• Title/Summary/Keyword: Inverter control

Search Result 2,698, Processing Time 0.031 seconds

A New Hybird Control Scheme Using Active-Clamped Class-E Inverter with Induction Heating Jar for High Power Applications

  • Lee, Dong-Yun;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.104-111
    • /
    • 2002
  • This paper presents a new hybrid control scheme using Active-Clamped Class-E(ACCE) inverter for the Induction Heating (IH) jar. The proposed hybrid control scheme has characteristics, which acts as class-E inverter at lower switch voltage and ACCE inverter at higher switch voltage than reference voltage of the main switch by feeding back voltage of the switch. The proposedv hybrid control scheme also has advantage of conventional ACCE inverter such as Zero-Voltage-Switch(ZVS) of the main switch and the reduced switch voltage due to clamping cricuit. Moreover, the proposed hybrid control method using ACCE inverter has higher output power than convenional control scheme since ACCE inverter operates like class-E inverter at low input voltage condition. The principles of the proposed control are explained in detail and the validity of the proposed control scheme is verifed through the several interesting simulated and experimental results.

Analysis of Output Characteristics for the Resonant DC Link Inverter Using PWM Inverter Modulation Methods (인버터 PWM 방식을 이용한 공진형 직류 링크 인버터의 출력 특성 해석)

  • 김윤호;윤병도;이병순
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.615-624
    • /
    • 1992
  • For the operation of the resonant DC link inverters, only limited number of modulation techniques such as the delta modulation and instantaneous current control techniques have been suggested. However, these modulation techniques have some limitations in practical operation. In this paper, the application of conventional inverter modulation techniques is suggested for the control of the resonant DC link inverter. The harmonic analysis results are presented. The results show that these modulation techniques offer good output characteristics similar to conventional inverter PWM techniques for the operation of the resonant DC link inverter. This implies that not only the delta modulation technique and instantaneous current control techniques but also various other modulation techniques can be applied to the operation of the resonant DC link inverter. This also indicates that open loop control as well as closed loop control can be used for the operation of the resonant inverter. The resonant DC link inverter with various modulation strategies is implemented using V-40 microprocessors.

  • PDF

EEFL Inverter Design with Program Control (프로그램 제어용 EEFL 인버터 설계)

  • Lee, Choong-Ho;Kim, Jung-Sam;Yoon, Dong-Han
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2008
  • Proposed EEFL inverter design method with Dimming control to use microprocessor. Reduce power loss using Energy Recovery method, and design inverter control program that use RS-232 communication. Also, low temperature driving time shortened 50% that use duty variable control.

  • PDF

The Characteristic of Inverter Control by Variation of Refrigeration Load and Outdoor Temperature on Industrial Cooler (외기온도와 부하변화에 따른 산업용 냉각기의 인버터제어 특성)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.150-155
    • /
    • 2014
  • This paper presents The performance analysis of inverter control type-industrial cooler with respect to refrigeration load and outdoor temperature. Aside from materials about simulations and foundation data regarding inverter control compressors, currently, data about commercial coolers with inverter control still lack information for performance comparison. Thus, in this paper, the experiments are done to see characteristics of condensation capacity, evaporation capacity, compressor power and COP with respect to outdoor temperature and load by using a commercial inverter control cooler model. As a result, COP difference of the inverter control cooler with respect to load is 30% at the outdoor temperature of $35^{\circ}C$, 29% at the outdoor temperature of $30^{\circ}C$, 34% at $25^{\circ}C$, respectively.

Development of the New Inverter Control System for TG Feedback a formula Control (Inverter Control System을 이용한 TG Feedback 제어기 개발)

  • Cho Hyoun-Seob;Min Jin-Kyoung;Song Young-Deog
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.191-193
    • /
    • 2005
  • In this paper new, inverter control system for TG feedback a formula Control was developed. The motor control system with TG feedback controller as an effect of load disturbance, it is very difficult to guarantee the robustness of control system. The function of the implementation we TG feedback type, and temperature scheme. The Inverter Control System approach is based on master-slave control concept. To show validity of the developed new inverter control system, several experiments are illustrated.

  • PDF

A Study on Nonlinear Control Strategy for Three-phase Voltage Source PWM DC/AC Inverter based on the PCH Model

  • Mu, Xiaobin;Wang, Jiuhe;Bao, Xueyu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.53-57
    • /
    • 2012
  • The mathematical model of a three-phase voltage source pulse-width modulation (PWM) DC/AC inverter is non-linear, and in view of the traditional linear control strategy it can not meet the requirements of designing a high-performance inverter. What's more, when the loads are not pure resistive loads, the inverter further requires that the controller possess high-performance. This paper proposes a nonlinear control strategy for the inverter called Passivity-based Control. We can alter the inverter model in three-phase abc coordinate to two-phase synchronous rotating dq coordinate for establishing the port-control Hamiltonian (PCH) model for this system. We can control the distribution of energy in the system to achieve the control aim. Simulation results show that the passivity-based control method can make this system possess a level of high-performance that is both robust and dynamic.

A study on the effect of inverter nonlinear characteristic on the flux estimation of an induction motor (인버터의 비선형 특성이 유도전동기의 자속 추정에 미치는 영향에 대한 연구)

  • Kim, Sang-Hoon;Kim, Tae-Suk
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.167-174
    • /
    • 2008
  • In this paper, the analysis on type effect of inverter output voltage distortion on the control of an induction motor is discussed. The inverter output voltage is distorted differently from the reference voltage owing to the inverter nonlinear characteristic. The inverter nonlinear characteristic results from the voltage drop, the inherent characteristic of the power semiconductor, and the dead time for preventing the short circuit of the inverter leg. This characteristic distorts the inverter output voltage and then, causes the motor flux estimation error. Although this characteristics do not significantly effect in the general-purpose induction motor control, but significantly effect on the low-speed operation of high performance motor control such as the sensorless vector control.

  • PDF

PWM Control of Reduced Switch Z-Source Inverter (스위치 저감형 Z-Source Inverter PWM 제어)

  • Kim, Seong-Hwan;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.53-57
    • /
    • 2019
  • In this paper, we propose a new Z-source inverter structure to reduce switching elements and PWM pulse control method. Z-network is connected between the inverter backplane and ground, rather than between the DC voltage and the inverter in an improved Z-source inverter. And the improved Z-source inverter has the advantages of limiting the capacitor inrush current and reducing the capacitor voltage stress. We have proposed a topology of a new type of switch-reduced improved Z-source inverter that reduces the number of switches from six to four in an improved Z-source inverter and developed a PWM control method suitable for the proposed topology. The characteristics and the performance of the proposed method were verified by using PSIM simulation.

The Control Technique of 3 Phase NPC PWM Inverter to control fixed Total Harmonic Distortion (종합 고조파 왜율 일정 제어를 위한 삼상 NPC PWM 인버어터의 제어 기법)

  • Song, Eon-Bin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.565-567
    • /
    • 1994
  • This paper presents a software based NPC PWM inverter control technique to eliminate the harmonics in the output waveforms of inverter. The proposed control technique is able to keep down total harmonic distortion and significantly improve the performance of the inverter. In the control node where the frequency ratio is 36 and the modulation index is $1.2\sim2.0$, the proposed inverter has been operated wi thin 5% Total Harmonic Distortion.

  • PDF

Instantaneous Current Control for Parallel Inverter with a Current Share Bus (전류공유버스를 이용한 병렬 인버터 순시 제어기 설계)

  • 이창석;김시경
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.90-94
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employes active and reactive power control or frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employes a instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Futhermore, the proposed control scheme is verified through the simulation in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF