• 제목/요약/키워드: Ion-Chromatography Science Technology

검색결과 323건 처리시간 0.027초

Suppressed 이온 크로마토그래피에서 과량의 양이온이 낮은 농도의 음이온 분석에 미치는 영향 (The Effect of High Concentration Cation Matrix on the Analysis of the Low Anion Concentration in Suppressed Ion Chromatography)

  • 강미정;이석근
    • 분석과학
    • /
    • 제11권6호
    • /
    • pp.495-498
    • /
    • 1998
  • The effect of high concentration ion matrix on the analysis of low anion concentration in the suppressed ion chromatography was studied. The anions studied were $Br^-$, $NO_3{^-}$, $HPO_4^{2-}$, $SO_4^{2-}$, and $C_2O_4^{2-}$ in the presence of excess NaCl and $CaCl_2$. In this study we suggested that the erroneous results in the suppressed ion chromatographic determination of small concentration of anions were not caused by the interaction of large amount of cation in the suppressor, but by the interaction of cation with concerned anion in the original solution. The error in the analysis of such anion can not be eliminated just by dilution. Therefore, we suggested that standard addition method might be adequate for analyses of those samples.

  • PDF

Comparison of the Exopeptidase Activity of Fractions from Crude Extracts of Octopus Octopus vulgaris Cuvier Hepatopancreas Using Different Fractionation Methods

  • Kim, Min Ji;Kim, Hyeon Jeong;Kim, Ki Hyun;Heu, Min Soo;Kim, Jin-Soo
    • Fisheries and Aquatic Sciences
    • /
    • 제17권2호
    • /
    • pp.181-187
    • /
    • 2014
  • This study was performed to identify the optimum fractionation method and conditions to obtain exopeptidase-active fractions from octopus hepatopancreas (HP) crude extracts (CEs) using four techniques: solid ammonium sulfate fractionation, polyethylene glycol (PEG) fractionation, anion exchange chromatography, and gel filtration chromatography. The fractions with the highest total activity toward L-leucine-p-nitroanilide (Leu-pNA) were fraction IV from the ammonium sulfate and PEG fractionation, and fraction II in ion exchange and gel filtration chromatography. The total exoprotease activity of these fractions was highest in fraction IV (4,050.20 U) of ammonium sulfate fractionation, followed by fraction II (3,600.28 U) from gel filtration chromatography, fraction IV (2,861.30 U) from PEG fractionation, and fraction II (2,576.28 U) from ion exchange chromatography. These results suggest that ammonium sulfate fractionation using 60-80% ammonium sulfate was the most efficient method for separating the exoprotease active fractions from CEs of octopus HP.

Ion chromatography에 의(依)한 나뭇잎의 저분자량(低分子量) 유기산(有機酸) 분석(分析) (Determination of Low Molecular Weight Organic Acids in Pacific Silver Fir Leachates by Using Ion Chromatography)

  • 최인규
    • Journal of the Korean Wood Science and Technology
    • /
    • 제21권3호
    • /
    • pp.22-29
    • /
    • 1993
  • 나뭇잎으로부터 발생되는 저분자량 유기산을 이온크로마토그래피를 이용하여 분석하였다. 이 방법은 자연상태의 나뭇잎 (needle litter)을 유기용매의 추출 없이 그대로 이용할 수 있어서 사용하기에 편리하다. 본 논문에서는 이온 크로마토그래피의 사용방법과 침엽수잎(Pacific Silver Fir)의 부후정도에 따른 유기산의 종류와 농도의 변이를 간략하게 소개한다. 초기의 침엽수잎 여과액으로부터는 $C_2$에서 $C_4$까지의 아세트산(acetic acid), 프로피온산(propionic acid), 옥살산(oxalic acid) 그리고 포름산(formic acid) 등이 주종을 이루지만 부후정도가 커짐에 따라 방향핵을 가진 방향핵 유기산(aromatic organic acid)이 발생한다.

