;Kim, Gi-Beum
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.3
    • /
    • pp.81-96
    • /
    • 2019
  • The purpose of this study is to evaluate the effects of ultraviolet blood irradiation on the blood when a low dose of ultraviolet (UV) C is directly irradiated to the blood in a diabetic rabbit model and to evaluate the effects on treatment for diabetes. This study results indicate that the reduced body weight is increased and blood glucose levels are significantly reduced after the UBI treatment is performed when compared to those prior to the UBI treatment. In addition, $HCO_3{^-}$ levels and blood pH were elevated and lowered, respectively. When the UBI treatment is performed in a diabetic rabbit model, in this result indicate that blood glucose levels are reduced.

Study on changes in electrical and switching characteristics of NPT-IGBT devices by fast neutron irradiation

  • Hani Baek;Byung Gun Park;Chaeho Shin;Gwang Min Sun
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3334-3341
    • /
    • 2023
  • We studied the irradiation effects of fast neutron generated by a 30 MeV cyclotron on the electrical and switching characteristics of NPT-IGBT devices. Fast neutron fluence ranges from 2.7 × 109 to 1.82 × 1013 n/cm2. Electrical characteristics of the IGBT device such as I-V, forward voltage drop and additionally switching characteristics of turn-on and -off were measured. As the neutron fluence increased, the device's threshold voltage decreased, the forward voltage drop increased significantly, and the turn-on and turn-off time became faster. In particular, the delay time of turn-on switching was improved by about 35% to a maximum of about 39.68 ns, and that of turn-off switching was also reduced by about 40%-84.89 ns, showing a faster switching.

The Effects of ${\gamma}-rays$ on Power Devices

  • Lho, Young-Hwan;Kim, Ki-Yup;Cho, Kyoung-Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2287-2290
    • /
    • 2003
  • The electrical characteristics of power devices such as BJT (Bipolar Junction Transistor), and MOSFET (Metal Oxide Field Effect Transistor), etc, are altered due to impinging photon radiation and temperature in the nuclear or the space environment. In this paper, BJT and MOSFET are the two devices subjected to ${\gamma}$ radiation. In the case of BJT, the current gain (${\beta}$) and the collector to Emiter breakdown voltage ($V_{CEO}$) are the two main parameters considered. When it was subjected to ${\gamma}$ rays, the ${\beta}$ decreases as the dose level increases, whereas, $V_{CEO}$ gradually increases as the dose level increases. In the case of MOSFET, the threshold voltage is decreasing as the dose level increases. Here it has been observed the decent rate is an increasing function of the threshold voltage. The on-resistance does not change with respect to the dose. Both the devices recover back the original specification after the annealing is finished. No permanent damage has been occurred.

  • PDF

Development of p-MOSFET Type Accumulated Radiation Dose Monitoring Sensor (p-MOSFET 타입 방사선 누적선량 모니터링 센서 개발)

  • 이남호;최영수이용범육근억
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.597-600
    • /
    • 1998
  • When a semiconductor(pMOSFET) sensor is exposed to ionizing radiation, electrons/holes are generated in its oxide layer. By the phenomenon of hole traps in oxide layer during their move, the characteristics of semiconductor is changed. This paper describes the output characteristic changes of two kind of pMOSFET(domestic, japan) after C0-60 ${\gamma}$-irradiation on them for their application as radiation accumulated dose monitoring sensors. We found the threshold voltage shifts (VT) of pMOSFETs in proportion to irradiated radiation dose and their linear properties. These results make us confirm that we will be able to develop good accumulated radiation dose monitoring sensors.

