• Title/Summary/Keyword: Ion Current

Search Result 1,480, Processing Time 0.034 seconds

Research and Implementation of Using RF wireless Power Transmission System for Wireless Sensor Nodes Battery-Charging Power Harvesting Module (RF 무선전력전송을 이용한 센서노드 배터리 충전용 전력획득모듈 연구 및 구현)

  • Jung, Won-Jae;Park, Jun-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.34-42
    • /
    • 2011
  • With the progress of USN technology, fields to which wireless sensor node is applicable are increased under a condition that it holds a lot of problems to solve for betterment. One of the problems which acts as an obstacle to USN industry diffusion is the wireless sensor node battery exchange to their individual life cycle. Exchanging the battery of so many sensor nodes one by one requires a great deal of times and costs. Such problem is against the convenience supply -aim by applying USN technology. In this paper, using RF wireless power transmission system that power transmission / harvesting module from a distance of 5 m and the power of 10 dBm with a current of 1 mA or more for Sensor Nodes in lithium-polymer battery charging system tested and verified.

Nitric Oxide as a Pro-apoptotic as well as Anti-apoptotic Modulator

  • Choi, Byung-Min;Pae, Hyun-Ock;Jang, Seon-Il;Kim, Young-Myeong;Chung, Hun-Taeg
    • BMB Reports
    • /
    • v.35 no.1
    • /
    • pp.116-126
    • /
    • 2002
  • Nitric oxide (NO), synthesized from L-arginine by NO synthases, is a small, lipophilic, diffusible, highly reactive molecule with dichotomous regulatory roles in many biological events under physiological and pathological conditions. NO can promote apoptosis (pro-apoptosis) in some cells, whereas it inhibits apoptosis (anti-apoptosis) in other cells. This complexity is a consequence of the rate of NO production and the interaction with biological molecules such as metal ion, thiol, protein tyrosine, and reactive oxygen species. Long-lasting overproduction of NO acts as a pro-apoptotic modulator, activating caspase family proteases through the release of mitochondrial cytochrome c into cytosol, up-regulation of the p53 expression, and alterations in the expression of apoptosis-associated proteins, including the Bcl-2 family. However, low or physiological concentrations of NO prevent cells from apoptosis that is induced by the trophic factor withdrawal, Fas, $TNF{\alpha}$/ActD, and LPS. The anti-apoptotic mechanism is understood on the basis of gene transcription of protective proteins. These include: heat shock protein, hemeoxygenase, or cyclooxygenase-2 and direct inhibition of the apoptotic executive effectors caspase family protease by S-nitrosylation of the cysteine thiol group in their catalytic site in a cell specific way. Our current understanding of the mechanisms by which NO exerts both pro- and anti-apototic action is discussed in this review article.

A Fabrication and Properties of Ionization Chamber Using Madium Exposure Rate (중준위 조사선량율 측정용 전리함의 설계 및 특성)

  • Woo, Hong;Kim, Sung-Hwan;Kang, Hee-Dong
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.29-40
    • /
    • 1996
  • We had designed and made the cylindrical ionization chamber which operated above 5 mR/h. Using commercial electrometer, we investigated the characterictic of charge collection in the ion chamber. The active volume was 190.4㎤ and overall length and diameter in the chamber was 15.5cm, 5.22cm, respectively. The chamber had three electrodes(inner, central, wall electrode). And background current was 8.39${\times}$10$\^$-14/${\pm}$1.5${\times}$10$\^$-15/A to arrange the electrodes which were coaxial in chamber axis. The collection efficiency of chamber for Cs$\^$137/ was 99.7% when the opreating voltage was applied 400V. Comparing with the commertial dosimetry system, the exposure calibration constant was 4.531${\times}$19$\^$7/R/C. By normalizing to CS$\_$137/ the relative energy response of the chamber was 1.30 for Am$\_$24/, 1.05 for C0$\_$60/, respectively. When the irrarition tranversed to the chamber axis, the isotropic effect of the chamber was not considerable.

  • PDF

Kinetic Study on SNAr Reaction of 1-Y-Substituted-phenoxy-2,4-dinitrobenzenes with Hydroxide Ion: Effect of Substituent Y on Reactivity and Reaction Mechanism

  • Kang, Tae-Ah;Cho, Hyo-Jin;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.7
    • /
    • pp.2135-2138
    • /
    • 2014
  • A kinetic study is reported for the SNAr reaction of 1-Y-substituted-phenoxy-2,4-dinitrobenzenes (1a-1h) with OH- in 80 mol % $H_2O$/20 mol % DMSO at $25.0{\pm}0.1^{\circ}C$. The second-order rate constant ($k_{OH^-}$) increases as the substituent Y in the leaving group changes from an electron-donating group (EDG) to an electronwithdrawing group (EWG). The Br${\o}$nsted-type plot for the reactions of 1a-1h is linear with ${\beta}_{lg}$ = -0.16, indicating that the reactivity of substrates 1a-1h is little affected by the leaving-group basicity. A linear Br${\o}$nsted-type plot with ${\beta}_{lg}=-0.3{\pm}0.1$ is typical for reactions reported previously to proceed through a stepwise mechanism in which formation of a Meisenheimer complex is the rate-determining step (RDS). The Hammett plot correlated with ${\sigma}_Y{^{\circ}}$ constants results in a much better correlation than that correlated with ${\sigma}_Y{^-}$constants, implyng that no negative charge is developing on the O atom of the leaving group (or expulsion of the leaving group is not advanced at all in the TS). This excludes a possibility that the $S_NAr$ reaction of 1a-1h with $OH^-$ proceeds through a concerted mechanism or via a stepwise pathway with expulsion of the leaving group being the RDS. Thus, the current reactions have been concluded to proceed through a stepwise mechanism in which expulsion of the leaving group occurs rapidly after the RDS.

Chemically Modified Electrodes and Their Applications to Electrocatalysis-Poly-MePMP+BF4-/Ferri-ferrocyanide/Ascorbic Acid System (기능성 전극의 전기촉매로의 응용-Poly-MePMP+BF4-/Ferri-Ferri-ferrocyanide/Ascorbic Acid계)

  • Chang, Dong-Hun;Oh, Seung-Mo
    • Applied Chemistry for Engineering
    • /
    • v.3 no.1
    • /
    • pp.138-147
    • /
    • 1992
  • Chemically-modified electrodes were fabricated and their electrocatalytic behaviors have been investigated. As a modifying layer, poly-[1-methyl-3-(pyrrol-1-ylmethyl) pyridinium] was electropolymerized onto Pt electrodes under constant current. The thickness of the polymer film was controlled by means of total charge consumed during the electropolymerization. SEM was used to measure the thickness. There was a linear relationship between the passed charge and the film thickness. Ferro/ferricyanide, used as an electron mediator in this study, was rapidly ion-exchanged into the polymer layer with its concentration of 1.2~1.3M. It was found that electrooxidation of ascorbic acid is catalyzed by incorporated ferri/ferrocyanide couple. Kinetic parameters for electrooxidation were determined by RDE experiments. The results indicate that the present system corresponds to ER+S case based on the Saveant theory. Improving methods have been proposed to be R+S case which is ideal for electrocatalysis.

  • PDF

Studies on the Semicarbazone Formation of Monosubstituted Benzaldehydes (모노장쇄(長鎖)알킬카르복시 베타인류(類)의 미셀 형성(形成)에 관(關)한 연구(硏究))