  • PDF

Rapid Analytical Method of Nitrite and Nitrate in Fish by Ion Chromatography

  • Oh, Myung-Cheol;Oh, Chang-Kyung;Kim, Soo-Hyun
    • Preventive Nutrition and Food Science
    • /
    • 제1권1호
    • /
    • pp.1-5
    • /
    • 1996
  • Rapid analytical method was investigated to determine precursors of N-nitrosamine such an nitrite and nitrate in squid(Illex illecebrosus and Sepiell maindroni), codfish(Gadus marcrocephalus)and flatfish(Paralichthys olivaceus) by ion chromatography(IC) and colorimetric methods. Recoveries of nitrite and nitrate in fish tissues were 89~98.7% and 94.1~99.8% for IC, and 98.4~103.7% and 67.7~102.2% for colori-metric method, respectively. Using IC, nitrite was not detected and nitrate was 0.89~1.23mg/kg, while using colorimetric method, nitrite and nitrate were NO~0.08mg/kg and 0.3~0.42mg/kg, respectively. Therefore, the IC method showed better recoveries, and was applicable to extract nitrite and nitrate simultaneously, and is simpler compared with colorimetric method in analyzing nitrite and nitrate from fish tissues.

  • PDF

이온 크로마토그래피를 이용한 빗물과 분유, 우유중의 nitrite와 nitrate의 정량분석 (Quantitative Analysis of Nitrate and Nitrite in Rain, Milk and Infant Formula using Ion Chromatography)

  • 강미정;이석근
    • 분석과학
    • /
    • 제12권6호
    • /
    • pp.583-586
    • /
    • 1999
  • The quantitative analysis of nitrate and nitrite in rain, milk and infant formula was done by Ion Chromatography. The nitrite was not detected(<0.1 mg/L) in all the samples. However, the nitrate was detected in the range of 0.1~4.9 mg/L in rain, 9.8~19.8 mg/L in milk, and 80~300 mg/L in infant formula, respectively. Some content of nitrate is close to the maximum contaminant level(MCL) which is 10 mg/L as $NO_3-N$, 44.3 mg/L as $NO_3$.

  • PDF

이온 크로마토그래피용 모세관 컬럼의 개발 (Development of Capillary Columns for Ion Chromatography)

  • 김호현;표동진
    • 분석과학
    • /
    • 제12권6호
    • /
    • pp.521-527
    • /
    • 1999
  • 본 연구에서는 적은 양의 시료를 분석할 수 있는 이온 크로마토그래피용 모세관 컬럼을 개발하였다. 내경이 작은 모세관 컬럼을 사용하는 경우 이동상의 유속은 보통 $5{\sim}15{\mu}L/min$ 정도 되고 컬럼의 길이는 50~150 mm 정도이다. 컬럼은 RSL-300 fused silica 모세관(내경 : 0.53 mm, 외경 : 0.67 mm)과 AG14 column resin(support : polystyrene-divinylbenzene, functional group : aulkyl quatemary ammonium)을 이용하여 만들었다. 또한 이런 모세관 컬럼에 맞는 새로운 전도도 셀과 억제컬럼도 함께 개발하여 사용하였다. 이 모세관 컬럼을 이용하여 실제 음이온들(fluoride, nitrite, nitrate, chlorate)을 분석한 결과 재현성 있고 좋은 크로마토그램을 얻었다.

  • PDF

철제유물의 수용성 염소이온 측정방법에 대한 안정성 평가 (Stability Evaluation on Measuring Water-soluble Chloride Anions from Iron Artifacts)

