• Title/Summary/Keyword: Inverse power law

Search Result 54, Processing Time 0.033 seconds

Clamp Type-dependent HCF Life Estimation of the Overhead Cable for Distribution Grids (고정 방식 차이에 따른 배전 가공전선의 고주기피로 수명 특성 비교 평가)

  • Lee, Dooyoung;Jung, Jinseung;Kim, Youngdae;Bang, Jiye
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.241-248
    • /
    • 2021
  • High cycle fatigue life for the cables with two different types of clamps is estimated comparatively through acceleration testing. The high cycle fatigue fracture of overhead lines is caused mainly by the aeolian vibration which is induced by vortex shedding. It is necessary to manage the integrity of cables continuedly considering that the aeolian vibration is unavoidable since it occurs in steady and relatively low wind velocity. Two types of clamps which are largely used for overhead lines of the distribution grids are selected and failure data are obtained by step stress testing with a electrodynamic shaker with them. The inverse power law is assumed to describe the stress-life relationship and the fatigue limit at any specified life is supposed to follow Weibull distribution. The life of the cable is defined as the number of cycles to the time that one of strands is completely broken. Finally, the fatigue limits of the cables with two clamp types are estimated at the reference life of 500 Mcycles and compared each other based on a bending vibration amplitude.

The Optiomun Treatment Conditions an the Estimation of Life in the Interface between Epoxy/EPDM (Epoxy/EPDM계면의 최적처리 조건과 수명 예측)

  • Oh, Jae-Han;Bae, Duck-Kweon;Choi, Woon-Shik;Lee, Kyong-Sob
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1978-1980
    • /
    • 2000
  • Because the interfaces between two different materials are the weak-link in the underground power transmission systems, they affects the stability of insulation systems. In this paper, Epoxy/EPDM interface is selected and investigated the optimum condition by variation of interfacial conditions such as roughness of surface, spreading of oils, interfacial pressure and temperature. The breakdown times under the constant voltage below the breakdown voltage were also gamed. The breakdown voltage at the after laying time equivalent to is calculated by the V-t characteristic and the inverse power law. When this is done. the characteristic life exponent n is used and the long time breakdown voltage can be evaluated.

  • PDF

A study on development of program for estimation the Lifetime of insulating materials (절연재료의 수명예측을 위한 프로그램개발에 관한 연구)

  • 박성민;배덕권;정인재;박우현;이기식;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.699-702
    • /
    • 2000
  • Today, electrical machine is being large capacitor and EHV(Extra High Voltage) of power equipment is a need of high reliability of insulating matetials. Therefore, it is a need of fixed appraisement of lifetime to used data of breakdown. This paper studied a development of the program for estimation the lifetime of insullating materials and the long-time breakdown voltage by experimentation. The estimation program is based on the "Inverse Power Law", defined V$\^$n/t is constant. After gaining the life exponent n, it is mapping the long-time breakdown voltages. On the base of life exponent, the estimation of lifetime and usefulness of the insulation systems are possible, furthermore easy calculation is possible.

  • PDF

Analysis of reliability test results of low-pass filter assembly (저역필터 어셈블리에 대한 신뢰성시험 결과의 해석)

  • Baik, Jaiwook
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.45-51
    • /
    • 2014
  • Thermal shock tests at two stress levels were performed to see the life (cycles) of LPF ASSY (low pass filter assembly) at normal stress level. In this case Coffin-Manson relationship is generally used to describe the relationship between the temperature difference and the life, together with the Weibull distribution describing the life at each stress level. So for given data Coffin-Manson is fitted to predict the life at normal stress level. However, different types of models are appropriate for this type of test. Hence, a more appropriate model such as General log-linear model which can also incorporate the duration at the highest and lowest temperatures and acceleration time will be introduced.

Nonparametric Estimation for Ramp Stress Tests with Stress Bound under Intermittent Inspection (단속적 검사에서 스트레스한계를 가지는 램프스트레스시험을 위한 비모수적 추정)

  • Lee Nak-Young;Ahn Ung-Hwan
    • Journal of Korean Society for Quality Management
    • /
    • v.32 no.4
    • /
    • pp.208-219
    • /
    • 2004
  • This paper considers a nonparametric estimation of lifetime distribution for ramp stress tests with stress bound under intermittent inspection. The test items are inspected only at specified time points an⊂1 so the collected observations are grouped data. Under the cumulative exposure model, two nonparametric estimation methods of estimating the lifetime distribution at use condition stress are proposed for the situation which the time transformation function relating stress to lifetime is a type of the inverse power law. Each of items is initially put on test under ramp stress and then survivors are put on test under constant stress, where all failures in the Inspection interval are assumed to occur at the midi)oint or the endpoint of that interval. Two proposed estimators of quantile from grouped data consisting of the number of items failed in each inspection interval are numerically compared with the maximum likelihood estimator(MLE) based on Weibull distribution.

