• 제목/요약/키워드: Irradiation Dose

검색결과 1,987건 처리시간 0.024초

자궁경암(子宮頸癌) 방사선치료(放射線治療)에 의한 직장손상(直腸損傷) (Rectal Injuries after Radiotherapy for Carcinoma of the Uterine Cervix)

  • 김정진
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.103-109
    • /
    • 1983
  • 47 out of 56 cases of intact uterine cervix cancer treated by radiation at the Hanyang University Hospital were followed 18 months or more after treatment. (7 patients died before 18 months, 2 cases lost to follow-up). Age distribution reveal 5 cases in 30's, 18 cases in 40's, 17 cases in 50's, 7 cases in 60's. Histologically, all cases were squamous cell type except one case of adenocarcinoma. 1. 45 cases were treated by combined external Co-60 irradiation and intracavitary irradiation by Cs-137 small sources. 1 case was treated by external irradiation only, and 1 case by intracavitary only. 2. Rectal injuries were observed in 13 cased (27.6%), 4 cases in Grade 1, 8 cased in Grade 2 and 1 cases in Grade 3 which needed surgical management. 3. Average intervals of rectal injury following treatment was 9.2 months varying from 5 to 15 months. 4. Relation between rectal injury and point A dose reveal 6 cases between 7000-7999 rad and 6 cases between 8000-8999 rad and 1 case above 9000 rad. Even though there is no direct relation between point A dose and rectal injury, it is expected that rectal injury increases as point A dose increase. 5. In the normal condition, rectal injury can't be attributed to one major cause. Radiation dose, small source distribution, general condition of patients, local anatomy of the individual patient, history of PID and previous surgery, all play complex roles.

  • PDF

A Smart Setup for Craniospinal Irradiation

  • Peterson, Jennifer L.;Vallow, Laura A.;Kim, Siyong;Casale, Henry E.;Tzou, Katherine S.
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.230-236
    • /
    • 2013
  • Our purpose is to present a novel technique for delivering craniospinal irradiation in the supine position using a perfect match, field-in-field (FIF) intrafractional feathering, and simple forward-optimization technique. To achieve this purpose, computed tomography simulation was performed with patients in the supine position. Half-beam, blocked, opposed, lateral, cranial fields with a collimator rotation were matched to the divergence of the superior border of an upper-spinal field. Fixed field parameters were used, and the isocenter of the upper-spinal field was placed at the same source-to-axis distance (SAD), 20 cm inferior to the cranial isocenter. For a lower-spinal field, the isocenter was placed 40 cm inferior to the cranial isocenter at a constant SAD. Both gantry and couch rotations for the lower-spinal field were used to achieve perfect divergence match with the inferior border of the upper-spinal field. A FIF technique was used to feather the craniospinal and spinal-spinal junction daily by varying the match line over 2 cm. The dose throughout the target volume was modulated using the FIF simple forward optimization technique to obtain homogenous coverage. Daily, image-guided therapy was used to assure and verify the setup. This supine-position, perfect match craniospinal irradiation technique with FIF intrafractional feathering and dose modulation provides a simple and safe way to deliver treatment while minimizing dose inhomogeneity.

Preparation and Characterization of pH-Sensitive Poly(ethylene oxide) Grafted Methacrylic Acid and Acrylic Acid Hydrogels by ${\gamma}-ray $ Irradiation

  • Lim, Youn-Mook;Lee, Young-Moo;Nho, Young-Chang
    • Macromolecular Research
    • /
    • 제13권4호
    • /
    • pp.327-333
    • /
    • 2005
  • pH-sensitive hydrogels were studied as a drug carrier for the protection of insulin from the acidic environment of the stomach before releasing it in the small intestine. In this study, hydrogels based on poly(ethylene oxide) (PEO) networks grafted with methacrylic acid (MAA) or acrylic acid (AAc) were prepared via a two-step process. PEO hydrogels were prepared by ${\gamma}-ray $ irradiation (radiation dose: 50 kGy, dose rate: 7.66 kGy/h), grafted by either MAA or AAc monomers onto the PEO hydrogels and finally underwent irradiation (radiation dose: 520 kGy, dose rate: 2.15 kGy/h). These grafted hydrogels showed a pH-sensitive swelling behavior. The grafted hydrogels were used as a carrier for the drug delivery systems for the controlled release of insulin. Drug-loaded hydrogels were placed in simulated gastric fluid (SGF, pH 1.2) for 2 hr and then in simulated intestinal fluid (SIF, pH 6.8). The in vitro drug release behaviors of these hydrogels were examined by quantification analysis with a UV-Vis spectrophotometer.

