• 제목/요약/키워드: Inverter Program

검색결과 118건 처리시간 0.032초

고효율 인버터 프로그램의 수용가 반응 조사분석 (Survey and Analysis of Customer Behavior on High Efficiency Inverter Program)

  • 박종진;곽미애;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.674-676
    • /
    • 2004
  • This paper analyzes the customer behavior on high efficiency inverter program from three angles, that is, rebates, electricity rates and the cost of measures. After deregulation, the importance of high efficiency DSM programs has been more and more increased. Especially, the inverter program is one of the most high efficiency DSM program, so it is needed the policy to promote the inverter program diffusion.

  • PDF

8200대 전기기관차 보조전원장치의 특성에 관한 연구 (A Study for Characteristics of the Auxiliary Inverter in the 8200 Electric Locomotive)

  • 김진용;이상준;최종묵;강승욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.237-244
    • /
    • 2005
  • The Auxiliary Inverter supply the power to Loads of Electric Locomotive. The Auxiliary Inverter have three characteristics. First, The Auxiliary Inverter is VVVF(variable voltage variable frequency) inverter. And, the output voltage is AC $0^{\sim}440V$. Second, The Auxiliary Inverter is controled all operations by CCU(Center Control Unit). Last, The Auxiliary Inverter have the SIBMON program. This program easily displays most of all status of auxiliary inverter.

  • PDF

프로그램 제어용 EEFL 인버터 설계 (EEFL Inverter Design with Program Control)

  • 이충호;김정삼;윤동한
    • 한국정보전자통신기술학회논문지
    • /
    • 제1권1호
    • /
    • pp.79-84
    • /
    • 2008
  • 마이크로프로세서를 이용하여 Dimming Control이 있는 EEFL inverter 설계방법을 제안하였다. Energy Recovery방법을 사용하여 전력손실을 줄이고 RS-232 통신을 이용한 Inverter 제어용 프로그램을 개발하였다. 또한 Duty 변환 방식을 이용하여 저온구동 시간을 약50%정도 단축하였다.

  • PDF

고효율 인버터 프로그램의 지원금 수준에 대한 수용가 반응 조사분석 (Survey and Analysis of Customer Behavior on Rebate levels of High Efficiency Inverter Programs)

  • 박종진;곽미애
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.273-275
    • /
    • 2007
  • This paper analyzes the customer behavior on high efficiency inverter program in terms of rebate levels. The importance of high efficiency DSM programs has been more and more increased after deregulation. Especially, the inverter program is one of the most high efficiency DSM programs, so this paper presents proper rebate levels in terms of both participants and non-participants to promote diffusion of the inverters.

  • PDF

Electricity Energy Savings Evaluation of Inverter DSM Program based on the Measurement and Estimation

  • Kim, Hoi-Cheol;Kim, In-Soo;Park, Jong-Bae;Shin, Joong-Rin
    • KIEE International Transactions on Power Engineering
    • /
    • 제11A권4호
    • /
    • pp.45-50
    • /
    • 2001
  • The impact evaluation of a DSM program is a very important issue since the results are used to determine the sustainability of a program. In general. to estimate the impacts of a DSM program it is required to measure the electricity usage changes before and after a program. Since the measurement-based approaches cost highly, most of the conventional evaluations are based on the average figures. However estimation of the average-based impacts can lead to both distorted results of over/under estimation of kW and kWh savings and non-optimal DSM planning. In this paper, we have developed a new multi-point measurement approach which can evaluate kW and kWh savings of a DSM program more exactly. To do this, the saving rate and operating rate are defined and set as the function of load factor of a customer, and these rates are incorporated with the conventional diffusion function of Bass to project the future impacts of a DSM program. The case study is performed on the inverter program of Korea by using the suggested approach.

  • PDF

인버터 DSM 프로그램 보급과 시장 전망 (Evaluation of Inverter DSM Program in KEPCO and Market Diffusion)

  • 이학주;박재덕;김용진;이수목
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.370-371
    • /
    • 2006
  • The electric demand increase, financial need for new power plant constructions and environmental problem have led to search for more efficient energy Production and energy conservation technology. To minimize the construction of power plants and reduce total power consumption include installation of inverters to motors used for pumps and fans. However, the high price of inverters is the biggest obstacle to their wide use. Accordingly, to maximize the effect of energy saving by the expanded use of inverters, governmental economic support as ell as the analysis of energy saving effect. his paper presents he present state analysis of inverter DSM program and propose he improvement for activation of inverter DSM program.

  • PDF

인버터 DSM 프로그램의 경제성평가 (Economic Analysis of Inverter DSM Program for Inverter)

  • 이학주;권성철;최병윤;이승윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.521-523
    • /
    • 2001
  • The electric demand increase, financial need for new power plant constructions and environmental problem have led to search for more efficient energy production and energy conservation technology. To minimize the construction of power plants and reduce total power consumption include installation of inverters to motors used for pumps and fans. However, the high price of Inverters is the biggest obstacle to their wide use. Accordingly, to maximize the effect of energy saving by the expanded use of inverters, governmental economic support as well as the analysis of energy saving effect. This paper presents the cost-effectiveness analysis for DSM program evaluation and case study to analyze inverter DSM program.

  • PDF

압전 변압기 이용 Full-Bridge형 인버터 설계 (Design of the full-Bridge type Piezoelectric Inverter)

  • 임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.78-81
    • /
    • 2000
  • The backlight inverter used in a laptop computer is investigated in this paper. It has been difficult for the electromagnetic transformer in the inverter to have a high efficiency and compact profile. In this study the piezoelectric transformer(PT) is used to reduce the loss and volume compared to the standard electromagnetic transformer. Comparison with the experimental inverter with the PT has been shown to validated the simulation program using the equivalent circuit model of the PT. A simple dimming control circuit was experimentally demonstrated and shown to have broad control.

  • PDF

유도가열 부하를 갖는 인버터 회로의 해석에 관한 연구 (The Analysis of Inverter Circuit with Induction Heating Load)

  • 노희석;권경안;양우종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.424-427
    • /
    • 1995
  • This paper proposes an analysis of an inverter circuit which has an induction heating load. Two major kinds of the inverters are E-class quasi resonant and half-bridge type. The analyses of induction heating load property and operation property are introduced. A simulation program which implements those properties is also introduced. The results of the simulation program are verified through experimental results.

  • PDF

Development of the Dynamic Simulation Program of a Multi-Inverter Heat Pump under Frosting Conditions

  • Park Byung-Duck;Lee Joo-Dong;Chung Baik-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.113-122
    • /
    • 2004
  • In case of heat exchangers operating under frosting condition, the thermal resistance and the air-side pressure loss increase with a growth of frost layer. In this paper, a transient characteristic prediction model of the heat transfer for a multi-inverter heat pump with frosting on its surface was presented by taking into account the change of the fin efficiency due to the growth of the frost layer. This dynamic simulation program was developed for a basic air conditioning system composed of an evaporator, a condenser, a compressor, a linear electronic expansion valve, and a bypass circuit. The theoretical model was derived from measured heat transfer and mass transfer coefficients. We also considered that the heat transfer performance was only affected by the decrease of wind flow area. The calculated results were compared with the experimental results for frosting conditions.