• 제목/요약/키워드: Ion Size

검색결과 1,129건 처리시간 0.028초

표면적이 증가된 분별침전에 의한 paclitaxel의 입자 크기 감소 (Decrease in the Particle Size of Paclitaxel by Increased Surface Area Fractional Precipitation)

  • 이지연;김진현
    • 한국미생물·생명공학회지
    • /
    • 제40권2호
    • /
    • pp.157-162
    • /
    • 2012
  • In this study, we have for the first time applied increased surface area fractional precipitation in order to decrease the particle size of the anticancer agent paclitaxel from plant cell cultures. When compared with the case where no surface area increasing material was employed, the addition of ion exchange resin as a surface area increasing material resulted in a considerable decrease in the size of the paclitaxel precipitate. When ion exchange resin was used, the paclitaxel particles were four to five times smaller, having less than a 20 ${\mu}m$ radius, than those obtained in the absence of ion exchange resin. This is presumably because the growth of paclitaxel particles was impeded by the addition of ion exchange resin. The size of the paclitaxel precipitate also depended on the material used to increase the surface area, a result considered to be due to differences in the affinity between the particular ion exchange resin used and the paclitaxel particles. The yield of paclitaxel was significantly improved when ion exchange resin was used as a material to increase surface area. Paclitaxel, with a reduced particle size due to the addition of a surface area increasing material during the fractional precipitation process, is believed to be particularly useful for practical applications of the drug.

Optimum Radius Size between Cylindrical Ion Trap and Quadrupole Ion Trap

  • Chaharborj, Sarkhosh Seddighi;Kiai, Seyyed Mahmod Sadat;Arifin, Norihan Md;Gheisari, Yousof
    • Mass Spectrometry Letters
    • /
    • 제6권3호
    • /
    • pp.59-64
    • /
    • 2015
  • Quadrupole ion trap mass analyzer with a simplified geometry, namely, the cylindrical ion trap (CIT), has been shown to be well-suited using in miniature mass spectrometry and even in mass spectrometer arrays. Computation of stability regions is of particular importance in designing and assembling an ion trap. However, solving CIT equations are rather more difficult and complex than QIT equations, so, analytical and matrix methods have been widely used to calculate the stability regions. In this article we present the results of numerical simulations of the physical properties and the fractional mass resolutions m/Δm of the confined ions in the first stability region was analyzed by the fifth order Runge-Kutta method (RKM5) at the optimum radius size for both ion traps. Because of similarity the both results, having determining the optimum radius, we can make much easier to design CIT. Also, the simulated results has been performed a high precision in the resolution of trapped ions at the optimum radius size.

기능화된 탄소나노튜브 멤브레인의 이온 선택성에 관한 분자동역학 연구 (Molecular Dynamics Study to Investigate Ion Selectivity of Functionalized Carbon Nanotube Membranes)

  • 석명은
    • 멤브레인
    • /
    • 제28권6호
    • /
    • pp.388-394
    • /
    • 2018
  • 탄소나노튜브(CNT) 기반의 멤브레인은 높은 물 전달률과 직경에 따른 이온 배제율로 해수담수, 물질 정화 등을 위한 분리막으로써의 가능성을 보여 주었다. 이온 선택성은 CNT 기반 멤브레인의 응용 분야를 확대하기 위한 중요한 요소이며, 기능기를 이용하여 이온 선택성의 조절이 가능함이 보고되었다. 다양한 원자가/크기의 이온이 혼합될 경우, 이온-기능기간 작용력 뿐만 아니라 이온-이온간의 작용력, 이온의 크기에 의한 반발력 등이 복합적으로 작용한다. 이에 본 연구에서는 분자동역학 전산모사를 통하여, 상이한 원자가/크기를 가진 이온의 혼합이 기능화된 CNT의 이온 선택성에 미치는 영향을 연구하였다. Potential of Mean Force 계산을 통하여 이온 투과에 대한 자유 에너지 장벽을 계산하였으며, CNT 크기 변화, 전하량 변화를 통하여 이온 선택성과 배제에 영향을 미치는 요소를 분석하였다. 본 연구는 CNT 멤브레인을 이용한 분리막 설계, 생체 이온 전달 채널 모사 등에 유용할 것으로 기대한다.

천연제올라이트의 암모늄이온교환에 미치는 입자 크기 및 온도영향에 관한 연구 (Effects of Particle Size and Temperature on the Ammonium Ion Exchange by Natural Zeolite)

  • 송창수;김희준;정태학
    • 상하수도학회지
    • /
    • 제12권3호
    • /
    • pp.75-80
    • /
    • 1998
  • Ammonium ion is notorious for the adverse effects upon many of the important uses of water such as toxcity to fish, corrosion of metals and concrete, and concern over man's consumption. A clinoptilolite, which is a naturally occurring zeolite selective for ammonium ion exchange, has been used. Batch isotherm experiments were conducted for measuring ammonium ion exchange capacity. The ion exchange capacity was well described either by the Langmuir equation or by the Freundlich equation. As the particle size of the clinoptilolite decreased, exchange capacity was increased. The smaller particle size enhaced the exchange of ammonium ion due to the greater surface area and decreased diffusion to the exchange sites within the zeolite. Ammonium ion exchange capacity tended to decrease when the temperature increased from $20^{\circ}C$ to $35^{\circ}C$, and the temperature correction factor was found to be 0.98 in the Langmuir equation.

  • PDF

A Study on the Automatic Inspection System using Invariant Moments Algorithm with the Change of Size and Rotation

  • 이용중
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.164-169
    • /
    • 2003
  • The purpose of this study is to develop a practical image inspect ion system that could recognize it correctly, endowing flexibility to the productive field, although the same object for work will be changed in the size and rotated. In this experiment, it selected a fighter, rotating the direction from 30$^{\circ}$ to 45 simultaneously while changing the size from 1/4 to 1/16, as an object inspection without using another hardware for exclusive image processing. The invariant moments, Hu has suggested, was used as feature vector moment descriptor. As a result of the experiment, the image inspect ion system developed from this research was operated in real-time regardless of the chance of size and rotation for the object inspection, and it maintained the correspondent rates steadily above from 94% to 96%. Accordingly, it is considered as the flexibility can be considerably endowed to the factory automat ion when the image inspect ion system developed from this research is applied to the product ive field.

  • PDF

제주도 고산에서의 에어로솔 입경분포별 조성: 1998년 4월 측정 연구 (Aerosol Size Distribution and Composition at Kosan, Cheju Island : Measurements in April 1998)

  • 김용표;배귀남;지준호;진현철;문길주
    • 한국대기환경학회지
    • /
    • 제15권5호
    • /
    • pp.677-685
    • /
    • 1999
  • Aerosol mass size distributions were measured at Kosan, Cheju Island in April 1998 and their compositions were analyzed. Microorifice Uniform Deposit Impactor(MOUDI) was used to collect aerosols. Sulfate and ammonium ions were predominatly present at fine mode of the aerosols while nitrate, chloride, and metal ions were mostly at coarse mode. Based on the size distribution of nitrate, it is suggested that most nitrate were from gas to particle conversion on coarse particles. Non-sea salt(nss) fraction of sulfate accounted for more than 90% of total sulfate mass concentration. In general, ion concentrations in this study are lower than those measured at the same site from the previous studies. Ion balance and chloride ion levels indicates that there had been anthropogenic chloride emission sources near to the site during the measurements.

  • PDF

Modeling of sulfate ionic diffusion in porous cement based composites: effect of capillary size change

  • Gospodinov, Peter N.
    • Computers and Concrete
    • /
    • 제4권2호
    • /
    • pp.157-166
    • /
    • 2007
  • The paper considers a theoretical model to study sulfate ion diffusion in saturated porous media - cement based mineral composites, accounting for simultaneous effects, such as filling micro-capillaries (pores) with ions and chemical products and liquid push out of them. Pore volume change and its effect on the distribution of ion concentration within the specimen are investigated. Relations for the distribution of the capillary relative radius and volume within the composite under consideration are found. The numerical algorithm used is further completed to consider capillary size change and the effects accompanying sulfate ion diffusion. Ion distribution within the cross section and volume of specimens fabricated from mineral composites is numerically studied, accounting for the change of material capillary size and volume. Characteristic cases of 2D and 3D diffusion are analyzed. The results found can be used to both assess the sulfate corrosion in saturated systems and predict changes occurring in the pore structure of the composite as a result of sulfate ion diffusion.

