• Title/Summary/Keyword: Ionization coefficient

Search Result 119, Processing Time 0.027 seconds

Liquid Chromatography-tandem Mass Spectrometry for Quantification of Dioscin in Rat Plasma

  • Kong, Tae Yeon;Ji, Hye Young;Choi, Sang-Zin;Son, Miwon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.55-58
    • /
    • 2013
  • Dioscin is a biologically active steroidal saponin with anticancer and hepatoprotective effects. A rapid, selective, and sensitive liquid chromatographic method with electrospray ionization tandem mass spectrometry was developed for the quantification of dioscin in rat plasma. Dioscin was extracted from rat plasma using ethyl acetate at acidic pH. The analytes were separated on a Halo C18 column using gradient elution of acetonitrile and 0.1% formic acid and detected by tandem mass spectrometry in selected reaction monitoring mode. The standard curve was linear ($r^2$ = 0.998) over the concentration range of 1-100 ng/mL. The lower limit of quantification was 1.0 ng/mL using 50 ${\mu}L$ of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.3 to 8.0% and -5.4 to 10.0%, respectively. This method was applied successfully to the pharmacokinetic study of dioscin after oral administration of dioscin at a dose of 29.2 mg/kg in male Sprague-Dawley rats.

Simultaneous Determination of α-Amanitin and β-Amanitin in Mouse Plasma Using Liquid Chromatography-High Resolution Mass Spectrometry

  • Bang, Young Yoon;Lee, Min Seo;Lim, Chang Ho;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.12 no.3
    • /
    • pp.112-117
    • /
    • 2021
  • α-Amanitin and β-amanitin are highly toxic bicyclic octapeptides responsible for the poisoning of poisonous mushrooms such as Amanita, Galerina, and Lepiota by inhibiting RNA polymerase II, DNA transcription, and protein synthesis. A sensitive, simple, and selective liquid chromatography-high resolution mass spectrometric method using parallel reaction monitoring mode was developed and validated for the simultaneous determination of α- and β-amanitin in mouse plasma to evaluate the toxicokinetics of α- and β-amanitin in mice. Protein precipitation of 5 μL mouse plasma sample with methanol as sample clean-up procedure and use of negative electrospray ionization resulted in better sensitivity and less matrix effect. The calibration curves for α- and β-amanitin in mouse plasma were linear over the range of 0.5-500 ng/mL. The intra- and inter-day coefficient of variations and accuracies for α- and β-amanitin at four quality control concentrations were 3.1-14.6% and 92.5-115.0%, respectively. The present method was successfully applied to the toxicokinetic study of α- and β-amanitin after an oral administration of α- and β-amanitin at 1.5 mg/kg dose to male ICR mice.

Charge-Transfer Complex Formation between Stilbenes and 7,7,8,8-Tetracyanoquinodimethane

  • Jin, Jung-Il;Kim, Joon-Seop;Kim, Jeong-Deuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.9 no.3
    • /
    • pp.167-171
    • /
    • 1988
  • Formation of intermolecular charge-transfer complexes between 7,7,8,8-tetracyanoquinodimethane (TCNQ) and two different series of stilbene derivatives has been studied spectroscopically at $25^{\circ}$C in 1,2-dichloroethane. The compounds of Series I include stilbene and derivatives which have fused phenyl rings on one end of the central ethylene structure and a phenyl ring on the other end. The other Series, II, is comprised of stilbenes which have various para substituents on one of the two phenyl rings. The equilibrium constant, $K_c^{AD}$ and the molar extinction coefficient, ${\varepsilon}_{\lambda}^{AD}$, were determined using the Scott equation. The values of the charge-transfer transition frequency, ${\vu}_AD$ and $K_c{AD}$ correlated well respectively with the ionization potentials of the fused rings of Series Ⅰ or of the compounds of Series II and with the values of ${\sigma}_p$, the Hammett constants of the Series II substituents. trans-4-N,N-Dimethylaminostilbene and trans-4-nitrostilbene were found to be able to participate in electron transfer reaction with TCNQ forming the corresponding anion radical, TCNQ$^-$:

Quantification of Fargesin in Mouse Plasma Using Liquid Chromatography-High Resolution Mass Spectrometry: Application to Pharmacokinetics of Fargesin in Mice

  • Lee, Min Seo;Lim, Chang Ho;Bang, Young Yoon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.13 no.1
    • /
    • pp.20-25
    • /
    • 2022
  • Fargesin, a tetrahydrofurofuranoid lignan isolated from Flos Magnoliae, shows anti-inflammatory, anti-oxidative, anti-allergic, and anti-hypertensive activities. To evaluate the pharmacokinetics of fargesin in mice, a sensitive, simple, and selective liquid chromatography-high resolution mass spectrometric method using electrospray ionization and parallel reaction monitoring mode was developed and validated for the quantification of fargesin in mouse plasma. Protein precipitation of 6 µL mouse plasma with methanol was used as sample clean-up procedure. The standard curve was linear over the range of 0.2-500 ng/mL in mouse plasma with the lower limit of quantification level at 0.2 ng/mL. The intra- and inter-day coefficient variations and accuracies for fargesin at four quality control concentrations including were 3.6-11.3% and 90.0-106.6%, respectively. Intravenously injected fargesin disappeared rapidly from the plasma with high clearance values (53.2-55.5 mL/min/kg) at 1, 2, and 4 mg/kg doses. Absolute bioavailability of fargesin was 4.1-9.6% after oral administration of fargesin at doses of 1, 2, and 4 mg/kg to mice.

