RPCVD를 이용한 실리콘 게르마늄 이종 접합 바이폴라 트랜지스터 제작 및 특성 분석 (Fabrication and characterization of the SiGe HBTs using an RPCVD)

  • 한태현;서광열
    • 한국전기전자재료학회논문지
    • /
    • 제17권8호
    • /
    • pp.823-829
    • /
    • 2004
  • In this paper, non-self-aligned SiGe HBTs with ${f}_\tau$ and${f}_max $above 50 GHz have been fabricated using an RPCVD(Reduced Pressure Chemical Vapor Deposition) system for wireless applications. In the proposed structure, in-situ boron doped selective epitaxial growth(BDSEG) and TiSi$_2$ were used for the base electrode to reduce base resistance and in-situ phosphorus doped polysilicon was used for the emitter electrode to reduce emitter resistance. SiGe base profiles and collector design methodology to increase ${f}_\tau$ and${f}_max $ are discussed in detail. Two SiGe HBTs with the collector-emitter breakdown voltages ${BV}_CEO$ of 3 V and 6 V were fabricated using SIC(selective ion-implanted collector) implantation. Fabricated SiGe HBTs have a current gain of 265 ∼ 285 and Early voltage of 102 ∼ 120 V, respectively. For the $1\times{8}_\mu{m}^2$ emitter, a SiGe HBT with ${BV}_CEO$= 6 V shows a cut-off frequency, ${f}_\tau$of 24.3 GHz and a maximum oscillation frequency, ${f}_max $of 47.6 GHz at $I_c$of 3.7 mA and$V_CE$ of 4 V. A SiGe HBT with ${BV}_CEO$ = 3 V shows ${f}_\tau$of 50.8 GHz and ${f}_max $ of 52.2 GHz at $I_c$ of 14.7 mA and $V_CE$ of 2 V.

La(III) Selective Membrane Sensor Based on a New N-N Schiff's Base

  • Ganjali, Mohammad Reza;Matloobi, Parisa;Ghorbani, Maryam;Norouzi, Parviz;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권1호
    • /
    • pp.38-42
    • /
    • 2005
  • Bis(2-methylbenzaldehyde)butane-2,3-dihydrazone(TDSB) was used as new N-N Schiff's base which plays the role of an excellent ion carrier in the construction of a La(III) membrane sensor. The best performance was obtained with a membrane containing, 30% poly(vinyl chloride), 60% benzyl acetate, 6% TDSB and 4% sodium tetraphenyl borate. This sensor reveals a very good selectivity towards La(III) ions over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The proposed electrode exhibits a Nernstian behavior (with slope of 19.8 mV per decade) over a wide concentration range (1.0 ${\times}$ 10$^{-5}$-1.0 ${\times}$ 10$^{-1}$ M). The detection limit of the sensor is 7.0 ${\times}$ 10$^{-6}$ M. It has a very short response time, in the whole concentration range ($\sim$5 s), and can be used for at least twelve weeks in the pH range of 3.0-9.4. The proposed sensor was successfully applied as an indicator electrode for the potentiometric titration of a La(III) solution, with EDTA. It was also successfully applied in the determination of fluoride ions in three mouth wash preparations.

캘릭스[4]크라운 유도체를 이온선택성 물질로 사용한 납이온 선택성 막전극 (Lead Ion-Selective Electrode Based on Upper-rim Calix[4]crown Ionophore)

  • 남궁미옥;임혜재;백경수;윤영자
    • 대한화학회지
    • /
    • 제44권2호
    • /
    • pp.115-119
    • /
    • 2000
  • 새로운 캘릭스[4] 크라운 화합물을 이온 선택성 물질로 사용하고 지지체로 PVC(poly(vinylchloride)), 가소제로 DOS(Dioctyl sebacate}를 사용하여 막전극을 제작 하였다. 제작한 막전극을 지시전극으로 사용하여 알칼리, 알칼리토금속 이온 그리고 전이금속 이온에 대하여 각각의 감응전위를 측정한 결과, $10^{-6}{\sim}10^{-2}M\;Pb(NO_3)_2$ 용액에서 $Pb^{2+}$이온의 감응전위가 이론적인 Nernstian식 기울기에 가까운 27.0 mV/decade로 직선성이 잘 성립하는 감응전위를 나타내었다. $Pb^{2+}$ 이온 농도변화에 따른 막의 감응시간은 $t_{90}$=10 sec 이었고, 막의 사용기간은 2개월 정도이다. 또한 pH 영향을 조사해 본 결과 pH $2.0{\sim}12$ 범위에서 감응전위 값이 일정하게 유지되었다.

