• Title/Summary/Keyword: Inverter Application

Search Result 423, Processing Time 0.026 seconds

Start-up Control of LLC Resonant Inverter for Microwave Oven Application (전자레인지용 LLC 공진형 인버터의 기동 제어)

  • Kang, Kyelyong;Kim, Heung-Geun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.463-468
    • /
    • 2017
  • One of the most critical part for magnetron driving in microwave oven is start-up control. For this, switching frequency of resonant inverter should be carefully controlled in order to supply sufficient power to the filament of the magnetron and to prevent rectifier diode from destruction caused by the excessive voltage across them. This paper proposes a novel start-up control strategy for LLC resonant inverter for microwave oven considering the non-oscillation mode time and the magnetron voltage during the start-up process. The validity of the proposed method is verified through the experiment with 1,200W microwave oven using LLC resonant inverter.

Improvement of Welding Performance of Flash bull Welder by on Inverter Controlled Technology (인버터 제어방식을 이용한 Flash butt 용접기의 용접성능 향상)

  • 이왕하;박상국;이성희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • For the improvement of welding performance, high-efficiency inverter system was designed and applied that system to the conventional large scale Flashbutt welder. The inverter systems are consists of full bridge PWM power control system and DSP controller. This inverter system has increased switching frequency of power control system of Flashbutt welder. For the test of application effects, we compared an our inverter control system with a conventional thyristor control system. In the results, we confirmed that our system has decreased the welding spatter amouts and improved welding performance.

Design of Traction Motor with consideration of Inverter Characteristics & Products Trend for Subway Train Application (인버터 특성을 고려한 견인전동기 설계와 제품동향)

  • Kim Jong-Ku;Kwon Jung-Lock;Kim Kun-Woong;Lee Jung-Il
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.459-463
    • /
    • 2001
  • Since recent inverters are formed IGBT VVVF inverter its switching speed has been increased relative to the conventional inverters and the motor design based on the switching surge voltage at the inverter output is very important factor. Therefore, motor and inverter should be designed to have the optimal characteristics by considering the mutually limited conditions. On this research the design technology characteristics for inverter driving traction moor is compared to the products in Korea and the analysis is performed. Thus, it is intend to re-estimate the technology level and introduce the products by HHI, which is driving on Seoul subway line 6 since December, 2000.

  • PDF

Harmonic analysis for Inverter related with PCR (PCR과 인버터의 결합에 의한 고조파 해석)

  • Kang, Seol-Moog;Koo, Bon-Ho;Kwen, Wu-Hyen;Kim, Soo-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.746-748
    • /
    • 1987
  • A volocity and an efficiency of an induction motor are lower than those of a DC motor. But in the control, the utility of an AC motor is more enlarged with the development of inverter. But unfortunately, in using the induction motor, it include a lot of harmonics because of switching of semi-conductor devices(SCR or Tr) in the inverter. In PCR, as the change of a firing angle $\alpha$, harmonics are changed. Hence, in this thesis analyze the harmonics and provide the region of it's application when PWM and 6-step applied to inverter. Of course, frequencies of inverter changed. Especially, in PWM a carrier ratio is changed.

  • PDF

A Novel Switched Capacitor Lossless Inductors Quasi-Resonant Snubber Assisted ZCS PWM High Frequency Series Load Resonant Inverter

  • Fathy, Khairy;Kang, Tae-Kyung;Kwon, Soon-Kurl;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.169-171
    • /
    • 2005
  • In this paper, a novel type of auxiliary switched capacitor assisted edge resonant soft switching PWM series load resonant high frequency inverter with two auxiliary edge resonant lossless inductor snubbers is proposed for small consumer induction heating appliances. The operation principle of this high frequency inverter is described using the switching mode equivalent circuits. The practical effectiveness of the newly proposed soft switching inverter are discussed as compared with the conventional soft switching high frequency inverters based on simulation and experimental results from an application point of view.

  • PDF

Control Method and Application of PWM Inverter for Active Silencer (능동소음기를 위한 PWM 인버터의 제어기법 및 적용)

  • Lee, Seung-Yo;Choe, Gyu-Ha;Kang, Jung-Yu;Jang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.311-314
    • /
    • 1995
  • PWM(Pulse-Width Modulation) is frequently used as control method for inverter. In control of active silencer studied presently, PWM control method can be applied. This paper presents its possibility. As operating source of loudspeaker, inverter is used instead of audio amplifier and PWM controller controls the inverter to make canceling sound. This paper presents that active silencer of inverter-type using the PWM control method makes the canceling sound to acoustic noise and cancels the acoustic noise.

  • PDF

SiC Motor Drive for Elevator System (엘리베이터 시스템을 위한 SiC 권상기 드라이브)

  • Gwon, Jin-Su;Moon, Seok-Hwan;Kim, Ju-Chan;Lee, Joon-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2019
  • With the recent emphasis on the importance of energy conservation, studies on high-efficiency elevator systems are being continuously conducted. Therefore, pulse width modulation converters are commonly used in traction drives on elevator systems. Wide bandgap devices have been increasingly commercialized, and their application to power conversion systems, such as renewable and energy storage system, has been gradually increasing. In this study, a SiC inverter for an elevator traction drive is investigated. In particular, an inverter is designed to minimize stray and parasitic inductance. Input and output filters are designed by considering switching frequency. The designed SiC inverter reduces volume by approximately 32% compared with that of a Si inverter, and power converter efficiency is over 98.8%.

The Implementation of the Solar Inverter Monitoring System using an AJAX (AJAX를 이용한 태양광 인버터의 모니터링 시스템 구현)

  • Kwon, Hyo-Sang;Yang, Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1915-1922
    • /
    • 2012
  • In this paper, the Solar Inverter will be monitored by using the AJAX(Asynchronous JavaScript and XML). AJAX is the one of the technologies that can make the RIA(Rich Internet Application) with DHTML(Dynamic Hyper Text Makeup Language) and other java script technology. By using this, a strong application program that is comparable to the general application program can be made. With an existing data-processing technique, the request and response of data can't be processed dynamically on the same page. However, real-time monitoring of data and operation statuses can be confirmed by using the AJAX an asynchronous method of communication. Also without changing the page, the amount of data transmission used the AJAX with significantly small amounts of data to build a Solar Inverter monitoring system that is able to efficiently handle management and monitoring, operating all functions within one page.

Development of the CO2 Inverter Welding Controller for Compensation of Voltage Loss (전압손실 보상용 CO2 인버터 용접기 콘트롤라 개발)

  • Bae, Jong-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.4
    • /
    • pp.54-60
    • /
    • 2005
  • In a $CO_2$ inverter welding machine, stable arcs can be generated and a welding performance that is a goal of welding can be improved when stable electric power with a low voltage and a high current is supplied to a electrode that is the secondary part (output load terminal) and the base metal. For such a stable power supply, therefore, the AC arc welding machine, the thyristor welder, and the inverter welder have been developed in order according to development of the power electronics techniques. Up to now, the thyristor welding machine is still broadly used but the application volume is gradually reduced by development of the inverter welder. Because the welding performance of the inverter welder is very good and the weight and size of the welder is remarkably light and small. The final goal of this research is to develop the voltage loss compensator that is a drawback of the inverter welder and improve the welding performance using the developed compensator.

  • PDF

The Control of load Commutated Current Source Inverter for Induction Motor Drive (유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御))

  • Chung, Y.T.;Sim, J.M.;Lee, S.Y.;Soh, Y.C.;Lee, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF