• Title/Summary/Keyword: Ion Size

Search Result 1,137, Processing Time 0.028 seconds

Cloning and Characterization of a Methionine Aminopeptidase (MAP) Gene from Tetragenococcus halophilus CY54 Isolated from Myeolchi-Jeotgal

  • Tae Jin Kim;Min Jae Kim;Yun Ji Kang;Ji Yeon Yoo;Jeong Hwan Kim
    • Microbiology and Biotechnology Letters
    • /
    • v.51 no.1
    • /
    • pp.26-31
    • /
    • 2023
  • A map gene encoding methionyl-specific aminopeptidase (MAP; EC 3.4.11.18) was cloned from Tetragenococcus halophilus CY54. Translated amino acid sequence of CY54 MAP showed high similarities with those from Enterococcus faecalis (83.8%) and Streptococcus salivarius (62.2%) but low similarities with MAPs from Lactobacillus and Lactococcus genera. The map gene was overexpressed in E. coli BL21(DE3) using pET26b(+),pET26b(+), and the recombinant MAP was purified by using an Ni-NTA column. The size of recombinant MAP was 29 kDa as determined by SDS-PAGE. The optimum pH and temperature of CY54 MAP were pH 5.0 and 60℃, respectively. The activity of CY54 MAP was most significantly increased by Co2+ ion (159%), and showed the highest activity at 12% NaCl. Km and Vmax were 0.64 ± 0.006 mM and 10.12 ± 0.014 U/mg protein, respectively when met-pNA was used as the substrate. This is the first report on a MAP from Tetragenococcus species.

The Synthesis of Lithium Lanthanum Titanium Oxide for Solid Electrolyte via Ultrasonic Spray Pyrolysis (초음파 분무 열분해법을 이용한 고체전해질용 Lithium Lanthanum Titanium Oxide 제조)

  • Jaeseok, Roh;MinHo, Yang;Kun-Jae, Lee
    • Journal of Powder Materials
    • /
    • v.29 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Lithium lanthanum titanium oxide (LLTO) is a promising ceramic electrolyte because of its high ionic conductivity at room temperature, low electrical conductivity, and outstanding physical properties. Several routes for the synthesis of bulk LLTO are known, in particular, solid-state synthesis and sol-gel method. However, the extremely low ionic conductivity of LLTO at grain boundaries is one of the major problems for practical applications. To diminish the grain boundary effect, the structure of LLTO is tuned to nanoscale morphology with structures of different dimensionalities (0D spheres, and 1D tubes and wires); this strategy has great potential to enhance the ion conduction by intensifying Li diffusion and minimizing the grain boundary resistance. Therefore, in this work, 0D spherical LLTO is synthesized using ultrasonic spray pyrolysis (USP). The USP method primarily yields spherical particles from the droplets generated by ultrasonic waves passed through several heating zones. LLTO is synthesized using USP, and the effects of each precursor and their mechanisms as well as synthesis parameters are analyzed and discussed to optimize the synthesis. The phase structure of the obtained materials is analyzed using X-ray diffraction, and their morphology and particle size are analyzed using field-emission scanning electron microscopy.

Microstructure characterization technique of spacer garter spring coil X-750 material (스페이서 가터 스프링 코일 X-750 소재 정밀 조직 분석 방법)

  • Hyung-Ha Jin;I Seol Ryu;Gyeng-Geun Lee
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.109-118
    • /
    • 2021
  • In the periodic surveillance material test for the spacer component of fuel channel assembly in CANDU, a microstructural characterization analysis is required in addition to the mechanical property evaluation test. In this study, detailed microstructure analysis and simple mechanical property evaluation of archive spacer parts were conducted to indirectly support the surveillance test and assist in the study of spacer material degradation. We investigated the microstructural characteristics of the spacer garter spring coil through comparative analysis with the plate material. The main microstructure characteristics of the garter spring coil X-750 are represented by the fine grain size distribution, the ordering phase distribution developed inside the matrix, the high dislocation density inside the grains, and the arrangement of coarse carbides. In addition, the yield strength of the garter spring coil X-750 was indirectly evaluated to be approximately 1 GPa. We also established an analytical method to elucidate the microstructural evolution of the radioactive spacer garter spring coil X-750 based on Canadian research experiences. Finally, we confirmed the measurement technique for helium bubble formation through TEM examination on the helium implanted X-750 material.

A Study on Edge Detection Considering Center Pixels of Mask (마스크의 중심 화소를 고려한 에지 검출에 관한 연구)

  • Park, Hwa-Jung;Jung, Hwae-Sung;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.136-138
    • /
    • 2022
  • Edge detection includes information such as the shape, position, size, and material of an object with respect to an image, and is a very important factor in analyzing the characteristics of the image. Existing edge detection methods include Sobel edge detection filter, Roberts edge detection filter, Prewitt edge detection filter, and LoG (Lapacian of Gaussian) using secondary differentials. However, these methods have a disadvantage in that the edge detection results are somewhat insufficient because a fixed weight mask is applied to the entire image area. Therefore, in this paper, we propose an edge detection algorithm that increases edge detection characteristics by considering the center pixel in the mask. In addition, in order to confirm the proposed edge detection performance, it was compared through simulation result images.