The investigation of the carbon on irradiation hardening and defect clustering in RPV model alloy using ion irradiation and OKMC simulation

  • Yitao Yang;Jianyang Li;Chonghong Zhang
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2071-2078
    • /
    • 2024
  • The precipitation of solutes is a major cause of irradiation hardening and embrittlement limiting the service life of reactor pressure vessel (RPV) steels. Impurities play a significant role in the formation of precipitation in RPV materials. In this study, the effects of carbon on cluster formation and irradiation hardening were investigated in an RPV alloy Fe-1.35Mn-0.75Ni using C and Fe ions irradiation at 290 ℃. Nanoindentation results showed that C ion irradiation led to less hardening below 1.0 dpa, with hardening continuing to increase gradually at higher doses, while it was saturated under Fe ion irradiation. Atom probe tomography revealed a broad size distribution of Ni-Mn clusters under Fe ion irradiation, contrasting a narrower size distribution of small Ni-Mn clusters under C ion irradiation. Further analysis indicated the influence of carbon on the cluster formation, with solute-precipitated defects dominating under C ion irradiation but interstitial clusters dominating under Fe ion irradiation. Simulations suggested that carbon significantly affected solute nucleation, with defect clusters displaying smaller size and higher density as carbon concentration increased. The higher hardening at doses above 1.0 dpa was attributed to a substantial increase in the number density of defect clusters when carbon was present in the matrix.

황사기간도안 제주, 고산지역에서 호흡성 분진의 입자 분포 특성 (Characteristics According to the Size Distributions of Respirable Particulate During Yellow Sand Episode in Kosan, Jeju Island)

  • Kim, Jeong-Ho;Ahn, Jun-Young;Han, Jin-Seok;Lee, Jeong-Joo
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.91-96
    • /
    • 2003
  • This study was intended as an investigation of characteristics of background site atmospheric respirable particulate matters(RPM), and fine particles(<2.5 ${\mu}{\textrm}{m}$). The particle size distributions during the phenomenon of Yellow Sand(YS) occurs from April, 2001. Atmospheric aerosol particulate matter was directly collected on the Jeju island between 1 to 30, April, 2001 using an eight-stage cascade impacter(particle size range: 0.43-11 ${\mu}{\textrm}{m}$), and cyclone separator(cut size: 2.5, 10 ${\mu}{\textrm}{m}$). The episode of YS observed in background monitoring site, Kosan and appeared 2 times at sampling period. The mass concentrations of fine and coarse particles for YS episode were 34.2 and 59.6 $\mu\textrm{g}$/㎥, respectively, which were significantly increased amounts compared to 13.3 and 13.0 $\mu\textrm{g}$/㎥ for NonYS(NYS). Most size distributions had two peaks, one at 0.43∼.65 ${\mu}{\textrm}{m}$ and the other at 3.3${\mu}{\textrm}{m}$4.7 ${\mu}{\textrm}{m}$. The result of analysis of water-soluble ion component indicated that sulfate was mainly ion component, but nitrate and calcium ion was significantly increased at the YS episode.

이온교환수지 분체 특성에 대한 연구 (A Study on Characteristics of Pulverized Ion Exchange Resins)

  • 허재용;구경미;장용원;강상현
    • 멤브레인
    • /
    • 제34권2호
    • /
    • pp.132-139
    • /
    • 2024
  • Total dissolved solids (TDS) 제거에 이용되는 이온교환수지는 컬럼에 충진시켜 사용하게 되는데, 이온교환 과정에서 이온성 물질과 이온교환수지의 충분한 접촉시간을 필요로 한다. 본 연구에서는 이온교환수지의 분체화를 통하여 짧은 접촉시간으로도 높은 TDS 제거 성능을 보이는 이온교환수지의 특성을 연구하였다. 흐름성 등을 고려한 분체의 최적 크기는 100 ㎛ 이상임을 확인하였고, 250~500 ㎛d와 100~250 ㎛ 크기의 최대 분쇄 수율은 각각 67.3%와 36.9%였다. 또한 100~500 ㎛ 크기의 분쇄 수율은 분쇄 시간 2분에서 87.1%로 나타났다. 회분식(batch) 실험 조건에서 250~500 ㎛ 크기의 분체가 95%와 99%의 제거율에 도달하는 시간은 분쇄 전(non-pulverized) 이온교환수지에 비해 각각 1.82배와 1.96배 더 빨랐다. 100~250 ㎛ 크기의 분체는 각각 15.9배와 6.18배 더 빨랐다. 컬럼 테스트의 경우 분쇄 전 이온교환수지는 총 1.74 g, 250~500 ㎛ 크기의 분체는 1.83 g, 100~250 ㎛ 크기의 분체는 1.63 g의 NaCl을 제거하였다. 분체의 크기가 작아질수록 용량(capacity)이 약간 감소한 것으로 나타났다. 결과적으로 분체화된 이온교환수지를 사용하는 것이 접촉시간 대비 높은 TDS 제거 성능을 얻을 수 있는 방법임을 확인하였다.