• Title/Summary/Keyword: Ion exchanger

Search Result 159, Processing Time 0.026 seconds

Separation of $PuO_2^{2+}$, $Pu^{4+}$ and $Pu^{3+}$ by Ion Chromatography (이온크로마토그래피에 의한 $PuO_2^{2+}$, $Pu^{4+}$$Pu^{3+}$의 분리)

  • Joe, Kih Soo;Kim, Jong Gu;Park, Yang Soon;Kim, Do Yang;Eom, Tae Yoon
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.280-285
    • /
    • 1999
  • Separation of plutonium species was studied by ion chromatography installed in a glove box for the determination of plutonium element. The plutonium species, $PuO_2^{2+},\; PC^{4+}\; and\; Pu^{3+}$, were stably separated on dynamically equilibrated cation exchanger using 1-octanesulfonate and ${\alpha}$-HiBA eluant after controlling the plutonium oxidation states with KI, $NaNO_2\;or=;KBrO_3$ based on the oxidation-reduction potentials. For the separation of plutonium from other matrix, $PuO_2^{2+}\; and\; Pu^{4+}$ were reduced to $Pu^{3+}$ with KI and $NaNO_2$ followed by cation exchange chromatography.

  • PDF

The effect of UV-C irradiation and EDTA on the uptake of Co2+ by antimony oxide in the presence and absence of competing cations Ca2+ and Ni2+

  • Malinen, Leena;Repo, Eveliina;Harjula, Risto;Huittinen, Nina
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.627-636
    • /
    • 2022
  • In nuclear power plants and other nuclear facilities the removal of cobalt from radioactive liquid waste is needed to reduce the radioactivity concentration in effluents. In liquid wastes containing strong organic complexing agents such as EDTA cobalt removal can be problematic due to the high stability of the Co-EDTA complex. In this study, the removal of cobalt from NaNO3 solutions using antimony oxide (Sb2O3) synthesized from potassium hexahydroxoantimonate was investigated in the absence and presence of EDTA. The uptake studies on the ion exchange material were conducted both in the dark (absence of UV-light) and under UV-C irradiation. Ca2+ or Ni2+ were included in the experiments as competing cations to test the selectivity of the ion exchanger. Results show that UV-C irradiation noticeably enhances the cobalt sorption efficiency on the antimony oxide. It was shown that nickel decreased the sorption of cobalt to a higher extent than calcium. Finally, the sorption data collected for Co2+ on antimony oxide was modeled using six different isotherm models. The Sips model was found to be the most suitable model to describe the sorption process. The Dubinin-Radushkevich model was further used to calculate the adsorption energy, which was found to be 6.2 kJ mol-1.

Ion Exchange of Glutamic Acid Coupled with Crystallization (결정화 반응이 결합된 글루탐산의 이온교환)

  • 이기세
    • KSBB Journal
    • /
    • v.11 no.5
    • /
    • pp.606-612
    • /
    • 1996
  • A specific ammino auid in a mixture can be crystallized inside an ion exchange column when displacer concentration is high enough to concentrate the amino acid in a pure band beyond its solubility limit. Glutamic acid formpd a discrete crystal layer in a cation exchanger column by operating displacement development mode and using a high concentration of displacer NaOH. The glutamic acid crystal formed was eluded from the column with the effluent stream and collected in a fraction collector. When 1.0 M of NaOH was used as a displacer, more than 60% of the loaded glutamic acid was recovered as crystal. The continuous crystallization and dissolution of crystal occurred, resulting in apparent movement of the crystal along the column without clogging or pressure increase. NaOH was proved a better displacer than NaCl because hydroxide ions neutralized hydrogen ions released from the resin and thus reduced the number of hydrogen ion competing with sodium ion for re-adsorption. The displacement development process coupled with crystallization provided higher concentration and recovery of glutamic acrid than conventional chromatography.