  • PDF

Virus Purification by Membrane Chromatography: A Review (멤브레인 크로마토그래피에 의한 바이러스 정제 : 리뷰)

  • Gayatri Bhamidipatia;Rajkumar Patel
    • Membrane Journal
    • /
    • v.34 no.2
    • /
    • pp.124-131
    • /
    • 2024
  • Viruses have various applications in the biopharmaceutical industry. They are used in pesticide production, production of vaccines, gene transfers, cancer therapeutics, and more. The downstream processing of viruses is an essential step for their biological and pharmaceutical applications. Among the various processes, the purification of viruses is critical. Membrane chromatography plays a vital role in this process. While ion exchange membrane chromatography is a primarily used method, it has various limitations regarding size exclusion and insufficient purification. Also, it cannot be applied to the rapidly changing strains of viruses such as influenza. This review examines various improved methods of membrane chromatography or alternatives. It focuses on purification, viral recovery rates, and scalability of the methods.

Exposure Assessment of Airborne Hexavalent Chromium in the South Korea Plating Industry (도금사업장에서 발생하는 공기 중 6가 크롬의 노출평가)

  • Ji-hyun An;Young Gyu Phee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.98-105
    • /
    • 2024
  • Objectives: The purpose of this study was to identify the exposure level of airborne hexavalent chromium in the plating industry and the exposure level compared to domestic and international occupational exposure limits. Methods: A total 92 samples were collected from ten industrial plating sites. Hexavalent chromium samples were collected using a three-stage cassette equipped with a 37 mm, 5 ㎛ pore size PVC filter. The analysis was performed by ion chromatography. Results: The geometric mean of hexavalent chromium concentration in the plating industry was 0.052 ㎍/m2, and it was found that the average exposure level was 0.8 times the South Korean exposure limit. When applying the US ACGIH TLV, however, the average concentration was more than twice as high. Conclusions: The South Korean exposure limit for hexavalent chromium needs to be strengthened due to significant differences in exposure levels according to domestic and international occupational exposure limits. Furthermore, respiratory and dermal sensitization should be labeled.

Synthesis of Iron Phosphate Via Coprecipitation Method for LiFePO4 Cathode

  • Jeongwoo Lim;Seokwon Seo;Chunjoong Kim
    • Korean Journal of Materials Research
    • /
    • v.34 no.10
    • /
    • pp.482-490
    • /
    • 2024
  • In this study, ferric phosphate precursors were prepared by controlling precipitation time, and the resulting LiFe PO4 active materials were thoroughly investigated. Microscale LiFePO4 cathode materials, designed for high energy density at the cell level, were successfully synthesized through a 10 h co-precipitation. As the reaction time increased, smaller primary particles were aggregated more tightly, and the secondary particles exhibited a more spherical shape. Meanwhile, ammonia did not work effectively as a complexing agent. The carbon coated LiFePO4 (LiFePO4/C) synthesized from the 10 h ferric phosphate precursor exhibited larger primary and secondary particle sizes, a lower specific surface area, and higher crystallinity due to the sintering of the primary particles. Enhanced battery performance was achieved with the LiFePO4/C that was synthesized from the precursor with the smaller size, which exhibited the discharge capacity of 132.25 mAh·g-1 at 0.1 C, 70 % capacity retention at 5 C compared with 0.1 C, and 99.9 % capacity retention after the 50th cycle. The better battery performance is attributed to the lower charge transfer resistance and higher ionic conductivity, resulting from smaller primary particle sizes and a shorter Li+ diffusion path.

Synthesis of Uniform Silica Nanoparticles using Tap, Industrial, and Stream water and Their Application to Electro-responsive Smart Fluid System (상수, 공업용수, 및 하천수를 활용한 균일한 실리카 나노입자 합성 및 전기감응형 스마트유체로의 응용)

