• 제목/요약/키워드: Intra-class coefficients

검색결과 46건 처리시간 0.021초

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • 대한물리치료과학회지
    • /
    • 제27권3호
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

Multilevel Analysis of the Relationship Between Prescribing Institutions and Medication Adherence Among Patients With Hypertension and Diabetes in Korea

  • Haryeom Ghang;Juhyang Lee
    • Journal of Preventive Medicine and Public Health
    • /
    • 제56권6호
    • /
    • pp.504-514
    • /
    • 2023
  • Objectives: This study investigated the relationship between prescribing institutions and medication adherence among patients newly diagnosed with hypertension and diabetes. Methods: This study investigated patients with new prescriptions for hypertension and diabetes in Korea in 2019 with using data collected from general health screenings. A multilevel logistic regression model was applied to explore the relationship between patients' first prescribing institution and their medication adherence, defined as a medication possession ratio (MPR) over 80%. Results: The overall adherence rates were 53.7% and 56.0% among patients with hypertension and diabetes, respectively. The intra-class correlation coefficients were 13.2% for hypertension and 13.8% for diabetes (p<0.001), implying that the first prescribing institution had a significant role in medication adherence. With clinics as the reference group, all other types of hospitals showed an odds ratio (OR) less than 1.00, with the lowest for tertiary hospitals (OR, 0.30 for hypertension; 0.45 for diabetes), and the next lowest in health screening specialized clinics (OR, 0.51 for hypertension; 0.46 for diabetes). Among individual-level variables, female sex, older age, higher insurance premium level, and residing in cities were positively associated with adherence in both the hypertension and diabetes samples. Conclusions: This study showed that the prescribing institution had a significant relationship with medication adherence. When the first prescribing institution was a clinic, newly diagnosed patients were more likely to adhere to their medication. These results highlight the important role played by primary care institutions in managing mild chronic diseases.

Reliability of a Newly Developed Tool to Assess and Classify Work-related Stress (TAWS-16) for Indian Workforce

  • Gautham Melur Sukumar;Runalika Roy;Mariamma Philip;Gururaj Gopalkrishna
    • Journal of Preventive Medicine and Public Health
    • /
    • 제56권5호
    • /
    • pp.407-412
    • /
    • 2023
  • Objectives: Work stress is associated with non-communicable diseases, increased healthcare costs, and decreased work productivity among employees in the information technology sector. There is a need for regular work-stress screening among employees using valid and reliable tools. The Tool to Assess and Classify Work Stress (TAWS-16) was developed to overcome limitations in existing stress assessment tools in India. This study aimed to test the reliability of TAWS-16 in a sample of managerial-supervisory employees. Methods: This observational reliability study included data from 62 employees. Test-retest and inter-method reliability were investigated using a TAWS-16 web application and interview by telephone, respectively. Kappa values and intra-class correlation coefficients were calculated. Internal consistency was assessed through Cronbach's alpha. Results: For both test-retest and inter-method reliability, the agreement for both work-related factors and symptoms suggestive of work stress exceeded 80%, and all kappa values were 0.40 or higher. Cronbach's alpha for test-retest and inter-method reliability was 0.983 and 0.941, respectively. Conclusions: TAWS-16 demonstrated acceptable reliability. It measured stressors, coping abilities, and psychosomatic symptoms associated with work stress. We recommend using TAWS-16 to holistically identify work stress among employees during periodical health check-ups in India.

한국어판 측두하악장애 연구진단기준 (RDC/TMD) 설문지의 신뢰도에 관한 연구 (Reliability of the Korean Version of Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD))

