• Title/Summary/Keyword: Ion current

Search Result 1,471, Processing Time 0.027 seconds

A Design and Control of Rapid Electric Vehicle Charging System for Lithium-Ion Battery (전기자동차용 리튬이온 배터리 급속충전장치 설계와 제어)

  • Kang, Taewon;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungik;Kim, Simon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.26-36
    • /
    • 2013
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charge mode, constant-current mode, and constant-voltage mode. The pre-charge mode employs the stair-case shaped current profile to accomplish shorter charging time while maintaining the reliable operation of the battery. The proposed system is specified to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 78A. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system.

Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line (초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석)

  • Lim, Jae-Seop;Shin, Koo-Yong;Lee, Dong-Il;Ju, Mun-No;Yang, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1638-1643
    • /
    • 2010
  • HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

Electro-Thermal Model Based-Temperature Estimation Method of Lithium-Ion Battery for Fuel-Cell and Battery Hybrid Railroad Propulsion System (하이브리드 철도차량 시스템의 전기-열 모델 기반 리튬이온 배터리 온도 추정 방안)

  • Park, Seongyun;Kim, Jaeyoung;Kim, Jonghoon;Ryu, Joonhyoung;Cho, Inho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.357-363
    • /
    • 2021
  • Eco-friendly hybrid railroad propulsion system with fuel-cell and battery was suggested to reduce carbon dioxide gas and replace retired diesel railroads. Lithium-ion battery with high energy/power density and long lifetime is selected as the energy source at the battery side due to its excellent performance. However, the performance of lithium-ion batteries was affected by temperature, current rate, and operating condition. Temperature is known to be the most influential factor in changing battery parameters. In addition, appropriate thermal management is required to ensure the safe and effective operation of lithium-ion battery. Electro-thermal coupled model with varying parameter depends on temperature, and state-of-charge (SOC) is suggested to estimate battery temperature. The electric-thermal coupled model contains diffusion current using parameter identification by adaptive control algorithm when considering thermal diffusion effect. An experiment under forced convection was conducted using cylindrical cell and 18 parallel-connected battery module to demonstrate the method.

FAST CHARGING STRATEGY FOR LITHIUM ION BATTERY

  • Hoang, Thi Quynh Chi;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.70-71
    • /
    • 2014
  • In this paper, an advanced charging strategy for improving the charging performance of the Li-ion polymer battery is proposed, which is based on the battery characteristic. Simulation results show that the proposed charging current pattern can improve the charging speed of battery in comparison with the standard CC-CV (constant current - constant voltage) charging strategy and the pulse-charging strategy.

  • PDF

Recent Developments in Characterization of Ion-Exchange Membrane Processes: Impedance Spectroscopy for a Concentration Polarized Boundary Layer

  • Park, Jin-Soo;Moon, Seung-Hyeon
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.03a
    • /
    • pp.1-11
    • /
    • 2004
  • Ion-exchange membranes have been widely used in various applications such as diffusion dialysis, electrolysis, electrodialysis, fuel cell etc [1-2]. When an electric current passes through the membrane system, the current is carried by both positive and negative ions in the bulk solution phases, whereas it is carried mainly by the counter-ions in the membrane. (omitted)

  • PDF

A Study on Fault Current Analysis for CCPU Connection (케이블 방식층보호장치의 결선방식에 대한 고장전류해석)

  • Jeong, Seong-Hwan;Choi, In-Huk
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.160-162
    • /
    • 1996
  • This paper is one-phase fault current analysis of 154kV underground transmission power cable. Its purpose is to gain knowleges of connect ing the CCPU and to show the merits as its method. There are many methods of connect ing CCPU, i.e, a conventional method, CIGRE method, interconnect ion between sheaths with grounding, and interconnect ion between sheaths without grounding. These methods will be compared in this paper.

  • PDF

Effect of Bogi, Boyang, Onri herbs pretreatment on glutamate ion current (보기, 보양, 온리약의 전처치가 glutamate current에 미치는 영향)