  • PDF

The Effects of Nanoparticles for Irradiation (방사선조사에서 나노 입자 혼합물의 영향)

  • Yea, Ji-Woon;Shin, Hyun-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.28 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • Background: To evaluate the changes in the radiation dose and temperature distribution on irradiated egg albumin and nanoparticle ($Fe_3O_4$) powder mixed egg albumin. Methods: A new type of phantom was designed by fabricating a $30{\times}30{\times}30cm$ acryl square inside a $3{\times}3{\times}3cm$ small square and dividing it into two parts. In the control group, only egg albumin was irradiated, and in the test group, 25 nm 20 mg/cc, 25 nm 40 mg/cc, and 1 um 40mg/cc nanoparticles with egg albumin were irradiated. The radiation isodose distributions and temperature changes were then observed. Results: No significant changes were observed in the radiation dose and temperature distribution. Conclusion: The nanoparticles were considered not to have had any effect on the radiation dose and temperature distribution under the experimental conditions. Further studies can be conducted based on the changes in the mixture material.

  • PDF

Analysis of High Luminance LED Beam Degradation using Color CCD Image (칼라 CCD 영상을 이용한 고휘도 LED 전구의 빔 열화 분석)

  • Cho, Jai-Wan;Choi, Young-Soo;Lee, Jae-Chul;Koo, In-Soo;Hong, Seok-Boong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.6
    • /
    • pp.586-591
    • /
    • 2010
  • VLC (Visible Light Communication) is a wireless communication method using light that is visible to the human eye. It has a major advantage that it causes no interference to RF-based devices. This makes wireless communication possible in RF hazardous areas such as nuclear facilities. In order to apply VLC communication in harsh environment of nuclear power plant, the high luminance LEDs, which are key components of the VLC communication, have been gamma-ray irradiated at the dose rate of 4kGy/h during 72 hours up to a total dose of 288 kGy. The radiation induced color-center was formed in the LED housing cap made of transparent plastic or acryl material. The beam degradations of high luminance LEDs by high dose-rate gammaray irradiation are analyzed using color CCD image processing technology.

Brachytherapy for Head and Neck Cancer (두경부암의 근접방사선 치료)

  • Yoo Seong-Yul
    • Korean Journal of Head & Neck Oncology
    • /
    • v.7 no.1
    • /
    • pp.3-9
    • /
    • 1991
  • Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. The main characteristics of brachytherapy are delivering of higher dose to target volume shortening of total treatment period and sparing of normal tissue. Recent development of iridium ribbons for low dose rate implant provides improvement of technology of brachytherapy in terms of safety and efficiency. High dose rate method. on the other hand, is effective to avoid unnecessary expoure of medical personnel.

  • PDF

Dobe Contamination by Tangential Irradiation of Breast Cancer (유방암의 방사선 절선조사에 의한 선량분포)

  • Lee Jong Gul;Lee Byung Jun;Lee Ho Soo;Lee Byung Je
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.67-70
    • /
    • 1994
  • The use of primary breast irraditation with advantage of improved cosmesis in breast cancer may be the potential risks of radiation for a change in the number of normal breast cancers and lung fibrosis. The magnitude of the scattered dose for a variety of radiation treatment techniques from patient of breast cancer and phantom was measured by adequate dosimeters. We can reduce the dose of the normal breast to treated with radiation by understanding the factors contributing to the unwanted dose and by determining ways to decrease this dose.

  • PDF

A Dual Radiation Monitoring System Ror Robot Working in High Radiation Field (고방사선장내 작업 로봇용 이중 방사선 감지 시스템)

  • Lee Nam-Ho;Cho Jai-Wan;Kim Seung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.556-558
    • /
    • 2005
  • The effect of high irradiation on inspection systems in a nuclear power plant can be severe, especially to electronic components such as control hoards. The effect may lead to a critical malfunction or trouble to a underwater robot for inspection and maintenance of nuclear reactor. However, if information on the total accumulated dose on the sensitive parts of the robot is available, a prediction of robot's behavior in radiation environments becomes possible. To know how much radiation the robot has encountered, a dosimeter to measure the total accumulated dose is necessary. This paper describes the development effort of a dual radiation monitoring system using a SiC diode as a dose-rate meter and a p-type power MOSFET as a dose meter. This attempt using two sensors which detect same radiation improves reliability and stability at high intensity radiation detection in nuclear facilities. It uses the concept of diversity and redundancy.