  • 손병진;박민우;박지운;정성창;정진우
    • Journal of Oral Medicine and Pain
    • /
    • 제33권4호
    • /
    • pp.323-338
    • /
    • 2008
  • 한국어판 측두하악장애 연구진단기준(RDC/TMD) 설문지의 신뢰도를 분석하기 위하여 서울대학교 치과병원 구강내과에 내원한 154명의 턱관절장애 환자들(남자 31명, 여자 123명)에게 한국어판 RDC/TMD 설문지를 작성하게 하였다. 검사-재검사 신뢰도는 동일한 피검자에게 1주 내지 2주 간격으로 같은 설문지를 작성토록 하였다. 설문지의 검사-재검사가 완료되기 전까지는 환자에게 어떠한 치료도 제공되지 않았다. 첫번째 검사로 본 통증강도(pain intensity), 장애점수(disability score), 악기능장애(jaw disability) 및 심리사회적 상태(psychosocial status)의 내적 일관성(internal consistency)의 신뢰도는 크론바흐-알파(Cronbach’s alpha) 계수로 각각 0.92, 0.94, 0.68, 0.94 였다. 검사-재검사 신뢰도의 각 설문항목별 상관계수는 0.40에서 0.94까지의 범위로 나타났으며, 각각의 세부 항목별 등급내 상관계수(intra-class correlation coefficient; ICC)는 0.81에서 0.93의 범위로 나타났다. 만성통증척도(Graded Chronic Pain)의 검사-재검사 신뢰도계수는 0.63이었다. 한국어판 RDC/TMD 설문지는 좋은 신뢰도를 보였으며, 한국인의 측두하악장애 환자들에서 심리사회적측면을 분석하는데 유용하게 사용될 수 있다.

자기기록식 3일간의 24시간 회상법의 신뢰도 연구 -서울지역 중년 자원자를 대상으로- (Reproducibility of Nutrient Intake Estimated by Three-Day 24-Hour Dietary Recall of Middle-Aged Subjects for 6 Month Intervals)

  • 이미숙;우미경;김성애;오세인;곽충실
    • 대한지역사회영양학회지
    • /
    • 제8권4호
    • /
    • pp.603-609
    • /
    • 2003
  • This study examined the reproducibility of nutrient intakes estimated by the 24-hour recall method in a prospective cohort study (Longitudinal study of aging and health monitoring of Korean elderly) of middle-aged volunteer subjects (42 males and 49 females) in the Seoul area. The three-day 24-hour recall was administered twice at an interval of approximately 6 months. The first data were collected and a corrective procedure was performed by interviewing of the subjects and a trained dietitian. The second data were collected by mail from the subjects without the performance of any corrective procedure. The mean age of the subjects was 53.5 $\pm$ 9.6 for the males and 52.2 $\pm$ 8.9 for the females. The subjects who had above college education were 95% in the case of the males and 60% in the case of the females. The characteristics of the male subjects in this study were that they were highly educated and held professional jobs and were from the middle or upper class. Comparing the first and second 24-hour recall data, the second data showed relatively lower intakes of all nutrients, except vitamin A, vitamin Bi and cholesterol. There was no difference in the nutrients of the first and the second data with respect to vitamin A, vitamin B$_1$ and cholesterol in the males and calcium, iron, sodium, vitamin A, vitamin B$_1$, vitamin B$_2$ and cholesterol in the females. This data may indicate that the 24 hour retail method without a dietitian's help may result in lower reporting of the subject's intakes. The men had a tendency to remember less than the women. Pearson's correlation coefficients with unadjusted nutrient intakes values were ranged from 0.24 to 0.66. When energy intake was adjusted, there was a slight increase (from 0.26 to 0.71). Intra-class correlation coefficients with nutrient-unadjusted values ranged from 0.22 to 0.66, and the energy-adjusted values were ranged from 0.23 to 0.69. The weighted Kappa statistical values ranged from 0.10 to 0.40. On the average,46.3% of the subjects who were found in the lowest quartile of the nutrient intake levels based on the first 24-hour recall, were in the lowest quartile based on the second 24-hour recall. Therefore, there was a low reproducibility between the first and the second 24-hour recall. We should examine the factors influencing low reproducibility. Also, strategies should be developed to maximize the reliability of the assessment, with regard to portion-size training and telephone validation. (Korean J Community Nutrition 8(4) : 603∼609, 2003)

Development of a Wearable Inertial Sensor-based Gait Analysis Device Using Machine Learning Algorithms -Validity of the Temporal Gait Parameter in Healthy Young Adults-