  • Ha-Yeong Kim;Suk Jekal;Neunghi Lee;Minki Sa;Dong Hyun Kim;Min Sang Kim;Jiwon Kim;Chang-Min Yoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.47-56
    • /
    • 2023
  • This study describes the successful synthesize strategy for the silica nanoparticles utilizing various water sources, including tap, industrial, and stream waters without using deionized water. Also, as-synthesized silica nanoparticles are employed as dispersive materials for the electro-responsive smart fluid application. Specifically, homogeneous silica nanoparticles with sizes of 500-700nm are successfully prepared in large scale at once (ca. 12.0 g) with the described experimental method and showing similar structural and chemical characteristics with silica nanoparticles synthesized using the deionized water. The size of silica nanoparticles are varied according to the ion conductivity differences of tap, industrial, stream water, and deionized water. The size of silica nanoparticles decresed with the increased ion conductivity, indicating the ion suppression of growth of silica nanoparticles. Moreover, as-synthesized silica nanoparticles from various water sources of electro-responsive characteristic are investigated by the smart fluid application. The smart fluids containing silica nanoparticles synthesized by tap, industrial, and stream water exhibited higher shear stress compared to the deionized water, owing to the more rigid fibril-like structures formed by the smaller silica nanoparticles. Conclusively, uniform silica nanoparticles from various water sources without any purification are able to successfully prepared without usage of deionized water and resulting silica nanoparticles manifested higher electro-responsive performance.

Synthesis and characterization of LiMn1.5Ni0.5O4 powders using polymerization complex method (착체중합법을 이용한 LiMn1.5Ni0.5O4 분말합성 및 특성평가)

  • Sin, Jae-Ho;Kim, Jin-Ho;Hwang, Hae-Jin;Kim, Ung-Soo;Cho, Woo-Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.4
    • /
    • pp.194-199
    • /
    • 2012
  • The $LiMn_{1.5}Ni_{0.5}O_4$, substituting a part of Mn with Ni in the $LiMn_2O_4$, the spinel structure has good charge-discharge cycle stability and high discharge capacity at 4.7 V. In this study $LiMn_{1.5}Ni_{0.5}O_4$ powders were synthesized by polymerization complex method. The effect on the characteristics of synthesized $LiMn_{1.5}Ni_{0.5}O_4$ powders was studied with citric acid (CA) : metal ion (ME) molar ratio (5 : 1, 10 : 1, 15 : 1, 30 : 1) and calcination temperature ($500{\sim}900^{\circ}C$). Single phase of $LiMn_{1.5}Ni_{0.5}O_4$ was observed from XRD analysis on the powders calcined at low ($500^{\circ}C$) and high temperatures ($900^{\circ}C$). The crystalline size and crystallinity increased with calcination temperature. At low calcination temperature the particle size decreased and specific surface area increased as the CA molar ratio increased. On the other hand, high particle growth rate at high calcination temperature interfered the particle size reduction and specific surface area increase induced by the increase of CA molar ratio.

BSF와 PSF를 이용한 TAR 비교

  • 박재홍;지영훈;오영기
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.40-40
    • /
    • 2003
  • 목적 : 현재 국내에서 사용중인 Co-60 원격치료용 방사선 조사장치의 경우 tissue air ratio(TAR)는 조사 표면에서 최대 선량을 가지는 back scatter factor(BSF)를 적용하여 구한 값을 사용하고 있는데, 실제로 Co-60 원격치료용 방사선 조사장치의 최대선량 깊이는 조사 표면이 아니라, 조사 표면에서 0.5cm 떨어진 거리에서 최대 선량을 나타내므로, BJR 25 에서 권장하는 값인 peak scatter factor(PSF)를 이용해 구한 값이 더 정확한 값으로 사료되기 때문에 이를 본 실험을 통해 검증하고자 하였다. 대상 및 방법 : 방사선 종양학과에서 치료용으로 사용하고 있는 Co-60 원격치료용 방사선 조사장치를 대상으로 하였다. BSF 는 Khan이 저술한 The Physics of Radiation Therapy의 부록에 제시된 값을 사용하였으며, PSF와 TAR를 구하기 위해 물 팬톰(water phantom), Farmer형 이온 챔버(ion chamber), 전기계(electrometer)를 사용하였다. PSF와 TAR를 구하기 위해서 몇 가지 측정을 하였다. 먼저, 공기 중에서 챔버를 SSD=80.5cm에 고정시킨 후, 방사선을 조사하여 선량을 측정하고, 깊이에 따른 선량을 알아보기 위해, 물 팬톰 내에 챔버를 SSD=80cm 고정시킨 후, 물을 서서히 채워가면서 5$\times$5cm, 10$\times$10cm, 15$\times$15cm, 20$\times$20cm, 30$\times$30cm의 field size에 대해서, 물의 깊이가 0.5cm-2cm 까지는 0.5cm 단위로 선량을 측정하고, 물의 깊이가 2cm-l4cm까지는 1cm단위로 선량을 측정하였다. 측정된 선량을 이용하여 PSF를 구하고 난 후, BJR 25에서 제시한 PSF와 비교를 하였고 TAR은 Khan이 제시한 변환식에 PSF를 대입하여 알아보았다. 기존의 TAR과 PSF를 이용해 구한 TAR을 측정하여 구한 TAR과 비교하였다. 결과 : BJR25에서 제시한 PSF와 본 실험에서 측정하여 얻은 PSF를 비교한 결과, field size가 5$\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.

  • PDF