• 제목/요약/키워드: Inverter drive

검색결과 752건 처리시간 0.026초

단전원 Gate Drive의 회로 설계에 관한 연구 (The Study on Gate Drive Circuit Design using Single Voltage)

  • 이상균;이재춘;이철웅;황민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2594-2596
    • /
    • 1999
  • Recently, white good market has interest with inverter product, which has merit to on/off type with respect to energy saving and noise. But, inverter product's cost is rising, because of adding inverter circuit component. To reduce cost, inverter gate drive trend is using HVIC which needs only single voltage. Also using HVIC, designer can compact PCB'size. This paper shows application technique and key point of designing HVIC

  • PDF

PWM 인버터의 전류파형 개선에 관한 연구 (Current Waveform Improvement of PWM Inverter)

  • 장석주;조상환;설승기
    • 대한전기학회논문지
    • /
    • 제39권3호
    • /
    • pp.273-280
    • /
    • 1990
  • To prevent the shoot-through phenomena in a PWM inverter, a short dead time is usually provided between a pair of switching transistors in the same leg of the inverter. In this approach, the amount of the dead time is designed to meet the worst case condition of the inverter transistors and the base drive elements. So, in normal cases, relatively large portion of the dead time is unnecessary and it results in an undesirablecurrent waveform distortion and generates ripple torque on the motor shaft. In this paper, a new base drive method to remove the undesirable portion of the dead time is described. The method senses the transistor on/off states to interlock the other transistor of the leg without the external dead time. Also, for the transistors of large current rating, the Darlington drive circuit is combined to the proposed method and is tested to verify the effectiveness. The experimental results of the proposed method are described and compared with those of the conventional dead time method.

장제전류회로를 갖는 타려식 인버터를 이용한 유도적 성질 (Induction Motor Drive Using a Line Commutated Inverter with a Forced-Commutated Circuit)

  • 정연택;심재명
    • 대한전기학회논문지
    • /
    • 제41권6호
    • /
    • pp.588-599
    • /
    • 1992
  • This paper describes the variable speed drive of an induction motor by the line commutated inverter, which is operated in the forced commutation mode from start-up to operating point of load commutation. A novel forced-commutation circuit is proposed in this paper. The selection range of leading condenser to decide load commutation starting point is simulated by the sampling data of a general purpose IM and a high speed IM. The experiment to drive IM by a line commutated inverter with the proposed forced commutated circuits is performed. There was no problem in driving IM from standstill to starting point of load commutation by a line commutated inverter with forced commutation.

고속 SRM 구동 시스템 설계 (A Design of High Speed SRM Drive System)

  • 이주현;김봉철;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.110-113
    • /
    • 2005
  • This paper proposes high speed SRM drive system for blower with a new 4-level inverter and precise excitation position generator. For the high speed blower, a proper 12/8 SRM is designed and analyzed. In order to get a fast build-up and demagnetization of excitation a current, now 4-level inverter system is proposed. The proposed 4-level inverter has additional charge capacitor, power switch and diode in the conventional asymmetric converter. The charged high voltage is supplied to the phase winding for fast current build-up, and demagnetization current is charged to additional capacitor of 4-level inverter. In addition, a precise excitation position generator can reduce turn-on and turn-off angle error according to sampling period of digital control system. The proposed high speed SRM drive system is verified by computer simulation.

  • PDF

An examples of a 6-inch GTO inverter drive system applied for rougher mills

  • Kawasaki, Muneo;Okayama, Hideo;Koyama, Masato;Mitsuhashi, Masamichi;Masuda, Hiroyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.25-28
    • /
    • 1996
  • Recently, AC variable-speed motors are used for many steel rolling mill drive systems, because of their low maintenance and enhanced control performance. We have been applied GTO inverters for these AC motor drive systems since 1993. We have developed world largest 6-inch diameter GTO and large capacity 3-level GTO inverter up to 20000(kVA). As an example, in this paper, we describe the main circuit, system arrangement and control features of the 6-inches GTO inverters to drive rougher mills for hot strip mill of Pohang Iron & Steel Co., Ltd. The motor capacity is 6000(kW), and it's overload is 250(%).