  • PDF

코어샘플을 이용한 질소 등 토양성분 현장 측정방법의 비교평가 (Comparison of In-Field Measurements of Nitrogen and Other Soil Properties with Core Samples)

  • 권기영
    • Journal of Biosystems Engineering
    • /
    • 제36권2호
    • /
    • pp.96-108
    • /
    • 2011
  • Several methods of in-field measurements of Nitrogen and other soil properties using cores extracted by a hydraulic soil sampler were evaluated. A prototype core scanner was built to accommodate Veris Technologies commercial Vis-NIRS equipment. The testing result for pH, P and Mg were close to RPD (Ratio of Prediction to Deviation = Standard deviation/RMSE) of 2, however the scanner could not achieve the goal of RPD of 2 on some other properties, especially on nitrate nitrogen ($NO_3$) and potassium (K). In situ NIRS/EC probe showed similar results to the core scanner; pH, P and Mg were close to RPD of 2, while $NO_3$ and K were RPD of 1.5 and 1.2, respectively. Correlations between estimations using the probe and the core scanner were strong, with $r^2$ > 0.7 for P, Mg, Total N, Total C and CEC. Preliminary results for mid-IR spectroscopy showed an $r^2$ of 0.068 and an RMSE for nitrate (N) of 18 ppm, even after the removal of calcareous samples and possible N outlier. After removal of calcareous samples on a larger sample set, results improved considerably with an $r^2$ of 0.64 and RMSE of 6 ppm. However, this was only possible after carbonate samples were detected and eliminated, which would not be feasible under in-field measurements. Testing of $NO_3$ and K ion-selective electrodes (ISEs) revealed promising results, with acceptable errors measuring soil solutions containing nitrate and potassium levels that are typical of production agriculture fields.

선택 건식에칭에 의한 단일 산화주석 나노와이어 소자의 접촉 특성 개선 (Improved Contact Characteristics in a Single Tin-Oxide Nanowire Device by a Selective Reactive Ion Etching (RIE) Process)

  • 이준민;김대일;하정숙;김규태
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.130-133
    • /
    • 2010
  • Although many structures based on $SnO_2$ nanowires have been demonstrated, there is a limitation towards practical application due to the unwanted contact potential between the metal electrode and the $SnO_2$ nanowire. This is mostly due to the presence of the native oxide layer that acts as an insulator between the metal contact and the nanowire. In this study the contact properties between Ti/Au contacts and a single $SnO_2$ nanowire was compared to the electrical properties of a contact without the oxide layer. RIE(Reactive Ion Etching) is used to selectively remove the oxide layer from the contact area. The $SnO_2$ nanowires were synthesized by chemical vapor deposition (CVD) and dispersed on a $Si/Si_3N_4$ substrate. The Ti/Au (20nm/100nm) electrodes were formed bye-beam lithography, e-beam evaporation and a lift-off process.

Organic Acid Extraction of Fluoride from Antarctic Krill Euphausia superba

  • Xie, Cheng Liang;Kim, Han Soo;Shim, Kil Bo;Kim, Yeon Kye;Yoon, Na Yeong;Kim, Poong Ho;Yoon, Ho Dong
    • Fisheries and Aquatic Sciences
    • /
    • 제15권3호
    • /
    • pp.203-207
    • /
    • 2012
  • The amount of fluoride removed from Antarctic krill via organic acid extraction depends on the extraction time, concentration, extraction volume, and the nature of the acid itself. The fluoride content in Euphausia superba was determined by measuring the concentration of fluoride ion in acidic extracts using an ion-selective electrode. The best results were obtained by adding 50 mL of 0.01 M citric acid to 0.3-0.5 g of krill and extracting for 5 min. Under these conditions, recoveries of fluoride from frozen whole krill and krill meat were 95.6-99.5% and 97.5-101.3%, respectively. The dry basis fluoride contents of krill by-product, krill meat and the boiled krill were 705, 298, and 575 ppm, respectively. These levels were significantly reduced by citric acid extraction.