  • Nam, Ki-Dae;Jeong, No-Hee;No, Sueng-Ho;Kim, Yu-Bae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.13-24
    • /
    • 1990
  • 2-N,N,N-trimethyl ammonia decanoate, 2-N,N,N-trimethyl ammonio dodecanoate, 2-N,N,N-trimethyl ammonia tetradecanoate and 2-N,N,N-hexadecanoate with in straight long chain alkyl carboxybetaines, and N-decyl N,N-dimethyl ammonio ethanoate, N-dodecyl N,N-dimethyl ammonia ethanoate, N-tetradecyl N,N-dimethyl ammonia ethanoate and N-hexadecyl N,N-dimethyl ammonia ethanoate with in nitrogen-straight long chain alkyl carboxy betaines measured respectively surface tensions by the stalagmometer method at various temperature, also their critical micelle concentration were evaluated. In micellization, the contribution of standard free energy change(${\Delta}G^{\circ}m$), standard enthalpy change(${\Delta}H^{\circ}m$) and standard entropy change (${\Delta}S^{\circ}m$), have been calculated, with increasing temperature. ${\Delta}H^{\circ}m$ changes from negative, and a similar change in the sign of ${\Delta}H^{\circ}m$ is observed with increasing chain length at $25^{\circ}C$, while the entropy of micellization, ${\Delta}S^{\circ}m$ is positive over the temperature range studied, it becomes less so at higher temperatures. Estimates of the enthalpy and entropy contribution attributable to the ion head group and alkyl chain have been made. The enthalpy and entropy change, per methylene group increase respectively with increasing chain length the result are discussed in terms of current theories of micellization.

Study on the IPMC electrical characteristic change For the utilization of Ocean Current Energy (해양 에너지 활용을 위한 IPMC의 전기적 특성 변화 연구)

  • Son, Kyung Min;Kim, Min;Kim, Gwan-Hyung;Kim, Hyun-jo;Byun, Gi-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.531-533
    • /
    • 2013
  • In this paper, to study the IPMC (Ionic exchange Polymer Metal Composite) material consisting of a sulfonic acid ion and fluoride combination of carbon with Nafion film greatly affected the electro-active polymer (Electro Active Polymer) characteristics and the presence of water and cationshave properties. Use or electrical energy into mechanical energy, mechanical energy, electrical energy, and can be utilized to its characteristics, depending on the water and cations in water varies greatly. Configure the device simulations in order to study the electrical properties of these IPMC. Stepper Motor using MCU and simulator designed for the electrical characterization due to the movement and to the implementation of the mechanical movement of ocean currents. In this study, configuration the IPMC and simulation device to the area of the IPMC to the efficient use of energy currents, frequency, salinity concentration, through the efficient use of the IPMC due to the bend angle of the electrical analysis and research methods we propose.

  • PDF

A study on the SEI film formation as organic solvent decomposition of lithium ion batteries and its electrochemical behavior (리튬이온전지의 유기용매분해에 따른 SEI film 형성과 전기화학적 거동에 관한 연구)

  • Kim, Min-Seong;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.545-549
    • /
    • 2001
  • We have produced electrolyte solution out of 1.15M $LiPF_6$ EC/EMC/DEC/PC(30/55/10/5 by vol%) as a reference, and at the same time, performed basic physical property test using a single solvent of 1.15M $LiPF_6$ DEC, DMC, EMC and a 2 component electrolyte solution of 1.15M $LiPF_6$ EC/DEC(1/2 by vol%) and PC/DEC(1/2 by vol%). Cyclic Voltammetry Analysis showed that, compared to existing carbonate organic solvent, the addition of DEC,DMC and EMC brought the de-decomposition peak of salt anion of $PF_6$ and the solvent at lower oxidization potential of 2.3V, 0.7V and 2.1V(vs. $Li/Li^+$). In addition, a kinetics current peak, in which intercalation of Lt is proceeded at 750mV, 450mV(vs. $Li/Li^+$), was confirmed. These findings suggest that the DEC solvent decomposition occurred at an electric potential lower than that of oxidization of existing carbonate organic solvent. Through the impedance analysis, we checked electric charge transfer resistance($R_{ct}$) according to the electric potential of $Li^+$ intercalation at 750mV(vs. $Li/Li^+$), which was the same as the resistance ($R_f$) and cyclic voltammetry of SEI film that was formed at Reference. By doing so, we found that the significant decrease of polarization resistance($R_p$) when Reference was played a part in the formation of compact SEI layer at the initial decomposition reaction.

