Effects of radiation therapy on the dislocation resistance of root canal sealers applied to dentin and the sealer-dentin interface: a pilot study

  • Pallavi Yaduka;Rubi Kataki;Debosmita Roy;Lima Das;Shachindra Goswami
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.22.1-22.12
    • /
    • 2021
  • Objectives: This study evaluated and compared the effects of radiation therapy on the dislocation resistance of AH Plus and BioRoot RCS applied to dentin and the sealer-dentin interface. Materials and Methods: Thirty single-rooted teeth were randomly assigned to 2 groups (n = 15 each): AH Plus (Dentsply DeTrey) and BioRoot RCS (Septodont). Each group was subdivided into control and experimental groups. The experimental group was subjected to a total radiation dose of 60 Gy. The root canals of all samples were cleaned, shaped, and obturated using the single-cone technique. Dentin slices (1 mm) were sectioned from each root third for the push-out test and scanning electron microscopy (SEM) was done to examine the sealer-dentin interface. The failure mode was determined using stereomicroscopy. Bond strength data were analyzed by the independent t-test, 1-way analysis of variance, and the Tukey post hoc test (α = 0.05). Results: Significantly lower bond strength was observed in irradiated teeth than non-irradiated teeth in the AH Plus group (p < 0.05). The BioRoot RCS group showed no significant reduction in bond strength after irradiation (p > 0.05) and showed a higher post-irradiation bond strength (209.92 ± 172.26 MPa) than the AH Plus group. SEM revealed slightly larger gap-containing regions in irradiated specimens from both groups. Conclusions: The dislocation resistance of BioRoot RCS was not significantly changed by irradiation and was higher than that of AH Plus. BioRoot RCS may be the sealer of choice for root canal treatment in patients undergoing radiation therapy.

Inhibitory Effects of Collagen Coated Coffee Bean Intake on Skin Aging

  • Lee, In-Ah;Ha, Mi-Ae;Shin, Yong-Wook
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.1
    • /
    • pp.39-52
    • /
    • 2019
  • To evaluate the protective effect of collagen peptide-coated coffee extract on skin aging, cell viability was measured with a MTT assay using cultured CCD-986sk fibroblasts, and its effect on wrinkles in the skin of hairless mice induced by UVB-irradiation was examined. In addition, its effect on procollagen synthesis and anti-oxidative, and its inhibitory activity against collagenase, elastase, tyrosinase and MMP-1 were analysed. After the 30-minute topical treatment, the animals were exposed to UVB irradiation (60-100 mJ/cm2) for 4 weeks and its intensity increased during the period. Under the experimental conditions set in this study, the skin thickness of hairless mice significantly decreased (11.8-21.3%) compared to the control group. Based on these results, the prolonged oral intake of a collagen peptide mixture with coffee is expected to significantly increase the synthesis of procollagen in dermal fibroblasts, thereby contributing to the alleviation of wrinkling and lowered elasticity due to structural damage to the dermal layer caused by UV. The oral intake of collagen-coated coffee contributes to increasing collagen biosynthesis in a dose-dependent manner and alleviates the symptoms of thickened keratin caused by UV irradiation. However, it did not inhibit the enzymes involved in skin aging, whitening, wrinkle improvement, and antioxidation. Based on the these results, it can be concluded that the intake of collagen peptide-coated coffee extract can be utilized as an alternative material for the prevention or treatment of diseases associated with photoaging.

Ginseng root-derived exosome-like nanoparticles protect skin from UV irradiation and oxidative stress by suppressing activator protein-1 signaling and limiting the generation of reactive oxygen species

