• 제목/요약/키워드: Intra-class coefficients

검색결과 46건 처리시간 0.021초

Three-Dimensional Evaluation of Skeletal Stability following Surgery-First Orthognathic Approach: Validation of a Simple and Effective Method

  • Nabil M. Mansour;Mohamed E. Abdelshaheed;Ahmed H. El-Sabbagh;Ahmed M. Bahaa El-Din;Young Chul Kim;Jong-Woo Choi
    • Archives of Plastic Surgery
    • /
    • 제50권3호
    • /
    • pp.254-263
    • /
    • 2023
  • Background The three-dimensional (3D) evaluation of skeletal stability after orthognathic surgery is a time-consuming and complex procedure. The complexity increases further when evaluating the surgery-first orthognathic approach (SFOA). Herein, we propose and validate a simple time-saving method of 3D analysis using a single software, demonstrating high accuracy and repeatability. Methods This retrospective cohort study included 12 patients with skeletal class 3 malocclusion who underwent bimaxillary surgery without any presurgical orthodontics. Computed tomography (CT)/cone-beam CT images of each patient were obtained at three different time points (preoperation [T0], immediately postoperation [T1], and 1 year after surgery [T2]) and reconstructed into 3D images. After automatic surface-based alignment of the three models based on the anterior cranial base, five easily located anatomical landmarks were defined to each model. A set of angular and linear measurements were automatically calculated and used to define the amount of movement (T1-T0) and the amount of relapse (T2-T1). To evaluate the reproducibility, two independent observers processed all the cases, One of them repeated the steps after 2 weeks to assess intraobserver variability. Intraclass correlation coefficients (ICCs) were calculated at a 95% confidence interval. Time required for evaluating each case was recorded. Results Both the intra- and interobserver variability showed high ICC values (more than 0.95) with low measurement variations (mean linear variations: 0.18 mm; mean angular variations: 0.25 degree). Time needed for the evaluation process ranged from 3 to 5 minutes. Conclusion This approach is time-saving, semiautomatic, and easy to learn and can be used to effectively evaluate stability after SFOA.

The Reliability and Validity of a Portable Hand-held Spirometer for the Measurement of Various Lung Functions in Healthy Adults

  • Merve Nur Uygun;Jun-Min Ann;Byeong-Hyeon Woo;Hyeon-Myeong Park;Ha-Im Kim;Dae-Sung Park;In-Beom Jeong
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권2호
    • /
    • pp.179-186
    • /
    • 2024
  • Objective: This study aims to assess the reliability and validity of the new hand-held spirometer as a potential substitute for traditional pulmonary function testing (PFT) devices. Design: Cross-sectional study. Methods: In this study, thirty healthy adults underwent spirometry using both the new hand-held spirometer and the MIR spirometer, which is a standard PFT device. Parameters including peak expiratory flow (PEF), forced expiratory volume in one second (FEV1), and forced vital capacity (FVC) were measured and analyzed for validity and reliability. Inter-rater reliability and validity were evaluated through 95% limits of agreement (LOA) and intraclass correlation coefficients (ICC). Statistical analyses, including the Bland-Altman plots and the ICC, were utilized to assess agreement between the two devices. Results: The new hand-held spirometer exhibited a good agreement with intra-class coefficient (ICC [2,1]) ranging 0.762 to 0.956 and 95% LOA of -1.94 to 1.80 when compared with MIR. The test-retest reliability of the hand-held spirometer analyzed using - ICC [2,1] demonstrated a good level of consistency (ICC [2,1] =0.849-0.934). Conclusions: In conclusion, the study aimed to assess the potential of the new hand-held spirometer as a viable alternative to traditional PFT devices, with a specific focus on its reliability and validity in spirometric measurements. The new hand-held spirometer exhibited good test-retest reliability across all measured variables, suggesting its potential as a valid and reliable tool for simultaneous PFT measurements.

