• Title/Summary/Keyword: Ion/surface Collisions

Search Result 7, Processing Time 0.017 seconds

Hyperthermal Collision-induced Dissociation of Bromotoluene Radical Cations at Self-Assembled Monolayer Surfaces

  • Jo, Sung-Chan;Augusti, Rodinei;Cooks, R. Graham
    • Mass Spectrometry Letters
    • /
    • v.2 no.1
    • /
    • pp.24-27
    • /
    • 2011
  • Hyperthermal ion/surface collisions of bromotoluene radical cations were studied using perfluorinated (F-SAM) and hydroxyl-terminated (OH-SAM) self-assembled monolayer surfaces in a tandem mass spectrometer with BEEQ geometry. The isomers were differentiated by ion abundance ratios taken from surface-induced dissociation (SID). The dissociation rate followed the order of ortho > meta > para isomers. The peak abundance ratio of m/z 51 to m/z 65 showed the best result to discern the isomers. A dissociation channel leading to tolylium ion was suggested to be responsible for the pronounced isomeric differences. The capability of SID to provide high-energy activation with narrow internal energy distribution may have channeled the reaction into the specific dissociation pathway, also facilitating small differences in reaction rates to be effective in the spectral time window of this experiment. All of the molecular ions experiencing reactive collisions with the F-SAM surface undergo transhalogenation, in which a fluorine atom on the surface replaces the bromine in the incoming ions. This reactive collision was dependent on the laboratory collision energy occurring in ca. 40.75 eV range.

Scattering of Noble Gas Ions from a Si(100) Surface at Hyperthermal Energies (20-300 eV)

  • 이현우;Kang, H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.2
    • /
    • pp.101-104
    • /
    • 1995
  • In an attempt to understand the nature of hyperthermal ion-surface collisions, noble gas ion beams (He+, Ne+, Ar+, and Xe+) are scattered from a Si(100) surface for collision energies of 20-300 eV and for 45°incidence angle. The scattered ions are mass-analyzed using a quadrupole mass spectrometer and their kinetic energy is measured in a time-of-flight mode. The scattering event for He+ and Ne+ can be approximated as a sequence of quasi-binary collisions with individual Si atoms for high collision energies (Ei > 100 eV), but it becomes of a many-body nature for lower energies, Ar+ and Xe+ ions undergo mutliple large impact parameter collisions with the surface atoms. The effective mass of a surface that these heavy ions experience during the collision increases drastically for low beam energies.

Characteristics of Polymer irradiated by Low energy Ion Beam

  • sung Han;Yoon, Ki-Hyun;Jung, Hyung-Jin;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.109-109
    • /
    • 1999
  • Recently, low energy ion beam irradiation has been adopted for surface modification. Low energy ion beam irradiation has many advantages in polymer engineering such as weak damage, good adhesion, noticeably-enhanced wettability(less than 15 degree), good reproducibility and so on. In this experiment, chemical reactions between free radicals and environment gas species have been investigated using angle-resolved XPS and TRIM code. In the case of low ion beam energy (around 1 keV), energy loss in polymer is mainly originated from atomic collisions instead of electronic interference. Atomic collisions could generated displaced atoms and free radicals. Cold cathode-ion source equipped with 5cm convex grid was used in an O2 environment. Base and working pressure were 5$\times$10-6 and 2.3$\times$10-4 Torr. Flow rates of argon and oxygen were fixed at 1.2 and 8 sccm. target materials are polyethylene polyvinyidenefluoride and polytetrafluoroethylene.

  • PDF

Simulation of a Langmuir Probe in an ECR Reactor (ECR Reactor 내의 Langmuir Probe 시뮬레이션)

  • Kim, Hoon;Porteous, Robert K.;Boswell, Rod W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1609-1611
    • /
    • 1994
  • In ECR and helicon reactors for plasma processing, a high density plasma is generated in a source region which is connected to a diffusion region where the processing takes place. Large density and potential gradients can develop at the orifice of the source which drive ion currents into the diffusion region. The average ion velocity may become the order of the sound velocity. Measurements of the ion saturation current to a Langmuir probe are used as a standard method of determining the plasma density in laboratory discharges. However, the analysis becomes difficult in a steaming plasma. We have used the HAMLET plasma simulator to simulate the ion flow to a large langmuir probe in an ECR plasma. The collection surface was aligned with the Held upstream, normal to the field, and downstream. ion trajectories through the electric and magnetic fields were calculated including ion-neutral collisions. We examines the ratio of ion current density to plasma density as a function of magnetic field and pressure.

  • PDF

Hydrophilic property by contact angle change of ion implanted polycarbonate (이온주입 Polycarbonate의 접촉각 변화에 의한 친수특성)

  • Lee, Chan-Young;Lee, Jae-Hyung;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.533-538
    • /
    • 2003
  • It has been shown that ion implantation produces remarkable improvements in surface-sensitive physical and chemical properties as well as other mechanical properties, in polymers. In this study, ion implantation was performed onto polymer, PC(polycarbonate), in order to investigate surface hydrophilic property through contact angle measurement using distilled water. PC was irradiated with N, Ar, Xe ions at the irradiation energy of $20\;{\sim}\;50keV$ and the dose range of $5{\times}10^{15},\;1{\times}10^{16},\;7{\times}10^{16}\;ions/cm^2$. The contact angle of water has been reduced with increasing fluence and ion mass but increased with increasing implanted energy. The changes of chemical and structural property are discussed in view of infrared spectroscopy and FT-IR, XPS, which shows increasing C-O bonding and C-C bonding. The root mean square of surface roughness examined by means of AFM changed smoothly from 0.387nm to 0.207nm and the change of wettability was discussed with respect to elastic and inelastic collisions obtained as results of TRIM simulation. It was found that wettability of the modified PC surface was affected on change of functional group and nuclear stopping or linear energy transfer(LET, energy deposited per unit track length per ion) that causes chain scission by displacing atom from polymer chains, but was not greatly dependant on surface morphology.

  • PDF

Characterization of a Magnetron Sputtering Cathode by a 3D Particle Model (3차원 입자 모델을 이용한 마그네트론 스퍼터링 음극의 특성 분석)

  • Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.5
    • /
    • pp.205-213
    • /
    • 2008
  • A 3D particle code is developed to analyze electron behavior in a planar magnetron sputtering cathode either in balanced or unbalanced configuration. Three types of collisions are included; electron - neutral elastic, excitation to a metastable state and ionization. Flight path is calculated by a 4-th order Runge-Kutta method with a time step of 10 ps. Effects of electron starting position, magnetic field intensity and configuration were analyzed. For a more efficient and accurate modeling, multithreading technique is considered for multicore CPU computers. Under an assumption of cold ion approach, target erosion profiles are predicted for a flat target surface.