• 제목/요약/키워드: Ion-Selective Electrode

Search Result 184, Processing Time 0.022 seconds

Polymeric Membrane Cesium-Selective Electrodes Based on Quadruply-bridged Calix[6]arenes

  • Choe, Eun Mi;O, Hye Jin;Go, Seung Hwa;Choe, Yong Guk;Nam, Gye Chun;Jeon, Seung Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.12
    • /
    • pp.1345-1349
    • /
    • 2001
  • New quadruply-bridged calix[6]arenes (I-V) have been studied as cesium selective ionophores in poly(vinyl chloride) (PVC) membrane electrodes. PVC membranes were prepared with dioctyl sebacate (DOS) or 2-nitrophenyl octyl ether (o-NPOE) as the sol vent mediator and potassium tetrakis(p-chlorophenyl)borate as the lipophilic salt additive. These ionophores produced electrodes with near-Nernstian slope. The selectivity coefficients for cesium ion with respect to alkali, alkaline earth and ammonium ions have been determined. The lowest detection limit (logaCs+ = -6.3) and the higher selectivity coefficient (logkpotCs+,Rb+ = -2.1 by SSM, -2.3 by FIM for calix[6]arene I) for Cs+ have been obtained for membranes containing quadruply-bridged calix[6]arenes (I, Ⅱ, Ⅲ), which have no para t-butyl substituents on the bridging benzene ring.

A Study on the Saturation of Grain Size in Pb(Zr, Ti)$O_3$ Thin Films (Pb(Zr, Ti)$O_3$ 박막에서 결정립 크기 포화 현상에 관한 연구)

  • 이장식;김찬수;주승기
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.6
    • /
    • pp.530-536
    • /
    • 2000
  • During the grain growth of the PZT thin films by selective nucleation method using PZT seed, it was found that the grain size was saturated with the annealing temperature. The saturation of grain size was analyzed by the interfacial energy which appeared during the crystallization. The factors affecting the saturation of grain size were found to be the interfacial energy between perovskite phase and pyrochlore phase, and PZT thin film and the bottom Pt electrode. When the ion damage was introduced to the grain-size saturated PZT thin films, further lateral growth was observed. Pt bottom electrode thickness was changed to control the interfacial energy between the PZT thin film and the Pt bottom electrode. When Pt thickness was increased, the grain size was also increased, because the lattice parameter of Pt films was increased with the thickness of the Pt films. The incubation time of nucleation was increased with the amount of the ion damage on the Pt films.

  • PDF

Development of a Fluoride-Selective Electrode based on Scandium(III) Octaethylporphyrin in a Plasticized Polymeric Membrane

  • Kang, Young-Jea;Lutz, Christopher;Hong, Sung-A;Sung, Da-Yeon;Lee, Jae-Seon;Shin, Jae-Ho;Nam, Hak-Hyun;Cha, Geun-Sig;Meyerhoff, Mark E.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1601-1608
    • /
    • 2010
  • A scandium(III) porphyrin-based fluoride-selective potentiometric sensor and its application in the analysis of hydrofluoric acid is described. Scandium(III) octaethylporphyrin, an ionophore recently developed for the optical fluoride sensor, was employed as a host molecule for the selective binding with fluoride in the plasticized PVC membrane. Nernstian response for $F^-$ between $10^{-4.6}$ to $10^{-1}$ M was observed at a glycine-phosphate buffer (pH 3.0). The selectivity pattern was observed as $F^-$, salicylate $\gg$ $SCN^-$ > $Cl^-$, $Br^-$, $NO_3{^-}$, $ClO_4{^-}$, which is consistent with the binding constant data measured in the plasticized PVC membrane based on a sandwich membrane method. This highly selective and reversible fluoride-sensitive electrode was employed for the analysis of hydrofluoric acid (HF). A disposable differential-type HF sensor was fabricated on the screen-printed electrode and demonstrated its ability to detect the neutral HF in the acidic solution.

Perchlorate Ion-Selective PVC Membrane Electrode Based on the Quaternary Ammonium Salts (제4급 암모늄염을 이용한 과염소산 이온선택성 PVC막 전극)

  • 안형환;김용렬;강현춘;이한섭;이병철;강안수
    • Membrane Journal
    • /
    • v.3 no.3
    • /
    • pp.126-135
    • /
    • 1993
  • Perchlorate ion-selective PVC membrane electrode responsive to $10^{-6}M$ was developed by incorporating the ion-pair complex of perchlorate with the quaternary ammonium salts as a active material. The effect of chemical structure, the content of active material, the kinds of plasticizers, and the membrane thickness on the electrode characteristics such as the linear response range and Nernstian slope of the electrode were studied. With the results, the useful pH range and the selectivity coefficients to various interfering anions were compared and investigated. It was obtained that the effect of the chemical structure of an active material on the electrode characteristics was improved with increasing the alkyl chain length of the quarternary ammonium salts in the ascending order of Aliquat 336P, TOAP, TDAP, and TDDAP. The electrode characteristics was improved with the decrease of the active material content below the optimum membrane composition, and DBP was the best as a plasticizer. The optimum membrane composition was 9.09wt% of TDDAP, 30.3wt% of PVC, and 60.6wt% of ptasticizer(DBP). And the optimum membrane thickness was0.45mm at this composition. Under the above condition, thelinear response ranger was $10^{-1}~1.2 {\times} 10^{-6}M$, and the detection limit was $5.1{\times}10^{-7}M$ with the Nernstian slope of 57mV/decade of activity of perchlorate ion. The electrode potential was stable within the pH range from 4 to 11. The selectivity coefficient was as shown below : $SCN^->I^->NO_3^->Br^->ClO_3^->F^->Cl^->SO_4^{2-}$

