• Title/Summary/Keyword: Intravenous(IV) injection

Search Result 66, Processing Time 0.024 seconds

The Relationship of Pain, Depression and Anxiety which Patients Recognize on Intravenous Injection - Focus on Pain Relating Factors - (정맥주사 투여 시 대상자가 인지하는 통증, 우울 및 불안과의 관계 - 통증 관련요인을 중심으로 -)

  • Kim, Hee-Jeong;Chaung, Seung-Kyo;Kim, Kyung-Hee;Kang, Kyoung-Ah
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.14 no.3
    • /
    • pp.306-314
    • /
    • 2007
  • Purpose: The purpose of this study was to identify factors that have an influence on the pain which patients recognize when receiving an intravenous injection. Method: Participants were 111 patients who were admitting to C University Hospital. The collected data were analyzed using the SPSS 11.0 program. Results: For the participants, factors related to administration of medication were the following: Phlebitis scale, who administers the IV injection, failure to complete the IV injection, explaination of the IV injection and rate of injection. Level of pain, depression and anxiety in the participants was as follows: Pain ($4.86{\pm}2.09$), depression ($35.76{\pm}9.91$), anxiety ($32.34{\pm}8.87$). There were positive correlations between pain and depression (r= .437, p< .000), between pain and anxiety (r= .478, p< .000), and between depression and anxiety (r= .544, p< .000). Conclusion: Such findings provide new insights into the dynamic relationships between depression, anxiety and pain which patients recognize when having an intravenous injection. Further studies should be conducted to establish the causal relation between depression, anxiety and pain and to determine appropriate nursing interventions.

  • PDF

Comparison of Training Effectiveness for IV Injections: Intravenous (IV) Arm Model versus Computer Simulator (마네킹 모델과 컴퓨터 시뮬레이터를 이용한 정맥주사 실습교육의 효과 비교)

  • Hwang, Juhee;Kim, Hyunjung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.21 no.3
    • /
    • pp.302-310
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the effectiveness of training using an intravenous (IV) arm model versus a computer simulator for IV injections. Method: Study was a quasi-experimental study conducted with 106 nursing students. Participants were divided into two groups: the IV Arm Group using a mannequin arm model (control group) and the Computer Simulator Group using the Virtual IV demonstration (experimental group). Theoretical lectures and video presentations on IV injections were given to both groups. Each group went through the training practice using the IV arm or computer simulator. After the completion of training, questionnaires were given to the students to evaluate their learning attitudes and experiences, self-confidence in IV injection, and satisfaction with the training materials. Results: Student satisfaction with the training materials including the reality, usefulness, and educational effects showed notable differences between the two groups with the Computer Simulator group reporting more positive effects that the IV Arm group. However, there was no statistical difference between the two groups in the categories of learning attitude, learning experience, or self-confidence. Conclusion: While there was a differences in strengths and weaknesses of the two methods, both methods should be considered for practice and further study needs to be done on educational effectiveness.

A Study of Influencing Factors in the Effectiveness of Vascular and Hepatic Parenchyma Enhancement During Intravenous Injection of Contrast Medium (경정맥 조영제 주입시 혈관 및 간실질의 조영증강에 영향을 미치는 외부적 인자에 관한 연구)

  • Han Dong-Hyun;Chang Kun-Jo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.30 no.1
    • /
    • pp.131-142
    • /
    • 2004
  • In this study, when intravenous contrast medium was injected in spiral CT study, the effects of injection volume, injection rate, injection mode, location and lumen of IV catheter on enhancement of contrast medium in aorta, portal vein and liver parenchym

  • PDF

Automatic Flow Control and Network Monitoring of IV Injection (자동 IV 주사 유량 자동 제어 및 네트워크 모니터링)

  • Kim, Jin-Nam;Kwon, Won-Tae;Lee, Kang-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.161-166
    • /
    • 2012
  • Intravenous (IV) injection is widely used to supply Ringer solution directly into a vein in hospital. Generally, a passive injection method has been used, which causes the inconsistent flow rate of fluid and inappropriate control of injection time by a patient. It leads to an unnecessary nurse's overwork and decrement of IV injection's effect. To solve these problems, flow control infusion pumps have been developed. But because of relatively heavy weight and high price, its usage has been limited. In the present study, a new automatic IV injection system is developed. It is installed with a small pressing mechanism driven by a small electric motor to regulate the flow rate by pressing tube. Proportional integral derivative (PID) feedback control algorithm is applied to control the electric motor. The system is smaller in size and uses lower power than the existing commercial product. The newly developed system is also installed with networking capability, which enables monitoring the status of several automatic IV injection system at the same time.

A Study on the Comparison of Detected Vein Images by NIR LED Quantity of Vein Detector (정맥검출기의 NIR LED 수량에 따른 검출된 정맥 이미지 비교에 관한 연구)

  • Jae-Hyun, Jo;Jin-Hyoung, Jeong;Seung-Hun, Kim;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Intravenous injection is the most frequent invasive treatment for inpatients and is widely used for parenteral nutrition administration and blood products, and more than 1 billion procedures are used for peripheral catheter insertion, blood collection, and other IV therapy per year. Intravenous injection is one of the difficult procedures to be performed only by trained nurses with intravenous injection training, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Accordingly, studies on auxiliary equipment capable of visualizing the vein structure of the back of the hand or arm are being published to reduce errors during intravenous injection. This study is a study on the performance difference according to the number of LEDs irradiating the 850nm wavelength band on a vein detector that visualizes the vein during intravenous injection. Four LED PCBs were produced by attaching NIR filters to CCD and CMOS camera lenses irradiated on the skin to acquire images, sharpen the acquired images using image processing algorithms, and project the sharpened images onto the skin. After that, each PCB was attached to the front end of the vein detector to detect the vein image and create a performance comparison questionnaire based on the vein image obtained for performance evaluation. The survey was conducted on 20 nurses working at K Hospital.

Single-dose Toxicity of Guseonwangdo-go Glucose 5% Intravenous Injection in a Rat Model

  • Jo, Su-jeong;Choi, Young-doo;Jung, Chan-yung;Kim, Kap-sung;Lee, Seung-deok
    • Journal of Pharmacopuncture
    • /
    • v.18 no.3
    • /
    • pp.57-62
    • /
    • 2015
  • Objectives: The purpose of this study was to examine the single-dose intravenous toxicity of Guseonwangdo-go glucose 5% pharmacopuncture (GWG5). Methods: Forty Sprague-Dawley rats were divided into four groups of five males and five females per group: an intravenous (IV) injection of 1.0 mL of normal saline solution per animal was administered to the control group; IV injections of 0.1, 0.5, and 1.0 mL of GWG5 per animal were administered to the experimental groups (G: 0.1, G: 0.5, and G: 1.0). Observation of clinical signs and body weight measurements were carried out for 14 days following the injections. At the end of the observation period, hematological, biochemical, and histopathological tests, as well as necropsy examinations, were performed on the injected parts. Results: No mortalities or adverse clinical signs were observed in any of the groups. The body weights of all groups continuously increased. In the hematological and the biochemical tests, females in G-0.1 had minimal changes, but those changes were not dose dependent. On necropsy examination, no abnormalities were observed. In the histopathological test, focal inflammatory cell infiltrations were observed in two female rats, one in the control group and one in G-1.0. Also, one female rat in the control group had an epidermis crust. These changes were concluded to have been caused by the insertion of the needle into a vein. Conclusion: The above findings suggest that the lethal dose of GWG5 administered via IV injection is more than 1.0 mL per animal in both male and female rats. Further studies are needed to establish more detailed evidence of its toxicity.

The Effect of cutaneous Stimulation and Distraction on IV Injection Pain of Chemotherapy Patients (피부자극과 관심전환이 항암제 정맥주사 삽입시 통증감소에 미치는 영향)

  • 박정숙
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.2
    • /
    • pp.303-318
    • /
    • 1998
  • Cutaneous stimulation and distraction are independent nursing interventions used in various painful conditions, which is explained by gate control theory. This study was aimed at identifying the effect of cutaneous stimulation, distraction and combination of cutaneous stimulation and distraction on the reduction of intravenous injection pain levels of chemotherapy patients. Repeated measurement post test research design was used for one group. Fifty-three cancer patients who received intravenous chemotherapy regulary in outpatient injection rooms of D medical center and Y medical center in Taegu were studied from June 23, 1997 to July 12, 1997. First the intravenous injection pain level of the control period was measured. Second, the intravenous injection pain level of the experimental period using cutaneous stimulation was measured. Third, the intravenous injection pain level of the experimental period using distraction was messured. Fourth, the intravenous injection pain level of the experimental period using a combination of cutaneous stimulation and distraction was measured. The instruments used for this study were a visual analogue pain scale as subjective pain measurement and an objective pain behavior checklist. Analysis of data was done by use of repeated measure ANOVA, bonferni, t-test, and F-test. The results of this study were summerized as follows : 1) The first hypothesis that the subjective pain score of intraveneous injection pain in the experimental period with cutaneous stimulation will be lower than in the control period was rejected. 2) The second hypothesis that the objective pain behavior score of intravenous injection pain in the experimental period with cutaneous stimulation will be lower than in the control period was accepted(F=24.23, p=0.0001, Bornferni p<.05). 3) The third hypothesis that the subjective pain score of intraveneous injection pain in the experimental period with distraction will be lower than in the control period was rejected. 4) The fourth hypothesis that the objective pain score of intravenous injection pain in the experimental period with distraction will be lower than in the control period was accepted(F=24.23, p=0.0001, Bornferni p<.05). 5) The fifth hypothesis that the subjective pain score of intravenous injection pain in the experimental period with combination of cutaneous stimulation and distraction will be lower than in the control period was accepted(F=3.04, p=0.031, Bonferni p<.05). 6) The sixth hypothesis that the objective pain score of intravenous injection pain in the experimental period with combination of cutaneous stimulation and distraction will be lower than in the control period was accepted(F=24.23, p=0.0001, Bonferni p<.05).