Study of Composite channel Structure of Metamorphic HEMT for the Improved Device Characteristics (기존의 MHEMT와 InP 합성 채널 MHEMT의 소자의 항복 특성 분석 및 비교 연구)

  • Choi, Seok-Gyu;Baek, Yong-Hyun;Han, Min;Bang, Seok-Ho;Yoon, Jin-Seob;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.12
    • /
    • pp.1-6
    • /
    • 2007
  • In this study, we have performed the channel modification of the conventional MHEMT (metamorphic high electron mobility transistor) to improve the breakdown characteristics. The Modified channel consists of the InxGal-xAs channel and the InP sub channel instead of the InxGa1-xAs channel. Since InP has the lower impact ionization coefficient in comparison with In0.53Ga0.47As, we have adopted the InP-composite channel in the modified MHEMT. We have investigated the breakdown mechanism and the RF characteristics for the conventional and the InP- composite channel MHEMTs. From the measurement results, we have obtained the enhanced on and off-state breakdown voltages of 2.4 and 5.7 V, respectively. Also, the increased RF characteristics have brought about the decreased output conductance for the InP-composite channel MHEMT. The cut-off frequency (fT) and the maximum oscillation frequency (fmax) for the InP-composite Channel MHEMT were 160 GHz and 230 GHz, respectively. It has been shown that the InP-composite channel MHEMT has the potential applications for the millimeter wave power device.

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • A rapid, sensitive analytical method for glucuronolactone in beverages was developed and validated using hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HILIC-ESI-MS/MS). To determine the optimum analytical conditions for glucuronolactone, three different kinds of HILIC columns and two mobile phases with different pH values were examined. An amide-bonded stationary phase with a pH 9 acetonitrile-rich mobile phase was the best condition in terms of column retention, ESI-MS/MS response area, and signal-to-noise ratio. After extraction, glucuronolactone was separated through the HILIC amide column and detected by negative ESI-MS/MS in selected reaction monitoring (SRM) mode. Nine energy drinks sold in Korea were spiked with glucuronolactone at a concentration of 5 ng/mL; the Monster $Energy^{TM}$ sample showed the smallest peak area and its signal-to-noise ratio was used for method validation. Good linearity was obtained in the concentration range from 20 to 1500 ng/mL with a correlation coefficient > 0.998. The developed method had a limit of detection (LOD) of 6 ng/mL and a limit of quantitation (LOQ) of 20 ng/mL. The recovery of this method at concentration of 20, 100, 500, and 1000 ng/mL was 96.3%-99.2% with relative standard deviations (RSD) of 1.6%-14.0%. A reproducibility precision assessment at concentration of 100 and 500 ng/mL was carried out among three laboratories. The recovery of that evaluation was 95.1%-102.3% with RSD of 2.7%-7.0%. An analysis of variance indicated that there was no difference between the recovery results of the three laboratories at the 5% significance level. The validated method is applicable to inspecting beverages adulterated with glucuronolactone in Korea.

Improvement of Analysis Methods for Fatty Acids in Infant Formula by Gas Chromatography Flame-Ionization Detector (GC-FID를 이용한 조제유류 중 지방산 분석법 개선 연구)

  • Hwang, Keum Hee;Choi, Won Hee;Hu, Soo Jung;Lee, Hye young;Hwang, Kyung Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • The purpose of this research is to improve analysis methods of determining the contents of fatty acids in infant formulas and follow-up formulas. A gas chromatography (GC) method was performed on a GC system coupled to flame ionization detector, with a fused silica capillary column (SP2560, 100 m×0.25 mm, 0.20 ㎛). The method was validated using standard reference material (SRM, NIST 1849a). Performance parameters for method validation such as specificity, linearity, limits of detection (LOD) and quantification (LOQ), accuracy and precision were examined. The linearity of standard solution with correlation coefficient was higher than 0.999 in the range of 0.1-5 mg/mL. The LOD and LOQ were 0.01-0.06 mg/mL and 0.03-0.2 mg/mL, respectively. The recovery using standard reference material was confirmed and the precision was found to be between 0.8% and 2.9% relative standard deviation (RSD). Optimized methods were applied in sample analysis to verify the reliability. All the tested products had acceptable contents of fatty acids compared with component specification for nutrition labeling. The result of this research will provide efficient experimental information and strengthen the management of nutrients in infant formula and follow-up formula.