  • PDF

Synthesis of High Affinity Anion Exchanger Using Ultrafine Fibrous PPmb Nonwoven Fabric by Co60 Irradiation Method (방사선 조사에 의한 초극세 폴리프로필렌 섬유부직포를 이용한 고효율 음이온교환체의 합성)

  • Choi, Kuk-Jong;Lee, Choul-Ho;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.32 no.6
    • /
    • pp.509-515
    • /
    • 2008
  • The aminated polypropylene melt blown ion exchange fibers were synthesized with acrylic acid monomer onto polypropylene melt blown fibers by radiation-induced polymerization and subsequent amination. Degree of grafting was increased with increasing the acrylic acid monomer concentration and total dose. The highest degree of grafting was obtained 140% at a monomer concentration of 20 v/v% acrylic acid and total dose of 4 kGy. Optimum condition of Mohr's salt was 5.0 $\times10^{-3}$ M. Degree of amination was increased with increasing degree of grafting. Water content was about 1.5 times higher than that of trunk polymer. The maximum ion-exchange capacity was 7.3 meq/g which was 2$\sim$3 times higher than a commercial ion exchange fiber. The average pore size was decreased and BET surface area was increased in order of PPmb, PPmb- g- AAc and APPmb- g- AAc. The average pore size and BET surface area of synthesised fibers were $366.1\;{\AA},\;3.71m^2/g,\;143.3\;{\AA},\;4.94m^2/g,\;40.97\;{\AA},\;8.98m^2/g$, respectively.

A study on breakthrough characteristics of ion exchange bed with H- and ETAH-form resins for cation exchange in NH3 and ETA solution including trace NaCl (미량의 NaCl을 포함하는 NH3 및 ETA 용액에서 H 및 ETAH 형 수지에 대한 이온교환 파과 특성 연구)

  • Ahn, Hyun-Kyoung;Kim, Youn-Su;Park, Byung-Gi;Rhee, In-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.533-544
    • /
    • 2021
  • Ion exchange (IX) performance on the exchanger bed is essentially evaluated for the generation of ultrapure water in electronics and chemical industries and for the corrosion control in nuclear power plants. The breakthrough characteristics of IX bed with multi-component were investigated with both cation- and mixed-IX beds of H- and ETAH-form for four kinds of cation exchange resins by using the combined solution of ethanolamine (ETA) and ammonia (NH3) at trace NaCl. Unlike major components (ETAH+ and NH4+ ), the phenomena of breakthrough and overshooting at bed outlet were not observed by Na+ over the test period (> 3 times theoretical exchange capacity of IX bed). The breakthrough from H-form resin bed was sequentially reached by ETAH+ and NH4+, while the overshooting was observed for ETAH+ at the breakthrough of NH4+. NH4+ was 51.5% higher than ETAH+ in terms of the relative selectivity determined with the width of breakthrough zone. At the increased concentration of Na+ at bed inlet, the selectivity and the overshooting were decreased and increased, respectively. Na+ leakage was higher from ETAH-form resin bed and was not identical for four kinds of cation-exchange resins, which may be reduced by improving the intrinsic property of IX resin.

Performance Test of PEMFC with Hollow Fiber Membrane (중공사막 가습에 따른 PEMFC의 성능 평가)

  • Lee, Ho-Yeol;Chon, Kwang-Wu;Park, Chang-Kwon;Oh, Byeong-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.1
    • /
    • pp.82-91
    • /
    • 2005
  • Polymer membrane needs to maintain appropriate moisture. Insufficient moisture causes low conduction of hydrogen ion because of increased contact resistance between electrode and membrane by shrinking membrane, and abundant moisture decreases fuel cell performance as difficulty of diffusion reacting gas. Therefore, water controlling system is very consequential for the polymer membrane fuel cell. If hollow fiber membrane humidification is used between fuel and air lines, it is possible to supply heat to fuel and air by using thermal exchanger. It can supply appropriate humidity depending on operating temperature, and can recover heat from exhaust gas which contains water vapor and air. Because of simple structure of humidification system, this system can be easily applied in the PEMFC and cut down cost.