  • Wooram Choi;Jeong Hun Cho;Sang Hee Park;Dong Seon Kim;Hwa Pyoung Lee;Donghyun Kim;Hyun Soo Kim;Ji Hye Kim;Jae Youl Cho
    • Journal of Ginseng Research
    • /
    • v.48 no.2
    • /
    • pp.211-219
    • /
    • 2024
  • Background: Recently, plant-derived exosome-like nanoparticles (PDENs) have been isolated, and active research was focusing on understanding their properties and functions. In this study, the characteristics and molecular properties of ginseng root-derived exosome-like nanoparticles (GrDENs) were examined in terms of skin protection. Methods: HPLC-MS protocols were used to analyze the ginsenoside contents in GrDENs. To investigate the beneficial effect of GrDENs on skin, HaCaT cells were pre-treated with GrDENs (0-2 × 109 particles/mL), and followed by UVB irradiation or H2O2 exposure. In addition, the antioxidant activity of GrDENs was measured using a fluorescence microscope or flow cytometry. Finally, molecular mechanisms were examined with immunoblotting analysis. Results: GrDENs contained detectable levels of ginsenosides (Re, Rg1, Rb1, Rf, Rg2 (S), Gyp17, Rd, C-Mc1, C-O, and F2). In UVB-irradiated HaCaT cells, GrDENs protected cells from death and reduced ROS production. GrDENs downregulated the mRNA expression of proapoptotic genes, including BAX, caspase-1, -3, -6, -7, and -8 and the ratio of cleaved caspase-8, -9, and -3 in a dose-dependent manner. In addition, GrDENs reduced the mRNA levels of aging-related genes (MMP2 and 3), proinflammatory genes (COX-2 and IL-6), and cellular senescence biomarker p21, possibly by suppressing activator protein-1 signaling. Conclusions: This study demonstrates the protective effects of GrDENs against skin damage caused by UV and oxidative stress, providing new insights into beneficial uses of ginseng. In particular, our results suggest GrDENs as a potential active ingredient in cosmeceuticals to promote skin health.

Evaluation on the Applicability of Comet Assay for the Identification of Gamma-irradiated Frozen Beef Cut, Ground Beef and Tteokgalbi (감마선처리 냉동 우육, 분쇄우육 및 떡갈비의 판별을 위한 Comet assay의 적용성 평가)

  • Jong-Heum Park;Jae-Kyung Kim;Beom-Seok Song
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.257-264
    • /
    • 2023
  • This study was conducted to evaluate the applicability of the Comet assay, which is widely used for the identification of irradiated meats, to detect irradiated beef cut, ground beef, and Tteokgalbi during freezing storage. Gamma-irradiation significantly increased the DNA damage in frozen beef cut and ground beef samples. Among those, DNA nuclei of samples irradiated with absorbed doses of 1kGy or more showed typical comet-shaped damage, convincing that the samples were irradiated. Meanwhile, DNA nuclei in non-irradiated beef cut and ground beef samples were also damaged according to storage time. In particular, since the damage of DNA nuclei in the non-irradiated samples frozen for three months was similar to that of samples irradiated with a dose of 0.5 kGy, it was considered difficult to detect whether these samples were irradiated by Comet assay analysis. Likewise, gamma-irradiation of Tteokgalbi increased DNA damage. However, significant damage to DNA nuclei was observed even in the non-irradiated samples. Therefore, the application of the analysis method to determine whether the Tteokgalbi sample was irradiated was not appropriate. In conclusion, these results suggest that Comet assay could be limitedly applied only to fresh meat with a short storage period and minimal processing.

Packing effects on the intracavitary radiation therapy of the utaine lervix cancer ($^{192}Ir$source를 이용할 자궁경부암 강내치료시 사용하는 packing의 효과에 대한 고찰)

  • Cho, Jung-Kun;Lee, Du-Hyun;Si, Chang-Kun;Choi, Yoon-Kyung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • Purpose of the radio-therapy is maximize the radiation dose to the tumor while minimizing the dose to the critical organ. Carcinoma of the uterine cervix treatment are external irradiation or an interstitial brachtheraphy make use of isotope. Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. Authors make use of the patients data which 192Ir gives medical treatment intrcavity. Intracavitary radiation of the uterine cervix cancer, critical organ take $20\%$ below than exposure dose of A point in the ICRU report. None the less of the advice, Radiation proctitis and radiation cystitis are frequent and problematic early complications in patients treated with radiation for the uterine cervix cancer. In brachytherapy of uterine cervical cancer using a high dose rate remote afterloading system, it is of prime importance to deliver a accurate dose in each fractionated treatment by minimizing the difference between the pre-treatment planned and post-treatment calculated doses. Use of packing to reduce late complications intracavitary radiation of the uterine cervix cancer. Bladder and rectum changes exposure dose rate by radiotherphy make use of packing.