한국인 다소비 섭취 식품의 방사선 조사후 항산화 영양소와 비타민 $B_1$의 변화 (Changes in Antioxident Nutrients and Vitamin $B_1$ Contents of Gamma Irradiated Foods Consumed most Frequently in Korea)

  • 장현희;남혜선;이선영
    • Journal of Nutrition and Health
    • /
    • 제37권1호
    • /
    • pp.38-44
    • /
    • 2004
  • Food irradiation has been steadily increased in many countries concomitantly with increasing international trades and concerns about naturally occurring harmful contaminants of food. Although, irradiation provides an excellent safeguard for the consumer by destroying harmful bacteria, it would be necessary to investigate nutritional adequacy of irradiated foods with a special emphasis on such foods as red pepper powders, cold-water fishes (mackerel), sesame seeds that are widely consumed in Korea. These food items are of special concern due to the fact that most of them are imported and that several nutrients contained in them are sensitively reacting to irradiation. We observed changes in the antioxidant nutrients contents, such as vitamin A, $\beta$-carotene, vitamin C and total phenol, and also vitamin B$_1$ in the foods that were irradiated at different dose levels. The nutrients contents in red pepper were respectively 98.6% and 92.3% for total phenol, and 97.8% and 94.5% for $\beta$-carotene, right after irradiation at the dose of 10 and 20 kGy. The vitamin C contents decreased with irradiation doses up to 76.4% (10 kGy) and 68.5% (20 kGy) and B$_1$ contents decreased to 54.9% and 80.7% of non irradiated red pepper. When the mackerel was irradiated at the applied dose of 3 and 7 kGy, total phenol concentration of the irradiated fish was respectively 91.3% and 94.2% of non irradiated fish. The amounts of vitamin A were 82.6% (3 kGy) and 78.0% (7 kGy) of unirradiated sample and vitamin B$_1$ contents reduced to 30.5% and 51.5%. $\alpha$-Tocopherol content was 33.9% of the non-irradiated one when it was irradiated at 7 kGy. Vitamin A and ${\gamma}$-tocopherol contents in sesame seeds linearly decreased with the applied doses (5 and 10 kGy) Vitamin A contents decreased up to 87.8% (5 kGy) and 82.9% (10 kGy) and that of ${\gamma}$-tocopherol were 72.4% and 66.5% of the unirradiated sample.

고선양(高線量) 방사선(放射線)이 백혈구(白血球) 수명(壽命)에 미치는 영향(影響) (Effects of High Dose Irradiation on The Leukocyte Life Span)

  • 고주환;정인용;김용규
    • Journal of Radiation Protection and Research
    • /
    • 제9권2호
    • /
    • pp.67-75
    • /
    • 1984
  • As a part of studies on acute effects of high dose irradiation the present report was carried out to evaluate the changes of the leukocyte life span in the Newzealand white male rabbits by a single whole body exposure to gamma rays from $^{60}Co$ teleirradiation unit. The exposure was done in dose levels of 100, 300, 550 and 1,000 rad to each experimental group of 10 rabbits. The life span and apparent half survival time of leukocytes, and the elution rate of leukocytes in the circulating blood were measured by McMillan method using $^{51}Cr$. 1. As a critical indicator of radiation hazards of the Newzealand male rabbits, the LD 50/30 and LD 100/30 after whole body exposure was estimated as 550 and 1,000 rads respectively. 2. The life span of leukocyte in the circulation after irradiation was slightly shortened in the 100 rad irradiated group, as compared with the unirradiated control group, but markedly shortened in the 300, 550 and 1,000 rads irradiated group. 3. After irradiation, decrease of leukocyte half survival time in the circulation showed the same pattern as that of leukocytes life span. 4. As the irradiation doses increased, the elution rate of $^{51}Cr$ loss from $^{51}Cr$ tagged leukocytes in the circulation were markedly increased gradually. 5. The life span shortening of leukocytes in the circulation after irradiation seems to occure by two processes of senescence acceleration and early destruction.

  • PDF

감마선을 이용한 변성전분의 개발 (Development of Modified Starch by Gamma Irradiation)

  • 강일준;변명우
    • 한국식품과학회지
    • /
    • 제28권3호
    • /
    • pp.514-520
    • /
    • 1996
  • 감마선 조사기법을 사용하여 새로운 건식공정의 공업용 변성전분 생산 기술개발을 위한 기초연구로서, 시판 옥수수 전분에 직접 감마선을 조사하여 감마선 조사 전분(0-110 kGy)의 이화학적 성질을 검토하였다. 감마선 조사선량이 증가함에 따라 blue value가 직선적으로 감소하였으며, alkali number와 용해도는 크게 증가하였다. $65-95^{\circ}C.$의 온도범위에서 전분용액의 광투과도 또한 감마선 조사선량이 증가함에 따라 현저히 증가하였으며, 물결합능력과 팽윤력은 각각 30 kGy 및 10kGy에서 최대값을 나타내다가 다시 감소하는 경향을 나타내었다. 비조사 전분에 비해 감사선 조사 전분의 호화점도는 현저한 감소 현상을 나타내었다. peak 점도의 경우 7,000 B.U.(비조사 전분)에서 60 B.U.(110kGy)로 그 값이 100배 이상 현저히 감소하였으며 $30^{\circ}C$의 냉각점도도 약 300배 이상 급격한 감소를 나타내었다. 현재 시판중인 산처리 전분은 30kGy의 감마선조사 전분과 유사한 특성을 나타내었으며, 산화전분은 100kGy의 감마선 조사전분과 유사한 성질을 나타내었다.