Comparison of Novel Telemonitoring System Using the Single-lead Electrocardiogram Patch With Conventional Telemetry System

  • Soonil Kwon;Eue-Keun Choi;So-Ryoung Lee;Seil Oh;Hee-Seok Song;Young-Shin Lee;Sang-Jin Han;Hong Euy Lim
    • Korean Circulation Journal
    • /
    • 제54권3호
    • /
    • pp.140-153
    • /
    • 2024
  • Background and Objectives: Although a single-lead electrocardiogram (ECG) patch may provide advantages for detecting arrhythmias in outpatient settings owing to user convenience, its comparative effectiveness for real-time telemonitoring in inpatient settings remains unclear. We aimed to compare a novel telemonitoring system using a single-lead ECG patch with a conventional telemonitoring system in an inpatient setting. Methods: This was a single-center, prospective cohort study. Patients admitted to the cardiology unit for arrhythmia treatment who required a wireless ECG telemonitoring system were enrolled. A single-lead ECG patch and conventional telemetry were applied simultaneously in hospitalized patients for over 24 hours for real-time telemonitoring. The basic ECG parameters, arrhythmia episodes, and signal loss or noise were compared between the 2 systems. Results: Eighty participants (mean age 62±10 years, 76.3% male) were enrolled. The three most common indications for ECG telemonitoring were atrial fibrillation (66.3%), sick sinus syndrome (12.5%), and atrioventricular block (10.0%). The intra-class correlation coefficients for detecting the number of total beats, atrial and ventricular premature complexes, maximal, average, and minimal heart rates, and pauses were all over 0.9 with p values for reliability <0.001. Compared to a conventional system, a novel system demonstrated significantly lower signal noise (median 0.3% [0.1-1.6%] vs. 2.4% [1.4-3.7%], p<0.001) and fewer episodes of signal loss (median 22 [2-53] vs. 64 [22-112] episodes, p=0.002). Conclusions: The novel telemonitoring system using a single-lead ECG patch offers performance comparable to that of a conventional system while significantly reducing signal loss and noise.

Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone loss

  • Hangmiao Lyu;Li Xu;Huimin Ma;Jianxia Hou;Xiaoxia Wang;Yong Wang;Yijiao Zhao;Weiran Li;Xiaotong Li
    • 대한치과교정학회지
    • /
    • 제53권2호
    • /
    • pp.77-88
    • /
    • 2023
  • Objective: To develop a method for generating three-dimensional (3D) digital models of the periodontal ligament (PDL) using 3D cone-beam computed tomography (CBCT) reconstruction and to evaluate the accuracy and agreement of the 3D PDL models in the measurement of periodontal bone loss. Methods: CBCT data collected from four patients with skeletal Class III malocclusion prior to periodontal surgery were reconstructed at three voxel sizes (0.2 mm, 0.25 mm, and 0.3 mm), and 3D tooth and alveolar bone models were generated to obtain digital PDL models for the maxillary and mandibular anterior teeth. Linear measurements of the alveolar bone crest obtained during periodontal surgery were compared with the digital measurements for assessment of the accuracy of the digital models. The agreement and reliability of the digital PDL models were analyzed using intra- and interexaminer correlation coefficients and Bland-Altman plots. Results: Digital models of the maxillary and mandibular anterior teeth, PDL, and alveolar bone of the four patients were successfully established. Relative to the intraoperative measurements, linear measurements obtained from the 3D digital models were accurate, and there were no significant differences among different voxel sizes at different sites. High diagnostic coincidence rates were found for the maxillary anterior teeth. The digital models showed high intra- and interexaminer agreement. Conclusions: Digital PDL models generated by 3D CBCT reconstruction can provide accurate and useful information regarding the alveolar crest morphology and facilitate reproducible measurements. This could assist clinicians in the evaluation of periodontal prognosis and establishment of an appropriate orthodontic treatment plan.

