• 제목/요약/키워드: Inverter-fed induction motor (IFM)

검색결과 2건 처리시간 0.017초

인버터 구동 유도전동기에서 과도전압의 측정과 분석 (Measurement and Analysis of Transient Overvoltages on Inverter-fed Induction Motors)

  • 박대원;김일권;최수연;박찬용;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1445-1450
    • /
    • 2007
  • Induction motors are the main driving force of electric vehicles and operated by pulse width modulation (PWM) inverters in speed control. Contrary to full-voltage operation of induction motors, inverter-fed induction motors (IFM) generates transient overvoltages up to 10 kV/us and transient overvoltages accelerate the deterioration of winding insulation. We investigated transient overvoltages produced by the operation of IFM and analyzed its peak value and dv/dt depending on power cable length and operation frequency. The experimental results showed that transient overvoltages measured at the motor terminal increased with the cable length between inverter and motor.

  • PDF

인버터 구동 유도전동기에서 과도전압의 측정과 분석 (Measurement and Analysis of Transient Voltage for an Inverter-fed Induction Motor)

  • 길경석;류길수;박대원;조영진;천상규;최수연
    • 한국철도학회논문집
    • /
    • 제10권6호
    • /
    • pp.650-654
    • /
    • 2007
  • 유도전동기는 전기차량의 주요 동력원으로 광범위하게 사용되고 있으며, 유도전동기의 속도제어에 펄스변조 방식을 이용한 인버터의 사용이 증가하고 있다. 본 논문에서는 유도전동기의 인버터 구동시 발생하는 과도전압에 대해 연구하였다. 전원 케이블의 길이에 따른 과도전압의 크기를 측정하였으며, 시간변화율과 운전주파수에 의한 영향을 분석하였다. 실험결과, 케이블의 길이가 길어짐에 따라 과도전압의 최대값이 증가하였으며 50m 케이블에서 과도전압의 크기는 최대 3.3PU까지 측정되었다. 이러한 현상은 진행파의 반사와 투과에 의해 발생하며, 유도전동기의 인버터 구동시 케이블의 길이에 따른 과도전압의 영향을 고려하여 유도전동기의 절연을 설계해야 할 것이다.