  • PDF

The Effect of Ginkgo Biloba Extract on Hypoxic Fraction of C3H Mouse Fibrosarcoma (Ginkgo Biloba Extract가 C3H 마우스 섬유육종의 저산소세포 분획에 미치는 영향)

  • Cho Chul Koo;Yi Chun Ja;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.205-214
    • /
    • 1995
  • Purpose : To investigate the effect of Ginkgo biloba extract (GBE) on hypoxic cell fraction and metabolic status in fibrosarcoma (FSa II) of C3H mouse. Materials and Methods : Fibrosarcoma (FSa II) 6 mm in diameter, growing in the right hindleg muscle of C3H mouse was used for estimation of hypoxic cell fraction using comparison of $TCD_{50}$. Radiation was given one hour after administration of GBE (100 mg/kg. i.p.) with or without priming dose of GBE (100 mg/kg, i.p.) given 24 hours earlier. Radiation was also given under air breathing condition or clamp hypoxia without GBE as controls. $^{31}p$ NMR spectroscopy was performed before and one hour after administration of GBE with or without priming dose of GBE. Results : $TCD_{50/120's}$ were 81.7 (77.7-86.0) Gy when irradiated under clamped hypoxia 69.6 (66.8-72.5) Gy under air breathing condition. 67.5 (64.1-71.1) Gy with a single dose of GBE (100 mg/kg) given one hour before irradiation, and 62.2 (59.1-65.5) Gy with two doses of GBE given at 25 hours and one hour before irradiation. The hypoxic cell fractions, estimated from $TCD_{50/120's}$, were $10.6{\%}$ under air breathing condition, $7.2{\%}$ after a single dose of GBE, and $2.7{\%}$ after two doses of GBE. The results of $^{31}P$ NMR spectroscopy were as follow. PCr/Pi ratio was $0.27{\pm}0.04$ and $0.40{\pm}0.04$ before and one hour after a single dose of GBE (p<0.05), respectively, without priming dose and $0.30{\pm}0.02$ and $0.71{\pm}0.04$, respectively, with priming dose (p<0.01). These findings indicate that the metabolic status is slightly improved after a single dose and markedly after repeated administrations. Conclusion : GBE decreases the hypoxic cell fraction and imprvoes the meta bolic status of tumor, probably by increasing the blood flow and delivery of oxygen and nutrients, resulting in increased radiosensitivity of tumor.

  • PDF

Evaluation of dose variation at the vertex during Total Skin Electron Beam (전신 피부 전자선 조사(TSEB)시 두정부(Vertex)에서의 선량 변화 평가)

  • Jeon Byeong-Chul;An Seung-Kwon;Lee Sang-Gyu;Kim Joo-Ho;Cho Kwang-Hwan;Cho Jung-Hee;Park Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.112-116
    • /
    • 2000
  • Purpose : The vertex scalp is always tangentially irradiated during total skin electron beam(TSEB) This study was discuss to the dose distribution at the vertex scalp and to evaluate the use of an electron reflector. positioned above the head as a means of improving the dose uniformity. Methods and Materials Vetex dosimetry was performed using ion-chamber and TLD. Measurements were 6 MeV electron beam obtained by placing an acrylic beam speller in the beam line. Studies were performed to investigate the effect of electron scattering on vertex dose when a lead reflector $40{\times}40cm$ in area, was positioned above the phantom. Results : The surface dose at the vertex, in the without of the reflector was found to be less than $37.8\%$ of the skin dose. Use of the lead reflector increased this value to $62.2\%$ for the 6 MeV beam. Conclusion : The vertex may be significantly under-dosed using standard techniques for total skin electron beam. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation.

  • PDF

Effects of low dose ${\gamma}$ radiation on the uptake of mineral nutrients in chinese cabbage and radish (저선량 ${\gamma}$ 선 조사가 배추와 무 종자의 발아와 양분흡수에 미치는 영향)

  • Yoon, Young-Man;Kim, Nam-Bum;Kim, Jae-Sung;Kim, Jeong-Gyu
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.344-348
    • /
    • 1999
  • To investigate hormetic effect of low dose ${\gamma}$-ray on the uptake of mineral nutrients in Chinese cabbage (Brassica campestris var. Hekjinju var. Surim and) and radish (Raphanus sativas var. Chung-un), seeds of these plants were irradiated with the dose of 1 to 10 Gy. Germination rate and dry weight were examined at pot experiment in greenhouse. Samples for analysis of mineral nutrient were harvested at 17 days and at 59 days after seedling and were analyzed by ICP. Brassica campestris varieties showed higher germination rate and dry weight production with increasing ${\gamma}$ ray dose. Dry weight of Hekjinju Surim and were 143% and 138% at 10Gy dose. respectively. There was no tendency in germination rate and dry weight production for Raphanus sativas var. Chung-un with ${\gamma}$-ray irradiation. The pattern of mineral nutrient content of these plants showed ${\gamma}$ or ${\delta}$ type of dose-reaction curve with no siginificant. This investigation suggests that the more results can be required to understand the hormetic effect of low dose ${\gamma}$ ray on the uptake of mineral nutrient for these plants.