Reliability and Data Integration of Duplicated Test Results Using Two Bioelectrical Impedence Analysis Machines in the Korean Genome and Epidemiology Study

  • Park, Bo-Young;Yang, Jae-Jeong;Yang, Ji-Hyun;Kim, Ji-Min;Cho, Lisa-Y.;Kang, Dae-Hee;Shin, Chol;Hong, Young-Seoub;Choi, Bo-Youl;Kim, Sung-Soo;Park, Man-Suck;Park, Sue-K.
    • Journal of Preventive Medicine and Public Health
    • /
    • 제43권6호
    • /
    • pp.479-485
    • /
    • 2010
  • Objectives: The Korean Genome and Epidemiology Study (KoGES), a multicenter-based multi-cohort study, has collected information on body composition using two different bioelectrical impedence analysis (BIA) machines. The aim of the study was to evaluate the possibility of whether the test values measured from different BIA machines can be integrated through statistical adjustment algorithm under excellent inter-rater reliability. Methods: We selected two centers to measure inter-rater reliability of the two BIA machines. We set up the two machines side by side and measured subjects' body compositions between October and December 2007. Duplicated test values of 848 subjects were collected. Pearson and intra-class correlation coefficients for inter-rater reliability were estimated using results from the two machines. To detect the feasibility for data integration, we constructed statistical compensation models using linear regression models with residual analysis and R-square values. Results: All correlation coefficients indicated excellent reliability except mineral mass. However, models using only duplicated body composition values for data integration were not feasible due to relatively low $R^2$ values of 0.8 for mineral mass and target weight. To integrate body composition data, models adjusted for four empirical variables that were age, sex, weight and height were most ideal (all $R^2$ > 0.9). Conclusions: The test values measured with the two BIA machines in the KoGES have excellent reliability for the nine body composition values. Based on reliability, values can be integrated through algorithmic statistical adjustment using regression equations that includes age, sex, weight, and height.

한국 인구에서 NeuroQuant와 DeepBrain에서 측정된 뇌 용적의 정상규준 백분위수 비교: 두개골 형태와의 연관성 (Comparison of Normative Percentiles of Brain Volume Obtained from NeuroQuant vs. DeepBrain in the Korean Population: Correlation with Cranial Shape)

  • 양미현;김은희;최은선;고홍석
    • 대한영상의학회지
    • /
    • 제84권5호
    • /
    • pp.1080-1090
    • /
    • 2023
  • 목적 이 연구의 목적은 한국 인구에서 NeuroQuant (이하 NQ)와 DeepBrain (이하 DB)에서 측정된 뇌 용적과 정상규준 백분위수를 비교하고, 두개골 형태와의 연관성을 확인하는 것이다. 대상과 방법 이 연구는 구조적 뇌 이상이 없는 163명의 한국인을 대상으로 NQ와 DB에서 측정된 뇌 용적과 정상규준 백분위수를 비교하고, 두개골 형태와의 연관성을 확인한 후향적 연구이다. 급내상관계수분석과 선형분석의 통계학적 분석을 시행하였다. 결과 정상규준 백분위수는 시상(90.8 vs. 63.3 percentile), 피각(90.0 vs. 60.0 percentile), 그리고 두정엽(80.1 vs. 74.1 percentile)에서 NQ가 DB보다 더 큰 것으로 나타났고, 후두엽(18.4 vs. 68.5 percentile)은 DB가 NQ보다 큰 것으로 나타났으며, 특히 후두엽의 경우 두개골 형태와의 비교 연구에서 유의미한 연관성을 보였고, 두개골의 전후 방향의 길이와 비례하고 상하방향의 길이와는 반비례했다. 결론 NQ와 DB에서 얻은 정상규준 백분위는 각 뇌 영역마다 유의미한 차이를 보였고, 그 차이는 한국 인구의 두개골 형태와 유의미한 관계가 있었다.