• 제목/요약/키워드: Irradiation Dose

검색결과 1,996건 처리시간 0.038초

Fabrication of ZnO inorganic thin films by using UV-enhanced Atomic Layer Deposition

  • 송종수;윤홍로;성명모
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.312.1-312.1
    • /
    • 2016
  • We have deposited ZnO thin films by ultraviolet (UV) enhanced atomic layer deposition using diethylznic (DEZ) and water (H2O) as precursors with UV light. The atomic layer deposition relies on alternating dose of the precursor on the surface and subsequent chemisorption of the precursors with self-limiting growth mechanism. Though ALD is useful to deposition conformal and precise thin film, the surface reactions of the atomic layer deposition are not completed at low temperature in many cases. In this experiment, we focused on the effects of UV radiation during the ALD process on the properties of the inorganic thin films. The surface reactions were found to be complementary enough to yield uniform inorganic thin films and fully react between DEZ and H2O at the low temperature by using UV irradiation. The UV light was effective to obtain conductive ZnO film. And the stability of TFT with UV-enhanced ZnO was improved than ZnO by thermal ALD method. High conductive UV-enhanced ZnO film have the potential to applicability of the transparent electrode.

  • PDF

Chondroitin sulfate and Phelinus linteus mushroom : skin whitening

  • 하배진;황일영;이창훈;정영기;강환열
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.791-795
    • /
    • 2001
  • This study was conducted to develop a new biomaterial to be used for skin whitening. The melanin elimination effect of chondroitin sulfate and phelinus linteus mushroom in rabbit back skin were evaluated. Rabbit dorsum was exposed to chronic UV irradiation(320nm) once daily for 30 days after initial melanin injection (100mg/kg). And then, chondroitin sulfate and phelinus linteus mushroom at dose of 0.7g for 30days were applied on the zone. The dorsal skin was histologically examined. Furthermore, we investigated free-radical extinction effect, antioxidation and tyrosinase activity inhibition effects. The histological study indicated that chondroitin sulfate and phelinus linteus mushroom decreasd melanine pigment significantly. As a result, chondroitin sulfate and phelinus linteus mushroom have a remarkable effect on the skin whitening by melanin elimination.

  • PDF

FISH(Fluorescence in situ hybridization)를 이용하여 분석한 방사선에 의해 유발된 림프구의 염색체 이상 (Radiation induced Chromosome aberration in human Iymphocyte detected by Fluorescence in sifu hybridization)

  • 정해원;손은희;기혜성;하성환
    • 한국환경성돌연변이발암원학회지
    • /
    • 제16권2호
    • /
    • pp.88-96
    • /
    • 1996
  • Fluorescence in situ hybridization (FISH) with the DNA probe for human chromosome 4 was used to analyse in vitro radiation induced chromosome rearrangement in peripheral lymphocyte. Translocations, dicentrics, acentrics and color junctions involving the painted chromosome were scored according to the Protocol for Aberration Identification and Nomenclature Terminology (PAINT) system. The frequency of chromosome rearrangements including reciprocal translocation, dicentric, acentric fragment and color junction increased with radiation dose. The frequency of dicentric chromosome reduced by the fixation time following irradiation, whereas that of translocation was relatively persistent. The applicability of FISH for scoring stable translocation for biological dosimetry was demonstrated.

  • PDF

방사선 처리에 의한 선충 방제 효과 (Experimental Study on Physical Control of Nematodes Using The Ionizing Radiation)

  • 이재광;유대현;이면주
    • 한국환경과학회지
    • /
    • 제14권12호
    • /
    • pp.1113-1117
    • /
    • 2005
  • Gamma-ray treatment was used to exterminate nematodes, which were harmful to agriculture When gamma-ray at the dose range of $5\~75$ kGy was irradaidated, nematodes were reduced by $40\~50\%$ When irradiated over 30 kGy, almost nematodes were non-mobile and fluorochromatic reactions showed that $60\;\~80\%$ of nematodes with non-mobility died after irradiation. The results of electron spin resonance spectroscopy suggested that radicals generated by radiolysis could damage to nematodes.