Optimum Progressive-Stress Accelerated Life Test (증가하는 스트레스에서의 최적가속수명시험)

  • Yun, Won-Young;Jung, Sung-Gi
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.19 no.2
    • /
    • pp.15-21
    • /
    • 1993
  • This paper considers the optimal design of accelerated life test in which the stress is linearly increased. It discusses the special case when the life distribution under constant stress follows an exponential distribution and the accelerated equation satisfies the inverse power law. It is assumed that cumulative damage is linear, that is, the remaining life of test units depends only on the current cumulative fraction failed and current stress(cumulative exposure model). The optimization criterion is the asymptotic variance of the maximum likelihood estimator of the log mean life at a design stress. The optimal increasing rate is obtained to minimize the asymptotic variance. Table of sensitivity analysis is given for the prior estimators of model parameters.

  • PDF

와이불 분포에 대한 최대 시험 스트레스를 최소화하기 위한 최적가속수명시험 설계

  • 배석주;강창욱
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.678-681
    • /
    • 1995
  • 가속수명시험은 매우 신뢰성이 높은 제품의 수명분포에 대한 정보를 빨리 얻기 위해 사용된다. 이때, 빠른 시간안에 정보를 얻기 위해 제품의 사용조건보다 높은 스트레스 즉 온도, 압력, 전압, 진동등을 사용하여 시험을 하게 되는데 최대 시험 스트레스는 미리 실험자에 의해 선택되게 된다. 그러나 주어진 최대 시험 스트레스가 스트레스의 한계범위를 벗어나는 경우에는 사용조건과 다른 고장구조가 발생할 수 있고, 이로 인하여 편의가 큰 신뢰수명의 추정치를 얻을 수 있다. 기존의 논문에서는 실험자의 경험 또는 사전시험을 통해 미리 설정된 최대 시험 스트레스하에서 제품수명의 표준편차를 최소화하기 위한 최적가속수명시험 설계방법을 제시하였다. 그러나 본 논문에서는 와이불 분포에서 1) 사용조건에서의 수명추정치의 분산 .leq. k, 2) 스트레스의 범위를 벗어나지 않는 최대 시험 스트레스의 최소값을 구하는 설계방법을 제시하고, 또한 구한 스트레스에서의 수명 및 최소 시험 스트레스에서 시험되어야 할 제품의 수를 추정한다. 이때, 사용전압에서의 수명을 계산하기 위하여 inverse power law 모형을 도입하였으며, type I censoring 방법을 사용하여 수명 데이타들은 모든 제품이 고장나기 전에 분석될 수 있도록 하였다.

  • PDF

Theoretical Study of Gamma-ray Pulsars

  • Song, Yuzhe;Cheng, Kwong Sang;Takata, Jumpei
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.69-73
    • /
    • 2016
  • We use the non-stationary three dimensional two-layer outer gap model to explain gamma-ray emissions from a pulsar magnetosphere. We found out that for some pulsars like the Geminga pulsar, it was hard to explain emissions above a level of around 1 GeV. We then developed the model into a non-stationary model. In this model we assigned a power-law distribution to one or more of the spectral parameters proposed in the previous model and calculated the weighted phase-averaged spectrum. Though this model is suitable for some pulsars, it still cannot explain the high energy emission of the Geminga pulsar. An Inverse-Compton Scattering component between the primary particles and the radio photons in the outer magnetosphere was introduced into the model, and this component produced a sufficient number of GeV photons in the spectrum of the Geminga pulsar.

Weibull Step-Stress Type-I Model Predict the Lifetime of Device (소자의 수명 예측을 위한 Weibull Step-Stress Type-I Model)

  • 정재성;오영환
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.6
    • /
    • pp.67-74
    • /
    • 1995
  • This paper proposes the step-stress type-I censoring model for analyzing the data of accelerated life test and reducing the time of accelerated life test. In order to obtain the data of accelerated life test, the step-stress accelerated life test was run with voltage stress to CMOS Hex Buffer. The Weibull distribution, the Inverse-power-law model and Maximum likelihood method were used. The iterative procedure using modified-quasi-linearization method is applied to solve the nonlinear equation. The proposed Weibull step-stress type-I censoring model exactly estimases the life time of units, while reducting the time of accelerated life test and the equipments of test.

  • PDF

Electrical Lifetime Estimation of a Relay by Accelerated Life Test (가속수명시험을 이용한 릴레이의 전기적 수명예측)

  • Kim, Jae-Jung;Chang, Seog-Weon;Son, Young-Kap
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.5
    • /
    • pp.430-436
    • /
    • 2008
  • This paper proposes a way to predict electrical lifetime of a relay using Accelerated Life Testings (ALTs). The relay of interest mounting on printed circuit boards is usually under an inrush current stress. The inrush current is generated and accelerated through controlling a lamp switching device in the ALT. We find that the dominant failure mechanism under high levels of inrush current would be contact welding in the contact surface of the relay and the contact welding process is accelerated according to increase in inrush current. The electrical lifetime model based on Inverse Power Law in term of inrush current is proposed, and parameters characterizing relay's lifetime distribution are statistically estimated using ALTA 6 PRO software.