A Case of Congenital Chloride Diarrhea in Premature Infant (Congenital Chloride Diarrhea 1례)

  • Yoon, Sung Kwan;Kim, Eun Young;Moon, Kyung Rye;Park, Sang Kee
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.3
    • /
    • pp.308-311
    • /
    • 2003
  • Congenital chloride diarrhea is a serious autosomal recessive disease, and defect of intestinal electrolyte absorption that involves, specifically, $Cl^-/{HCO_3}^-$ exchange in the distal part of the ileum and colon. The clinical feature is dominated by profuse, watery diarrhea containing high concentrations of chloride(>90 mmol/L) and sodium. The chloride loss results in severe dehydration with a hypochloremic alkalosis. The molecular pathology involves an epithelial $Cl^-/{HCO_3}^-$ exchanger protein. Mucosal ion transport is affected to differing degrees and the severity of the disease may thus vary. Recently, a gene defect on chromosome 7 has been identified. However, there was a deficit in replacement of fluid and electrolyte, abdominal distension remained and the character of stools was watery. We report a case of congenital chloride diarrhea in a premature female who presented with watery diarrhea containing high concentrations of chloride and abdominal distension.

New Analytical Method for Separation and Identification of Heavy Metals (I) (중금속의 분리 및 검출을 위한 분석화학적 연구 (제 1 보). 새로운 분리방법의 개발)

  • Kim, Youn-Doo;Bae, Jun-Heon;Shin, Young-Kook
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.231-235
    • /
    • 1987
  • In 10M chloride (4M HCl + 6M LiCl) solution, cobalt, but not nickel, formed complex anion (${CoCl_3}^-$), and this anion was extracted by a liquid anion exchanger with Amberlite LA-2. The ion exchange capacity was 2.175meq of cobalt complex per unit ml of Amberlite LA-2. Upon eluting the resin with 0.4M nitric acid, the cobalt complex was stripped and transfered into eluate quantitatively. By using this separation method in the chloride solution dissolved with 50mg of cobalt (II) and 500mg of nikel(II), recovery of cobalt were 99.6 percent.

  • PDF

Studies on Atomic Absorption Spectrophotometric Analysis of Chromium in Urine by Trioctylamine (Trioctylamine을 이용한 뇨중 크롬의 원자흡수 분광분석에 관한 연구)

  • Kim, Suk Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.214-220
    • /
    • 1991
  • As chromium in urine remains as oxychromic acid ions, chromium was extracted by using ion pair formed by anion exchanger trioctylamine. then after it is noted whether this TOA-MIBK method is effective or not for the chromium analysis by using flame method of Atomic absorption Spectrophotometric Analysis. The result is as following. 1. Effects of various acids on the extraction of Cr with MIBK including TOA are good in order $NHO_3$, $H_2SO_4$, HCl in distilled water sample and its proper concentration of HCl is 0.2 N. 2. For the analysis of urine sample, the best result can be achieved by following condition. After finished pretreatment adjusted to pH 6.5-7.5 by NaOH and again controlled pH 0.5-0.6 by HCl. 3. Though TOA concentration slightly affects the analytic value, best result is noted in 1-3% concentration. 4. Recovery rates of urine samples made by $0.3mg/l{\cdot}urine$, $0.6mg/l{\cdot}urine$, $0.9mg/l{\cdot}urine$ are shown from 96.7% to 104.8%. 5. Recovery rates of urine samples made by $0.01mg/l{\cdot}urine$, $10.03mg/{\cdot}urine$, $0.05mg/l{\cdot}urine$ are shown from 89.3% to 98.6%.

  • PDF

Wastewater Treatment Process Study for Used Diaper Recycling (사용 후 기저귀 재활용을 위한 폐수처리방안 연구)

  • Kim, Kyung Shin;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.2
    • /
    • pp.24-33
    • /
    • 2015
  • This study aims to suggest wastewater treatment options for diaper recycling by identifying characteristic analysis of wastewater from diaper recycling process and efficiency evaluation of wastewater treatment units. The wastewater characteristic analysis showed that the concentration of organic pollutants and ionic materials were very high comparing to seawater. Through the investigation of similar wastewater treatment, six treatment units were identified to reduce pollutants. It is found UF(ultra-filtration), DAF(dissolved air flotation), fenton oxidation, electro-coagulation and chemical-coagulation are effective in reducing organic pollutants while membrane system and ion exchanger are effective in reducing ionic materials. Even though the target of water quality should be secured in terms of managing organic pollutants level, the application of treatment unit for reducing ionic material needs lots of considerations. This result suggests that reuse of pulping wastewater after controlling organic pollutants is better than direct discharge of pulping wastewater. To select the appropriate wastewater treatment unit, an economic analysis about operation condition, wastewater flow, cost, efficiency should be considered.