원발성 종격동 정상피종: 1례 보고 (Primary Mediastinal Seminoma: A Case Report)

  • 이인성;김형묵
    • Journal of Chest Surgery
    • /
    • 제11권2호
    • /
    • pp.170-174
    • /
    • 1978
  • A case of mediastinal seminoma is presented. A male driver, 27 years old Korean, has been suffered from substernal pain, cough and moderate swallowing difficulty since 5 months prior to this admission. At the time of onset, he visited at a local clinic to find some mass in his anterior mediastinum on chest P-A and lateral X-ray check. Recently, intermittent hiccups with much aggravated dysphagia forced him to visit our hospital, and admitted for radical resection under the impression of anterior superior mediastinal tumor of thymus origin. Median sternotomy was done and total resection of the tumor of 8.0X11.0X3.5cm was done without any specific complication and biopsy of the tumor revealed as primary mediastinal seminoma of the mediastinum. Supplementary prophylactic irradiation therapy was done with a tumor dose of 4,000 rad in 4 weeks after operation. Postoperative hospital course was uneventful and patient was joyful with his occupation for 3 months after discharge.

  • PDF

Co60 Gamma-Ray Effects on the DAC-7512E 12-Bit Serial Digital to Analog Converter for Space Power Applications

  • Shin, Goo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2065-2069
    • /
    • 2014
  • The DAC-7512E is a 12-bit digital to analog converter that is low power and a single package with internal buffers. The DAC-7512E takes up minimal PCB area for applications of space power electronics design. The spacecraft mass is a crucial point considering spacecraft launch into space. Therefore, we have performed a TID test for the DAC-7512E 12-bit serial input digital to analog converter to reduce the spacecraft mass by using a low-level Gamma-ray irradiator with $Co^{60}$ gamma-ray sources. The irradiation with $Co^{60}$ gamma-rays was carried out at doses from 0 krad to 100 krad to check the error status of the device in terms of current, voltage and bit error status during conversion. The DAC-7512E 12-bit serial digital to analog converter should work properly from 0 krad to 30 krad without any error.

Feeder Pipe Inspection Robot with an Inch-Worm Mechanism Using Pneumatic Actuators

  • Choi, Chang-Hwan;Jung, Seung-Ho;Kim, Seung-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.87-95
    • /
    • 2006
  • The outlet feeder pipe thinning in a PHWR (Pressurized Heavy Water Reactor) is caused by a high pressure steam flow inside the pipe, which is a well known degradation mechanism called a FAC (Flow Assisted Corrosion). In order to monitor the degradation, the thickness of the outlet bends close to the exit of the pressure tube should be measured and analyzed at every official overhaul. This paper describes a mobile feeder pipe inspection robot that can minimize the irradiation dose to human workers by automating the measurement process. The robot can move by itself on the feeder pipe by using an inch worm mechanism, which is constructed by two gripper bodies that can fix the robot body on to the pipe, one extendable and contractible actuator, and a rotation actuator connected to the two gripper bodies to move forward and backward, and to rotate in a circumferential direction.

Pipe Inspection Robot Using an Inch-Worm Mechanism with Embedded Pneumatic Actuators

  • Choi, Chang-Hwan;Jung, Seung-Ho;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.346-351
    • /
    • 2005
  • The outlet feeder pipe thinning in a PHWR (Pressurized Heavy Water Reactor) is caused by high pressure steam flow inside the pipe, which is a well known degradation mechanism called FAC (Flow Assisted Corrosion). In order to monitor the degradation, the thickness of the outlet bends closed to the exit of the pressure tube should be measured and analyzed at every official overhaul. This paper develops a mobile feeder pipe inspection robot that can minimize the irradiation dose of human workers by automating the measurement process. The robot can move by itself on the feeder pipe by using an inch worm mechanism, which is constructed by two gripper bodies that can fix the robot body on the pipe, one extendable and contractable actuator, and a rotation actuator connected the two gripper bodies to move forward and backward, and to rotate in the circumferential direction

  • PDF