• Title/Summary/Keyword: Investigation cost

Search Result 896, Processing Time 0.027 seconds

A Study on the Development of Envi-Cone Penetrometer System (지반환경조사용 환경콘 관입시스템 개발을 위한 기초연구)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.247-254
    • /
    • 1999
  • In recent years there has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation of contaminant in the ground. There are many techniques such as geophysical, drilling, sampling, and pushing techniques for investigation of contaminated ground. The most rapidly developing site characterization techniques for geoenvironmental purposes Involve direct push technology, that is, penetration tests. In this study, the envi-cone penetrometer system is developed by modification of traditional cone penetration test. The electrical resistivity sensor, pH sensor, thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective.

  • PDF

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식의 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1281-1283
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors a net size, weight, and parts cost saying result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Investigation and Analysis of Interruption Characteristics for Industrial Customers

  • Choi, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.45-52
    • /
    • 2007
  • Electric power is an important element in any modern economy. The availability of a reliable power supply at a reasonable cost is important for the economic growth and development of a country. Electric power utilities throughout the world therefore strive to meet customer demands economically with high quality and reliability. As the power industry moves towards open competition, therefore, there has been a call for a methodology by which to evaluate power system reliability through the use of customer interruption characteristics. This paper presents the results of an investigation and analysis of interruption characteristics of an industrial customer in Korea. This study used a direct visit survey to determine the investigation and analysis of electric service quality and the characteristics of industrial customers in Korea. A customer survey conducted throughout Korea via personal interviews of 660 sample customers is presented here. Variation according to characteristics of interruption such as duration, time of day, frequency and day of interruption was also investigated

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.467-469
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier, four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Study on Consideration Plan of Environmental Influence in Preliminary Feasibility Investigation of Railroad Work (철도사업의 예비타당성조사시 환경영향 고려방안에 관한 연구)

  • Sun, Hyo-Sung;Park, Young-Min
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1178-1183
    • /
    • 2006
  • This paper describes the plans of considering the environmental influences in the preliminary feasibility investigation of railroad work. Because the cost-benefit analysis method about the environmental costs by air pollution and traffic noise is mainly applied in preliminary feasibility investigation, not only the verification in the calculation method of these environmental costs but also the consideration in the environmental costs of the topographical damage and the ecosystem extinction by railroad work is needed. The environment-friendly plans in choosing the locations of the railroad route and station are also suggested, and they include (1) consideration of environment protection area, residential zone, and region with scenic beauty, (2) application of the existing railroad route and station, and (3) railroad route parallel to another traffic facility.

  • PDF

High-Frequency DC Link Inverter for Grid-connected PV System (계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터)

  • Jung Young-Seok;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

An Investigation of the Relationship between Revenue Water Ratio and the Operating and Maintenance Cost of Water Supply Network (상수관망 유수율과 유지관리 비용의 관계 분석)

  • Kim, Jaehee;Yoo, Kwangtae;Jun, Hwandon;Jang, Jaesun
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.202-212
    • /
    • 2012
  • Due to the deterioration of water supply network and the deficiency of raw water, the water utility of local governments have performed various projects to improve their revenue water ratio. However, it is very difficult to estimate the cost for maintaining the revenue water ratio at higher level after completing the project, because local governments have different conditions affecting the operating and maintenance cost of water supply network. The purpose of this study is to present a procedure to estimate the operating and maintenance cost required to maintain the target revenue water ratio of the water supply network. For this purpose, we estimated the cost used only for operation and maintenance of water supply network of 164 local governments with the aid of K-Mean Clustering Analysis and the data from 40 representative local governments. Then, the regression analysis was performed to find relationship between revenue water ratio and the operating and maintenance cost with two different data sets generated by two classification methods; the first method classifies the local governments by means of k-means clustering, and the other classifies the local governments according to the index standardized by the operating and maintenance cost per unit length of water mains per revenue water ratio. The results shows that the method based on the index standardized by the cost and revenue water ratio of each government produces more reliable results for finding regression equations between revenue water ratio and the operating and maintenance cost only for water supply network. The estimated regression equations for each group can be used to estimate the cost required to keep the target revenue water ratio of the local government.

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

Income Analysis of Orange Farming in China (중국 밀감재배의 소득분석)

  • Kim, Jai-Hong;Pan, Li
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.2
    • /
    • pp.233-244
    • /
    • 2009
  • This study analyzed the income of orange farming of Lichuan, Jiangxi Province in China. Using a questionnaire, 36 farmhouseholds of Lichuan were surveyed. The results are as follows. First, through the investigation of Lichuan orange farming farmhouseholds, we know that the direct expenses of Lichuan orange is around 2,250 RMB/10a and the direct expenses per household's are about 32,000 RMB. The average production of Lichuan orange is 1,548 kg/10a and the income is around 2,200 RMB/10a. The results showed that in Lichuan area orange farming benefit is more than rice so orange farming has been increasing. Second, the direct expense of Lichuan orange farming, 91% is material cost, 8% is labor cost, depreciation cost is only 1.4%. This result show that orange farming in Lichuan is very labor intensive. Third, there are a lots of young orange trees in Lichuan, so income would be increasing through the year.

  • PDF