Dose Distribution Study for Quantitative Evaluation when using Radioisotope (99mTc, 18F) Sources (방사성 동위원소 (99mTc, 18F) 선원 사용 시 인체 내부피폭의 정량적 평가를 위한 선량분포 연구)

  • Ji, Young-Sik;Lee, Dong-Yeon;Yang, Hyun-Gyung
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.603-609
    • /
    • 2022
  • The dose distribution in the human body was evaluated and analyzed through dosimetry data using water phantom, ionization chamber and simulated by Monte Carlo simulation for 99mTc and 18F sources, which are frequently used in the nuclear medicine in this study. As a result of this study, it was found that the dose decreased exponentially as the distance from the radioisotope increased, and it particularly showed a tendency to decrease sharply when the radioisotope was separated by 5 cm. It means that a large amount of dose is delivered to an organ located within 4 cm of source's movement path when a source uptake in the human body. Numerically, it was formed in the rage of 0.16 to 2.16 pC/min for 99mTc and 0.49 to 9.29 pC/min for 18F. In addition, the energy transfer coefficient calculated using the result was found to be similar to the measured value and the simulation value in the range of 0.240 to 0.260. Especially, when the measured data and the simulation value were compared, there was a difference is within 2%, so the reliability of the data was secured. In this study, the distribution of radiation generated from a source was calculated to quantitatively evaluate the internal dose by radioisotopes. It presented reliable results through comparative analysis of the measurement value and simulation value. Above all, it has a great significance to the point that it was presented by directly measuring the distribution of radiation in the human body.

Pretreatment method of urinary thiodiglycolic acid as metabolite of vinyl chloride (염화비닐의 요중 대사물질인 thiodiglycolic acid의 분석을 위한 전처리 조건)

  • Hong, Joo Youn;Kim, Chi Nyon;Jung, Jae Hoon;Chang, Jung Hwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.23-40
    • /
    • 1999
  • The analysis of thiodiglycolic acid in urine has been used as an index of biological exposure to vinyl chloride. Unfortunately thiodiglycolic acid has a strong hydrophilic character, because it has two carboxylic groups, so that it can only be extracted with organic solvent with a great difficulty. Underivatized thiodiglycolic acid tends to tail because of non-specific interaction with the inert support. Therefore, esterification is the obvious first choice for derivatization of thiodiglycolic acid, particularly for gas chromatography. In this study, the focus of interest is to compare two method of esterifications (methylation and silylation). Methylation is to make the methyl ester of thiodiglycolic acid by reaction with diazomethane. Silylation is to make the trimethylsilyl ester of thiodiglycolic acid by reaction with N-trimethylsily-ldiethylamine. The results and conclusions are as the following: 1. The detection limit (sensitivity) of methylated thiodiglycolic acid was $5.00{\mu}g/m{\ell}$ and silylated thiodiglycolic acid was $3.07{\mu}g/m{\ell}$ by gas chromatography with flame ionization detector. 2. The optimal liquid-liquid extraction of thiodiglycolic acid was as following: To each of the tubes, $15m{\ell}$ of urine, concentrated sulfuric acid (pH 1 - 2) and 5 gsodium sulfate were added. The samples was extracted three times with $5m{\ell}$ ethylacetate each time. 3. The methylated thiodiglycolic acid was more stable than silylated thiodiglycolic acid in extractional solvent which contained humidity. 4. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.07324 in methylated thiodiglycolic acid with external standard calibration, and 0.07033 in methylated thiodiglycolic acid with internal standard calibration. 5. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.10914 in silylated thiodiglycolic acid with external standard calibration, and 0.13602 in silylated thiodiglycolic acid with internal standard calibration. From the above results, the analysis of methylated thiodiglycolic acid was more sensitive (limit of detection) than silylated thiodiglycolic acid by gas chromatography. However, the methylated thiodiglycolic acid was stable in the humidity and was separated sharply on chromatogram. Also, analysis of methylated thiodiglycolic acid was more precise (pooled coefficient of variation for 4 days) than silylated thiodiglycolic acid. In conclusion, it is established that the analysis of methylated thiodiglycolic acid is appropriate for biological monitoring of exposure to vinyl chloride.

  • PDF

Determination of perchlorate in the Gum-River surface water by LC-ESI-MS/MS (금강 지표수에서 LC-ESI-MS/MS에 의한 염소산이온의 극미량 분석)

  • Lee, Young Joon;Lee, Jun Bae;Hong, Seon Haw;Kim, Hyun-Ji;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.435-440
    • /
    • 2012
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining perchlorate in the Gum-River surface water. Sample was directly injected into LC-ESI-MS/MS after the filtrations using PTFE filter paper. The coefficient of variation of perchlorate was less than 3% and the limit of quantification was 0.17 ${\mu}g/L$. Water samples were collected from thirty-five basins of Gum-River on February, April and June 2012, respectively. As a result, perchlorate was detected in the concentration range of 0.23-3.73 ${\mu}g/L$ (mean 0.20 ${\mu}g/L$) in the frequency of 15% in general surface water and in the concentration range of 0.36-25.10 ${\mu}g/L$ (mean 1.69 ${\mu}g/L$) in the frequency of 36% in surface water samples near industry area.