  • 이재성;박형호;유재은
    • 보존과학회지
    • /
    • 제26권4호
    • /
    • pp.397-406
    • /
    • 2010
  • 철제유물에서 용출된 수용성 염소이온의 농도를 측정하는 가장 이상적인 방법은 탈염처리 용액을 이온크로마토그래피(Ion Chromatography)로 분석하는 것이지만 대부분의 문화재 관련기관에서는 예산이나 전문인력 부족 등의 이유로 사용하지 못하고 염소이온농도 측정기(Cl meter)를 주로 사용하고 있다. 본 연구는 철제유물의 탈염처리 용액에 대한 염소이온농도 측정기의 $Cl^-$ 이온 농도 측정결과와 이온크로마토그래피의 측정결과를 교차 검증하여 상호 기기간의 신뢰성과 안정성을 평가하고자 한다. 분석결과 초순수는 염소이온농도 측정기의 전극에 잔류하는 수용성 염소이온의 영향으로 미량의 염소이온이 검출되었고, Sodium sesquicarbonate 시약 성분에 미량으로 존재하는 수용성 염소이온이 검출되었다. 탈염처리한 수용액은 탈염 1차에서 가장 많은 염소이온이 측정되었으며, 탈염 2차부터 탈염 4차까지는 소폭 감소하다가 초순수을 이용하는 탈알칼리 단계에서부터 다시 감소하는 경향을 보였다. 염소이온농도 측정기마다 측정횟수에 따른 편차를 보였으며, 탈염용액 내에 염소이온 농도가 높을수록 편차는 심해졌다. 하지만 염소이온 농도가 낮을 경우 편차가 적어 철제유물의 염소이온농도를 측정하기 위한 측정기기로 안정된 결과를 보였다. 전기전도도 측정법은 알칼리 용액의 전기전도도가 높게 나타남에 따라 $Cl^-$ 이온의 함량을 예측하기에는 부적합한 것으로 판단된다.

Determination of Clotiazepam in the Plasma Using Gas Chromatography/Mass Spectrometry with an Ion-Trap Detector and its Application to Pharmacokinetics in Healthy Volunteers

  • Kwon, Oh-Seung;Kim, Seung-Yong;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제36권2호
    • /
    • pp.123-129
    • /
    • 2006
  • A method determining the plasma concentration of clotiazepam was developed by using gas chromatography/mass spectrometry with an ion-trap detector and was validated for applying pharmacokinetics to human volunteers orally taken 5 mg dose of clotiazepam. The detection limit was 1 ng/ml and the limit of quantitation was 5 ng/mt. Intraday reproducibility and accuracy bias % were less than 8.2 and 10.2% with inter-day variations for those being within 7.0 and 13.8%, respectively. The recovery of clotiazepam was higher than 87%. The principal pharmacokinetic parameters were determined from the plasma concentration-time plot by non-compartmental or two-compartmental analysis. In non-compartmental analysis, the elimination half-life of 10.4 hr and the area under the curve of 651.3 ng hr/ml were determined, and the maximal concentration (158.6 ng/ml) in the plasma was obtained at 0.56 hr post-dose. The developed method can be appropriate to apply pharmacokinetics and bioequivalence of clotiazepam.

연소IC를 이용한 플라스틱 중 할로겐 물질 정량 (Determination of halogen elements in plastics by using combustion ion chromatography)

  • 정재학;김효경;이양형;이임수;신종근;이상학
    • 분석과학
    • /
    • 제21권4호
    • /
    • pp.284-295
    • /
    • 2008
  • 플라스틱 시료 중 각종 유해물질 유무 확인을 위한 여러 가지 시험항목을 저비용으로 빠르게 분석할 수 있는 방법으로 Combustion ion chromatography(연소IC)를 사용한 방법을 채택하였다. F, Cl 및 Br의 3개 항목에 대하여 연소IC로 시험법 유효화 검증을 실시한 결과, 검량선은 0.5~4.0 mg/kg 농도범위에서 $r^2$ = 0.999~1.000의 상관관계 계수를 갖는 좋은 직선성을 나타내었으며, 검출한계는 0.005~0.024 mg/kg, 정량한계는 0.014~0.073 mg/kg 이였다. 인증표준물질(CRM)을 사용한 연소IC의 회수율은 95.5~104.9%이었다. 본 결과를 토대로 국내외 시험기관간 비교 숙련도 시험을 실시하였으며, 그 결과 연소IC 방법이 전기전자제품 중에 halogen-free 및 기타 유해물질 규제 대응을 위한 효율적인 분석방법임을 확인하였다.