  • Kim, Chang-Ju;Kim, Youn-Jung;Kim, Hyun-Bae;Kim, Ee-Hwa;Lee, Choong-Yeol
    • Journal of Oriental Physiology
    • /
    • v.14 no.2 s.20
    • /
    • pp.67-82
    • /
    • 1999
  • The effects of Bogi, Boyang and Onri herbs on glutamte receptor, and the regulatory mechanism of cAMP-protein kinase on the ion currents activated by Bogi, Boyang and Onri herbs using nystatin-perforated patch clamp were investigated and the following results were obtained. Ginseng radix and Astragali radix, Cervi cornu and Boshniakiae herba, and Aconiti tuber and Zingiberis rhizoma were chosen as Bogi, Boyang and Onri herbs respectively. 1. The ion currents activated by $10^{-5}M$ of glycine were used as controls. The magnitudes of the ion currents by the above named herbs were as follows; Cervi cornu>Astragali radix>Aconiti tuber>Zingiberis rhizoma>Ginseng radix>Boshniakiae herba. 2. The magnitudes of the ion currents by $10^{-5}M$ of glutamate pre-treated with 0.01 mg/ml of Bogi, Boyang and Onri herbs were sharply decreased. 3. The activity of ion channels activated by Bogi herbs pre-treated with $10^{-7}M$ of staurosporin, an inhibitor of protein kinase, for thirty seconds was observed as the experiment proceeded. Staurosporin brought about dephosphorylation of ion channels. Hence, while the activity of ion channels activated by Ginseng radix was decreased, the activity of ion channels activated by Astragali radix was increased, as time went by. 4. The activity of ion channels activated by Boyang herbs pre-treated with $10^{-7}M$ of staurosporin, an inhibitor of protein kinase and an dephosphorylating agent of ion channels, for thirty seconds was investigated. While the activity of ion channels activated by Cervi cornu was increased, the activity of ion channels activated by Boshniakiae herba was initially increased then sharply decreased. 5, The activity of ion channels activated by Onri herbs pre-treated with $10^{-7}M$ of staurosporin, an inhibitor of protein kinase and an dephosphorylating agent of ion channels, for thirty seconds was investigated. While the activity of ion channels activated by Aconiti tuber was increased, that of ion channels activated by Zingiberis rhizomal sharply declined.

  • PDF

Understanding Ion Pump Emissions : Classification, Source Identification and Elimination of Emissions from Ion Pumps

  • Wynohrad, Tony
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.340-344
    • /
    • 2014
  • Ion pumps continue to be a staple in ultra-high vacuum (UHV) applications. Since their adoption as a primary UHV pump in the 1960's, it has been known that a variety of particles can emanate from within the ion pump and cause undesirable effects on current measurements and optics components. Historically the solution has been baffling and shielding which results in longer conductance paths to the ion pump. Those solutions can work, but require a larger pump and more vacuum plumbing to compensate for conductance losses. The first step was to fully understand the nature of the particles and their charges. Once those were characterized options for emissions reduction were evaluated. It was determined that an efficient design of shielding near the source of the particle generation site was the most cost effective solution. With a slight modification to the chamber of a small ion pump, internal shielding was developed that reduced the emissions by a factor of up to 1000 times.

SOLID STATE CESIUM ION BEAM SPUTTER DEPOSITION

  • Baik, Bong-Koo;Choi, Dong-Jun;Han, Dong-Won;Kim, Yong-Hwan;Kim, Seong-In
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.474-477
    • /
    • 1996
  • The solid state cesium ion beam sputter deposition system has been developed for negative carbon ion beam deposition. The negative carbon ion beams are effectively produced by cesium ion bombardment. The C-ion beam current and deposition energy can be independently controlled for the deposition of a-D films. This system is very compact, reliable and high flux without any gas discharge or plasma and has been successfully used in the studies of the ion beam deposited amorphous diamond(a-D)

  • PDF

Development and Testing of a Prototype Long Pulse Ion Source for the KSTAR Neutral Beam System

  • Chang Doo-Hee;Oh Byung-Hoon;Seo Chang-Seog
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.357-363
    • /
    • 2004
  • A prototype long pulse ion source was developed, and the beam extraction experiments of the ion source were carried out at the Neutral Beam Test Stand (NBTS) of the Korea Superconducting Tokamak Advanced Research (KSTAR). The ion source consists of a magnetic bucket plasma generator, with multi-pole cusp fields, and a set of tetrode accelerators with circular apertures. Design requirements for the ion source were a 120kV/65A deuterium beam and a 300 s pulse length. Arc discharges of the plasma generator were controlled by using the emission-limited mode, in turn controlled by the applied heating voltage of the cathode filaments. Stable and efficient arc plasmas with a maximum arc power of 100 kW were produced using the constant power mode operation of an arc power supply. A maximum ion density of $8.3{\times}10^{11}\;cm^{-3}$ was obtained by using electrostatic probes, and an optimum arc efficiency of 0.46 A/kW was estimated. The accelerating and decelerating voltages were applied repeatedly, using the re-triggering mode operation of the high voltage switches during a beam pulse, when beam disruptions occurred. The decelerating voltage was always applied prior to the accelerating voltage, to suppress effectively the back-streaming electrons produced at the time of an initial beam formation, by the pre-programmed fast-switch control system. A maximum beam power of 0.9 MW (i.e. $70\;kV{\times}12.5\;A$) with hydrogen was measured for a pulse duration of 0.8 s. Optimum beam perveance, deduced from the ratio of the gradient grid current to the total beam current, was $0.7\;{\mu}perv$. Stable beams for a long pulse duration of $5{\sim}10\;s$ were tested at low accelerating voltages.