  • PDF

A Study on the Nurse's Recognition and Performance in Intravenous Therapy Management (간호사의 정맥주사 관리에 대한 인식과 수행에 관한 연구)

  • Kim Myung-Hee;Kim Youn-Hwa
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.207-224
    • /
    • 1998
  • The purposes of this study were to identify nurse's recognition and performance and to represent the factors of hindrance in the IV therapy management. The subjects were 420 nurses who worked at five general hospitals in Pusan. Tha data were collected using a questionnaire and the period of data collection was from January 1 to January 31, 1998. The instrument for this study was made by author oneself on the basis of guidelines Simmons et al', CDC' Stanley' and Kurdi' guideline, Cllinical Nurse's Association' that consist of 68 items for 5 fields ; pre-injection, just before-injection, needle-injection, during injection, post-injection field. Cron-bach Alpha coefficient of recognition and performance in the IV therapy management was .93 and .87. The datas were analized by a SPSS program using frequency, percent, paired t-test, t-test and oneway ANOVA. The results obtained were as follows : 1. The mean score of recognition in IV therapy management was significantly higher than that of performance(t=5.86, P<.001). 2. The items of lower than mean score of each fields in performance were the identification of drugs, hands washing, patient teaching about medication, disinfectional methods of the injection site and the rubber stopper in bottle, the use of disposable gloves, mask and eye goggles at the chemotherapy preparation, use of tape and armboard, changing the IV tubing, labeling the dressing over the injection site, observation and recordings of patient's condition after medication and confirmation of the needle length at the needle removal. 3. The factors of hindrance in IV therapy were 'having no time', 'insufficiency of goods', 'unknowing of methods', 'no disadvantage', and 'factors of doctor's doing'. The most important factor was 'have no time', especially item of hands washing. The other factors of hindrance showed high frequency in the following items ; 'insufficiency of goods' in the use of disposable gloves, mask and eye goggles at the chemotherapy preparation, 'unknowing of methods' in the certification of drugs compatibility, 'no disadvantage' in the labeling the dressing over the injection site, and 'factors of doctor's doing' in the changing the subclavian catheter dressing and checking the glucose level during the TPN infusion. In conclusion, there is necessity of educational program which can improve the nurse's knowledge of drugs, disinfection methods, comfort of patient and recordings in IV therapy management and alternative plan which are political and financial aids such as setting up the sink, giving of paper towels and necessary goods in the IV therapy for reducing the factors of hindrance for IV therapy management.

  • PDF

A Study on the Development of Intravenous Injection Management Application for EMR System Interworking (EMR 시스템 연동 정맥주사 관리 애플리케이션 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Seung-Hun, Kim;Won-yeop, Park;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.506-514
    • /
    • 2022
  • This paper is about developing an intravenous injection management system that can provide nurses with information related to intravenous injection in real-time to compensate for possible instability factors during intravenous injection. The intravenous injection management system consists of an app-based user S/W and a web-based administrator S/W. User S/W is implemented to provide users with the ability to identify patients who need intravenous injection through smartphones, tablet PCs, and nursing PDAs, recognize information codes given to patients, and enter and share treatment contents and treatment items after intravenous injection. As a result of intravenous injection treatment uploaded through the user app, the manager S/W can check the records of intravenous injection treatment items, perform user management functions, emergency notification registration and management functions, and data upload functions. The implemented system has not yet been tested on the EMR system used in the actual hospital. Therefore, through further research, S/W will be optimized and actual environmental application tests will be conducted through cooperation with hospitals.

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.