  • PDF

Control of Copper Thin Film Characteristics by using Pulsed DC Power Magnetron Sputter System (Pulsed DC Power Magnetron Sputter System을 사용한 Copper 박막 특성 조절)

  • Kim, Do-Han;Lee, Su-Jeong;Kim, Tae-Hyeong;Lee, Won-O;Yeom, Won-Gyun;Kim, Gyeong-Nam;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.107-107
    • /
    • 2017
  • 전자제품의 성능이 향상됨에 따라서 전자제품에 사용되는 부품의 고집적화가 필연적으로 요구되고 있으며, 고집적화 된 전자제품의 방열(heat dissipation)에 관한 문제점이 대두되고 있다. 방열은 전자기기의 성능과 수명을 유지하는데 있어서 중요한 문제 중 하나로서 방열 효과를 높이기 위해 다양한 연구 개발이 진행 중이다. 방열에 사용되는 소재로는 Cu가 있으며, 저렴한 가격과 상대적으로 높은 방열 효율을 가지는 장점이 있다. Cu는 전기 도금 증착 방법을 사용하여왔으나, 전기도금 방식으로 증착된 Cu 방열판은 제품에 열이 축적될 경우 Cu와 substrate 사이의 residual stress로 인해 박리나 뒤틀림 현상 등이 발생하여 high power를 사용하는 device의 방열 소재로 사용하기에는 개선해야 할 문제점이 있다. 이러한 문제점을 극복하기 위한 방법으로 magnetron sputter 증착 방법이 있으며, magnetron sputter은 대면적화가 용이하고, 다양한 물질의 증착이 가능한 장점으로 인해 hard coating 또는 thin film 증착과 같은 공정에 사용되고 있다. 특히 증착된 film의 특성을 조절하기 위해서 magnetron sputter에 pulse 또는 ICP (inductively coupled plasma) assisted 등을 적용하여 plasma 특성을 조절하는 방법 등에 관한 연구가 보고되고 있다. 본 연구에서는 pulsed magnetron sputtering 방식을 이용하여 증착된 Cu film 특성 변화를 확인하였다. 다양한 pulsing frequency와 pulsing duty ratio 조건에서, Si substrate 위에 증착된 Cu film과의 residual stress 변화를 측정하였다. Pulse duty ratio가 90% 에서 60%로 감소함에 따라서 Cu film의 residual stress가 감소하였고, pulsing frequency가 증가함에 따라 Cu film의 residual stress가 감소하는 것을 확인하였다. 증착 조건에 따른 plasma의 특성 분석을 위하여 oscilloscope를 이용하여 voltage와 current를 측정하였고, Plasma Sampling Mass spectrometer 를 이용하여 ion energy의 변화를 측정하였다. 이를 통해 plasma 특성 변화가 증착된 Cu film에 미치는 영향과 residual stress의 변화에 대한 연관성에 대하여 확인할 수 있었다.

  • PDF

Normal data on axonal excitability in Koreans

  • Lee, Ju Young;Yu, Jin Hyeok;Pyun, So Young;Ryu, Sanghyo;Bae, Jong Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.1
    • /
    • pp.34-39
    • /
    • 2017
  • Background: Automated nerve excitability testing is used to assess various peripheral neuropathies and motor neuron diseases. Comparing these excitability parameters with normal data provides information regarding the axonal excitability properties and ion biophysics in diseased axons. This study measured and compared normal values of axonal excitability parameters in both the distal motor and sensory axons of normal Koreans. Methods: The axonal excitability properties of 50 distal median motor axons and 30 distal median sensory axons were measured. An automated nerve excitability test was performed using the QTRACW threshold-tracking software (Institute of Neurology, University College London, London, UK) with the TRONDF multiple excitability recording protocol. Each parameter of stimulus-response curves, threshold electrotonus, current-voltage relationship, and recovery cycle was measured and calculated. Results: Our Korean normal data on axonal excitability showed ranges of values and characteristics similar to previous reports from other countries. We also reaffirmed that there exist characteristic differences in excitability properties between motor and sensory axons: compared to motor axons, sensory axons showed an increased strength-duration time constant, more prominent changes in threshold to hyperpolarizing threshold electrotonus (TE) and less prominent changes in threshold to depolarizing TE, and more prominent refractoriness and less prominent subexcitability and superexcitability. Conclusions: We report normal data on axonal excitability in Koreans. These data can be used to compare various pathological conditions in peripheral nerve axons such as peripheral neuropathies and motor neuron disease.