Discriminant Analysis of Marketed Liquor by a Multi-channel Taste Evaluation System

  • Kim, Nam-Soo
    • Food Science and Biotechnology
    • /
    • 제14권4호
    • /
    • pp.554-557
    • /
    • 2005
  • As a device for taste sensation, an 8-channel taste evaluation system was prepared and applied for discriminant analysis of marketed liquor. The biomimetic polymer membranes for the system were prepared through a casting procedure by employing polyvinyl chloride, bis (2-ethylhexyl)sebacate as plasticizer and electroactive materials such as valinomycin in the ratio of 33:66:1, and were separately attached over the sensitive area of ion-selective electrodes to construct the corresponding taste sensor array. The sensor array in conjunction with a double junction reference electrode was connected to a high-input impedance amplifier and the amplified sensor signals were interfaced to a personal computer via an A/D converter. When the signal data from the sensor array for 3 groups of marketed liquor like Maesilju, Soju and beer were analyzed by principal component analysis after normalization, it was observed that the 1st, 2nd and 3rd principal component were responsible for most of the total data variance, and the analyzed liquor samples were discriminated well in 2 dimensional principal component planes composed of the 1st-2nd and the 1st-3rd principal component.

Fuzzy Clustering 알고리즘을 이용한 휴대용 전자 혀 개발 (Development of Portable Electronic Tongue using Fuzzy clustering algorithm)

  • 김정도;함유경;정우석;정영창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.602-604
    • /
    • 2004
  • A portable electronic tongue(E-Tongue) system using an array of ion-selective electrode(ISE) and personal digital assistants(PDA) for recognizing and analyzing food and drink have been designed. By the employment of PDA, the complex algorithm such as fuzzy c-means algorithm(FCMA) could be used in E-Tongue, FCMA could iteratively solve the cluster centers of pre-determined standard patterns. And the membership between the standard patterns and unknown pattern could be analyzed easily by the present E-Tongue combined with PDA.

  • PDF

Electrosorption of Uranium Ions in Liquid Waste

  • Lee, Hye-Young;Jung, Chong-Hun;Oh, Won-Zin;Park, Jin-Ho;Shul, Yong-Gun
    • Carbon letters
    • /
    • 제4권2호
    • /
    • pp.64-68
    • /
    • 2003
  • A study on the electrosorption of uranium ions onto a porous activated carbon fiber (ACF) was performed to treat uraniumcontaining lagoon sludge. The result of the continuous flow-through cell electrosorption experiments showed that the applied negative potential increased the adsorption kinetics and capacity in comparison to the open-circuit potential (OCP) adsorption for uranium ions. Effective U(VI) removal is accomplished when a negative potential is applied to the activated carbon fiber (ACF) electrode. For a feed concentration of 100 mg/L, the concentration of U(VI) in the cell effluent is reduced to less than 1 mg/L. The selective removal of uranium ions from electrolyte was possible by the electrosorption process.

  • PDF

Fuzzy C-Means Algorithm을 이용한 휴대용 전자혀 시스템 설계 (Design of a Portable Electronic Tongue System using Fuzzy C-Means Algorithm)

  • 김정도;김동진;함유경;정여창;윤철오
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.446-453
    • /
    • 2004
  • A portable electronic tongue (E-Tongue) system using an array of ion-selective electrode (ISE) and personal digital assistants (PDA) for recognizing and analyzing food and drink have been designed. By the employment of PDA, the complex algorithm such as fuzzy c-means algorithm (FCMA) could be used in E-Tongue, PUMA could iteratively solve the cluster centers of pre-determined standard patterns. And the membership between the standard patterns and unknown pattern could be analyzed easily by the present E-Tongue combined with PDA.