  • PDF

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (III). Continuous-Automated Determination of Nitrite Ion Using a New Tubular PVC Membrane Type of Selective Electrode Nitrate (溶解氣體 分析用 氣體感應膜 이온選擇性 電極 (第 3 報). 새로운 管形 PVC膜 질산이온 選擇性 電極을 이용한 아질산이온의連續·自動化 定量)

  • Lee Heung Lark;Yun Jong-Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.51-58
    • /
    • 1991
  • A new tubular poly(vinyl chloride) membrane type of nitrate selective electrode was prepared and its characteristics were evaluated. The response slope, detection limit, and response time (t$_{99}$) under the optimum membrane composition (5${\%}$ aliquat-NO$_3$ solution + 32${\%}$ poly(vinyl chloride) + 63${\%}$ dibutyl sebecate) of the electrode were 58.5 ${\pm}$ 0.1 mV/decade, 2.0 ${\times}$ 10$^{-5}$ M, and 25 seconds, respectively. The nitrite ion was determined by the continuous-automated method using the new electrode. 10$^{-2}$ M phosphate buffer solution (pH 7.6) was used as a recipient solution. And also hydrogen peroxide (0.3${\%}$) was added to the recipient as an oxidant. The linear response range and response range and response slope for the standard nitrite solution under the optimum condition of this electrode system were 8.0 ${\times}$ 10$^{-5}$ M ∼ 5.0 ${\times}$ 10$^{-2}$ M and 56.8 ${\pm}$ 0.2 mV/decade, respectively.

  • PDF

Potential of Perchlorate Ion-Selective Electrode in PVC Membrane and Electrode Characteristics by ac Impedance (과염소산 이온선택성 PVC막 전극전위와 임피던스에 의한 전극특성)

  • 김경민;조경섭;강안수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.49-52
    • /
    • 1998
  • 1. 서론 : 화약이나 고체 충진제, 고체로\ulcorner 추진제의 산화제, slurry blasting agent 및 동물사료의 식품첨가제로 사용되고 있는 과염소산은 발화나 폭발성이 매우 강한 산화제로 정확한 순도를 측정하는 것은 중요하다. 용량분석법과 중량분석법에 비교하여 조작이 간단하고 편리한 과염소산이온의 농도를 직접 측정할 수 있는 PVC막 전극에 대한 많은 연구가 진행되고 있다. (생략)

  • PDF

Tetrahydrofuran-Containing Crown Ethers as Ionophores for NH+4-Selective Electrodes

  • Jin, Hua-Yan;Kim, Tae-Ho;Kim, Jin-Eun;Lee, Shim-Sung;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.59-62
    • /
    • 2004
  • The ammonium ion-selective electrodes ($NH^+_4$-ISEs) based on the tetrahydrofuran(THF)-containing-16-crown-4 derivatives,1,4,6,9,11,14,16,19-tetraoxocycloeicosane ($L^1$) and 5,10,15,20,-tetramethyl-1,4,6,9,11,14,16,19-tetraoxocycloeicosane ($L^2$), were prepared and the electrode characteristics were tested. The conditioned $NH_4^+$-ISEs (E1) based on $L^1$ with TEHP as a plasticising solvent mediator gave best results with near-Nernstian slope of 53.9 mV/decade of activity, detection limit of $10^{-4.9}$ M, and enhanced selectivity coefficients for the $NH^+_4$ ion with respect to an interfering $K^+$ ion (log $K^{pot}_{NH_4^+,K^+}$ = -1.84). This result was compared to other ammonium ionophores reported previously, for example, that of nonactin (log $K^{pot}_{NH_4^+,K^+}$ = -0.92). The proposed electrode showed no significant potential changes in the range of 3.0 < pH < 9.0.

Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects

  • Seo, Hyung-Ran;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1484-1488
    • /
    • 2004
  • The thiocyanate-selective PVC membrane electrodes based on 5,10,15,20-tetrakis(2,4,6-trimethylphenyl)-porphyrinatomanganese(III) chloride [Mn(TMP)Cl] and 5,10,15,20-tetrakis(2,6-dichlorophenyl)porphyrinatomanganese(III) chloride $[Mn(Cl_8TPP)Cl]$ as ion carriers were investigated. The effect of ionophores, membrane compositions, plasticizers, and solution pHs on the response characteristics were studied. The Mn(TMP)Cl as an ionophore shows the best potentiometric sensitivity with a slope of -58.7 mV/decade and a detection limit of $log[SCN^-]$ = -6.90, and selectivity for thiocyanate over strong hydrophobic interfering anions such as ${ClO_4}^-$ and salicylate. The potentiometric response is affected by the electronic effect of the substituents and solution pHs. The presence of substituents with electron donating and more liphophilic characters around the ligated metal center produces an improved response toward $SCN^-$.