  • PDF

감마선을 조사한 시판 도토리묵의 저장 중 품질 특성 (Quality Characteristics of Gamma Irradiated Commercial Arcon Starch Gel during Storage)

  • 김민희;김현주;허옥순;이주운;변명우;김미리
    • 동아시아식생활학회지
    • /
    • 제17권6호
    • /
    • pp.816-821
    • /
    • 2007
  • The physical properties and sensory characteristics of acorn starch gels (Dotori Mook), which were gamma-irradiated up to 3 kGy, were evaluated during storage at $4^{\circ}C$. Even at the dose of 2 kGy, the gamma irradiation decreased total bacteria in the Dotori Mook during 5 days of storage, to lower than the detection limit $(10^2CFU/g)$. The hardness of the control sample increased according to the days of storage, while the gamma irradiated samples had decreased hardness according to the irradiation dose. The sample irradiated at 3 kGy maintained the same hardness as the control at day 0 of storage. Irradiation did not affect the Hunter color values. No significant differences were observed in off-odor, color, springiness, and overall acceptability (p<0.05) at the irradiation dose of 2 kGy. It can be concluded that the irradiation of Dotori Mook, up to 2 kGy, does not affect the quality of the Mook during storage, with regard to texture and sensory characteristics. Moreover, the irradiated Mook was superior in maintaining hardness and had prolonged shelf-life time by sanitation.

  • PDF

쌀기본 이유식의 에너지 밀도 및 저장성 증대를 위한 최적 감마선 조사 선량 (Optimum of Gamma Irradiation Dose for Rice-based Infant Foods with Improved Energy-density and Shelf-life)

  • 이유석;오상희;이주운;김장호;김재훈;김관수;김왕근;변명우
    • 한국식품영양과학회지
    • /
    • 제33권5호
    • /
    • pp.894-898
    • /
    • 2004
  • 본 연구에서는 방사선 조사 기술을 이용하여 에너지 밀도가 증대되고 미생물학적으로 안전한 이유식의 공급을 위해 쌀미음의 적절한 방사선 조사 시기 및 선량을 결정하였다. 쌀과 쌀미음에 각각 0, 2.5, 5, 7.5, 10, 15, 20 kGy로 감마선 조사한 후 물성특성과 총균수를 측정하였다. 쌀과 쌀미음에 2.5 kGy선량으로 감마선 조사하는 경우 점성이 각각 22%, 98%로 감소하였다. 저장 2주째 비조사구의 총균수는 6 log CFU/g이었으나, 2.5 kGy 조사구의 경우 3 log CFU/g 수준을 유지하였으며 7.5 kGy 조사구의 경우 저장기간 동안 어떠한 미생물도 검출되지 않았다. 따라서 총고형분 함량을 증대시키기 위해서는 점성저하와 미생물학적인 측면을 고려하여 쌀미음 상태에서 감마선 조사하는 것이 적절할 것으로 사료되며, 이유식의 에너지밀도를 증대시키기 위한 기술의 일환으로 감마선 조사 기술의 이용가능성을 시사하는 바이다.

Deuterium ion irradiation impact on the current-carrying capacity of DI-BSCCO superconducting tape

  • Rajput, M.;Swami, H.L.;Kumar, R.;Bano, A.;Vala, S.;Abhangi, M.;Prasad, Upendra;Kumar, Rajesh;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2586-2591
    • /
    • 2022
  • In the present work, we have irradiated the DI-BSCCO superconducting tapes with the 100 keV deuterium ions to investigate the effect of ion irradiation on their critical current (Ic). The damage simulations are carried out using the binary collision approximation method to get the spatial distribution and depth profile of the damage events in the high temperature superconducting (HTS) tape. The point defects are formed near the surface of the HTS tape. These point defects change the vortex profile in the superconducting tape. Due to the long-range interaction of vortices with each other, the Ic of the tape degrades at the 77 K and self magnetic field. The radiation dose of 2.90 MGy degrades the 44% critical current of the tape. The results of the displacement per atom (dpa) and dose deposited by the deuterium ions are used to fit an empirical relation for predicting the degradation of the Ic of the tape. We include the dpa, dose and columnar defect terms produced by the incident particles in the empirical relation. The fitted empirical relation predicts that light ion irradiation degrades the Ic in the DI-BSCCO tape at the self field. This empirical relation can also be used in neutron irradiation to predict the lifetime of the DI-BSCCO tape. The change in the Ic of the DI-BSCCO tape due to deuterium irradiation is compared with the other second-generation HTS tape irradiated with energetic radiation.

Prediction of Midline Dose from Entrance and Exit Dose Using OSLD Measurements for Total Body Irradiation

  • Choi, Chang Heon;Park, Jong Min;Park, So-Yeon;Chun, Minsoo;Han, Ji Hye;Cho, Jin Dong;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.77-82
    • /
    • 2017
  • Background: This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). Materials and Methods: For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. Results and Discussion: The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. Conclusion: The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.