  • Seol, Pyong-Wha;Yoo, Heung-Jong;Choi, Yoon-Chul;Shin, Min-Yong;Choo, Kwang-Jae;Kim, Kyoung-Shin;Baek, Seung-Yoon;Lee, Yong-Woo;Song, Chang-Ho
    • PNF and Movement
    • /
    • 제18권2호
    • /
    • pp.287-296
    • /
    • 2020
  • Purpose: The study aims were to develop a wearable inertial sensor-based gait analysis device that uses machine learning algorithms, and to validate this novel device using temporal gait parameters. Methods: Thirty-four healthy young participants (22 male, 12 female, aged 25.76 years) with no musculoskeletal disorders were asked to walk at three different speeds. As they walked, data were simultaneously collected by a motion capture system and inertial measurement units (Reseed®). The data were sent to a machine learning algorithm adapted to the wearable inertial sensor-based gait analysis device. The validity of the newly developed instrument was assessed by comparing it to data from the motion capture system. Results: At normal speeds, intra-class correlation coefficients (ICC) for the temporal gait parameters were excellent (ICC [2, 1], 0.99~0.99), and coefficient of variation (CV) error values were insignificant for all gait parameters (0.31~1.08%). At slow speeds, ICCs for the temporal gait parameters were excellent (ICC [2, 1], 0.98~0.99), and CV error values were very small for all gait parameters (0.33~1.24%). At the fastest speeds, ICCs for temporal gait parameters were excellent (ICC [2, 1], 0.86~0.99) but less impressive than for the other speeds. CV error values were small for all gait parameters (0.17~5.58%). Conclusion: These results confirm that both the wearable inertial sensor-based gait analysis device and the machine learning algorithms have strong concurrent validity for temporal variables. On that basis, this novel wearable device is likely to prove useful for establishing temporal gait parameters while assessing gait.

Reliability of the Korean Version of Tampa Scale for Kinesiophobia for Temporomandibular Disorders

  • Park, In Hee;Jang, Ji Hee;Chung, Jin Woo
    • Journal of Oral Medicine and Pain
    • /
    • 제43권2호
    • /
    • pp.34-40
    • /
    • 2018
  • Purpose: The aim of this study was to translate the original English version of tampa scale for kinesiophobia for temporomandibular disorders (TSK-TMDs) for cultural equivalency into Korean language and to evaluate the reliability of the Korean version of the TSK-TMD among symptom free subjects. Methods: The original version of TSK-TMD was translated and cross-culturally adapted following international guidelines. A total 90 subjects (50 women, 40 men) were participated to fill out the questionnaire. The internal consistency and test-retest reliability with a one- or two-week time interval were evaluated. Results: The internal consistency of TSK-TMD of the original and the modified 12-item TSK-TMD were 0.866, and 0.858, respectively using the Cronbach's alpha coefficient. And the internal consistency of activity avoidance (AA) and somatic focus (SF) subscale were 0.838 and 0.807 assessed with Cronbach's alpha indicating excellent reliability. Test-retest reliability of the original TSK-TMD measured by the intra-class correlation coefficient (ICC) was 0.764, and coefficients value of the 12-question TSK-TMD was 0.752. Test-retest reliability of AA subscale was 0.722 and SF subscale was 0.677 measured by ICC. Conclusions: The Korean version of the TSK-TMD questionnaire was found to be a reliable instrument and successfully translated to Korean language. There are no significant differences between overall and modified version of TSK-TMD. It can be used as a valuable instrument for the analyses of the psychosocial aspects of the TMD patients in Korea.

A study on the clinical usefulness, validity, and test-retest reliability of the Spirokit, a device that combines the pulmonary function test and respiratory muscle strength test