  • PDF

Dosimetric comparison of IMRT versus 3DCRT for post-mastectomy chest wall irradiation

  • Rastogi, Kartick;Sharma, Shantanu;Gupta, Shivani;Agarwal, Nikesh;Bhaskar, Sandeep;Jain, Sandeep
    • Radiation Oncology Journal
    • /
    • v.36 no.1
    • /
    • pp.71-78
    • /
    • 2018
  • Purpose: To compare the dose distribution of three-dimensional conformal radiation therapy (3DCRT) with intensity-modulated radiation therapy (IMRT) for post-mastectomy radiotherapy (PMRT) to left chest wall. Materials and Methods: One hundred and seven patients were randomised for PMRT in 3DCRT group (n = 64) and IMRT group (n = 43). All patients received 50 Gy in 25 fractions. Planning target volume (PTV) parameters-$D_{near-max}$ ($D_2$), $D_{near-min}$ ($D_{98}$), $D_{mean}$, $V_{95}$, and $V_{107}$-homogeneity index (HI), and conformity index (CI) were compared. The mean doses of lung and heart, percentage volume of ipsilateral lung receiving 5 Gy ($V_5$), 20 Gy ($V_{20}$), and 55 Gy ($V_{55}$) and that of heart receiving 5 Gy ($V_5$), 25 Gy ($V_{25}$), and 45 Gy ($V_{45}$) were extracted from dose-volume histograms and compared. Results: PTV parameters were comparable between the two groups. CI was significantly improved with IMRT (1.127 vs. 1.254, p < 0.001) but HI was similar (0.094 vs. 0.096, p = 0.83) compared to 3DCRT. IMRT in comparison to 3DCRT significantly reduced the high-dose volumes of lung ($V_{20}$, 22.09% vs. 30.16%; $V_{55}$, 5.16% vs. 10.27%; p < 0.001) and heart ($V_{25}$, 4.59% vs. 9.19%; $V_{45}$, 1.85% vs. 7.09%; p < 0.001); mean dose of lung and heart (11.39 vs. 14.22 Gy and 4.57 vs. 8.96 Gy, respectively; p < 0.001) but not the low-dose volume ($V_5$ lung, 61.48% vs. 51.05%; $V_5$ heart, 31.02% vs. 23.27%; p < 0.001). Conclusions: For left sided breast cancer, IMRT significantly improves the conformity of plan and reduce the mean dose and high-dose volumes of ipsilateral lung and heart compared to 3DCRT, but 3DCRT is superior in terms of low-dose volume.

A Study on the Skin Dose Measurement of Glass Dosimeter Use During Rectal Cancer 3field Technic and Cervical Cancer 4field Technic Radiation Therapy (직장암 3문조사와 자궁경부암 4문조사 방사선 치료 시 유리선량계를 이용한 피부선량 측정에 관한 연구)

  • Shin, Seong-Soo;Choi, Won-Sik;Park, Cheol-Soo;Lee, Sun-Yeb;Cho, Jae-Hwan;Seo, Jeong-Min;Shim, Jae-Koo;Kim, Chan-Hyeong;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.157-163
    • /
    • 2011
  • Recently a variety of high technologies for radiation therapy (IMRT, SRS,. 3D-RT, etc.) has been developed. For the cervical and rectal cancer, 3field or 4field radiotherapy have been applied to the patients. In the case of two-dimensional treatment, one of the most typical side-effects is skin burn due to the radiation irradiation. In general the skin dose is evaluated by only a single measurement during the whole treatment period. In this study, however, skin dose was measured in each radiation treatment and the total skin dose was accumulated in a glass dosimeter through all the cases. After simulating the skin dose from treatment planning system, the results were compared with the actual skin doses. The results showed a good agreement between two data sets. Even though there are certain amount of errors caused by the patient movement along the treatment, the difference between actual dose and simulated dose was within the accepted range of error.