  • PDF

Soft Switching Inverter with An Auxiliary Active Quasi-Resonant DC Link Snubber for AC Servo Motor Drive

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Park, Man-Kyu;Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.79-87
    • /
    • 2008
  • This paper presents a simple circuit topology of the auxiliary active quasi-resonant DC link snubber-assisted three phase voltage source soft-switching inverter for small scale PM motor drive applications. The pulse processing drive circuit interface and its soft-switching operation are discussed from an experimental point of view. Moreover, its conductive noise is measured and evaluated for electrical AC servo motor drive as compared with that of the conventional hard switching inverter.

인버터 모터 드라이브 시스템을 위한 새로운 1200V High Side Driver (Advanced 1200V High Side Driver for Inverter Motor Drive System)

  • 송기남;오원희;최진규;이은영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.487-488
    • /
    • 2015
  • New inverter motor drive systems consume 30%~50% less energy compared to existing motor drive systems. For inverter motor drive systems, the development of a 1200V high side driver is critical. This paper presents an advanced 1200V high side driver with low power consumption and high ruggedness. This solution implements a high voltage level shifter which consumes low power by adding a clamped VGS LDMOS driver to the conventional short pulse generator. Moreover, this paper proposes a highly rugged 1200V LDMOS which improves SOA by limiting the hole current. This paper could be applied to smart power modules used for HVAC (heating, ventilation, and airconditioning) and industrial inverters. Consequently, this paper will provide design engineers with an understanding of how they can make a significant contribution to worldwide energy savings.

  • PDF

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

BLDCM 구동 인버터의 실시간 데이터를 이용한 고장진단 (Fault Diagnosis based on Real-Time Data of the inverter system for BLDCM drive)

  • 김광헌;배동관
    • 조명전기설비학회논문지
    • /
    • 제12권2호
    • /
    • pp.29-37
    • /
    • 1998
  • 이 논문은 브리시리스 직류전동기의 구동 인버터의 실시간 데이터를 이용한 고장진단에 관한 것이다. 구동 인버터의 고장유형을 파악하여 주요 고장증세별로 분류하고, 고장결과를 예측하여 ASCL로 시뮬레이션함으로써 지식 베이스로 구성하였다. 구동 인버터에 대해 실시간으로 감시된 데이터는 전문가 시스템의 추론기관에서 시뮬레이션된 지식베이스와 비교하게 된다. 고장이 발생하면, 운전을 중지시킨 후, 전문가 추론을 함으로써 고장원인을 진단한다. 이로써 구동 인버터에 대해 전문적인 지식을 갖고 있지 않는 사용자에게, 고장원인 제거 및 수리대책에 관한 전문가의 지식을 신속히 제공하는 것이다.

  • PDF

견인전동기 가변속 운전을 위한 인버터의 PWM 방법 및 패턴 절환기법에 관한 연구 (A Study on the PWM Strategy and Gear Changing Techniques of an Inverter for Variable Speed Drives on Traction Motors)

  • 서영민;박영진;홍순찬
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권11호
    • /
    • pp.646-654
    • /
    • 1999
  • This paper deals with PWM patterns for harmonic reduction in inverter fed traction motors and the gear changing techniques for the variable speed drive of traction motor. GTOs are used as switching device of inverter because traction motor is a large load. To derive PWM rattern which can minimize the harmonics with the limited switching frequency, the output current and torque characteristic of SPWM and SHE PWM was analyzed. GTO inverter used for traction motor drive includes harmonics in the output current and torque by the limitation of switching frequency. However, the hybrid PWM method that adopt SPWM in the range of low frequency and SHE PWM in upper frequency range can achieve less harmonic characteristics in GTO inverters. If the traction motor is driven in variable speed by the proposed PWM pattern, 7 times of gear changing is needed. At the instant of the mode change, magnetic flux and torque may be altered and the large current flow. To reduce such an undesirable transient behavior, it is also presented the technique for the gear changing of inverter fed traction motor drive operated with the hybrid PWM. The results are verified by simulations and experiments.

  • PDF