  • Kim, Byeong-Soo;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권2호
    • /
    • pp.120-130
    • /
    • 2020
  • Objective: This study was conducted to identify the clinical usefulness, validity, and reliability of the Spirokit, a device that combines the pulmonary function test (PFT) and respiratory muscle strength (RMS) test. Design: Cross-sectional study. Methods: Forty young adults (male: 23, female: 17) participated in a PFT and a RMS test. The concurrent validity for pulmonary function was assessed by comparing data obtained from MicroQuark and the Spirokit and the agreements between the MicroRPM and the Spirokit for RMS were compared. The test-retest reliability of the Spirokit was determined by comparing data obtained from the first and second sessions. The test and retest were performed at the same time after one day for the PFT and RMS test. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Results: The Spirokit showed a high agreement intra class coefficient (ICC [2, 1]): 0.978-0.999, 95% limits of agreements (95% LOA): -0.798 to 0.847 with MicroQuark. It also showed a high level of concordance ICC (2, 1): 0.992 to 0.993, 95% LOA: -9.313 to 11.169 with MicroRPM. The test-retest reliability of the Spirokit was analyzed using ICC (2, 1), and showed a high level of reliability (ICC [2,1]=0.960 to 0.998). Standard error of measurement % (SEM%) was 0.12% to 3.39%, and minimum detectable change% (MDC%) was 0.02% to 3.79%, indicating high level of reliability. Conclusions: The Spirokit is a device with high validity and reliability that can be used to simultaneously measure PFT and RMS tests.

Validity of the Wii Balance Board for Evaluation of Medial Patellar Luxation in Small Sized Dog

  • Lee, Shinho;Lee, Joo-Myoung;Park, Hyunjung;Cha, Yuri;Cheong, Jongtae
    • 한국임상수의학회지
    • /
    • 제36권6호
    • /
    • pp.297-300
    • /
    • 2019
  • Wii® balance board (WBB) is a device that can measure and record body sway. This study was conducted to evaluate the reliability of WBB in small sized dog as inexpensive, portable and convenient tool. The center of pressure path length (CPPL) and 95% confidence ellipse area (Area 95) were evaluated with only two plates of WBB. The parameters were evaluated between no load (0 kg) and mass group (0.25-4 kg on each one plate). 23 dogs (2.3-7.3 kg) were evaluated for with hindlimb standing for 10 seconds. The mass group showed a significant value in comparison to the no load during the measurement. And intra-class correlation coefficients (ICCs) between CPPL and Area 95 revealed very high both mass and dog group. In the evaluation of medial patellar luxation (MPL) as a diagnostic tool, 80 dogs with MPL and 23 non-affected dogs were used. In studies of CPPL and Area 95, significant differences were found between non-affected and MPL groups for 10 and 30 seconds, respectively. The WBB can be used as a valid tool for evaluating hind limb standing balance and can be useful as an objective tool to present clinical results in small sized dog with MPL.

Reliability of joint angle during sit-to-stand movements in persons with stroke using portable gait analysis system based wearable sensors

  • An, Jung-Ae;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권3호
    • /
    • pp.146-151
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the test-retest reliability and concurrent validity of the joint angle of the lower extremities during sit-to-stand movements with wearable sensors based on a portable gait analysis system (PGAS), and the results were compared with a analysis system (MAS) to predict the clinical potential of it. Design: Cross-sectional study. Methods: Sixteen persons with stroke (9 males, 7 females) participated in this study. All subjects had the MAS and designed PGS applied simultaneously and eight sensor units of designed PGAS were placed in a position to avoid overlap with the reflexive markers from MAS. The initial position of the subjects was 90º of hip, knee, and ankle joint flexion while sitting on a chair that was armless and backless. The height of the chair was adjusted to each individual. After each trial, the test administrator checked the quality of data from both systems that measured sit-to-stand for test-retest reliability and concurrent validity. Results: As a result, wearable sensor based designed PGAS and MAS demonstrated reasonable test-retest reliability for the assessment of joint angle in the lower extremities during sit-to-stand performance. The intra-class correlation coefficients (ICCs) for wearable sensor based designed PGAS showed an acceptable test-retest reliability, with ICCs ranging from 0.759 to 0.959. In contrast, the MAS showed good to excellent test-retest reliability, with ICCS ranging from 0.811 to 0.950. In concurrent validity, a significant positive relationship was observed between PGAS and MAS for variation of joint angle during sit-to-stand movements (p<0.01). A moderate to high relationship was found in the affected hip (r=0.665), unaffected hip (r=0.767), affected knee (r=0.876), unaffected knee (r=0.886), affected ankle (r=0.943) and unaffected ankle (r=0.823) respectively. Conclusions: The results of this study indicated that wearable sensor based designed PGAS showed acceptable test-retest reliability and concurrent validity in persons with stroke for sit-to-stand movements and wearable sensors based on developed PGAS may be a useful tool for clinical assessment of functional movement.