• Title/Summary/Keyword: Intra-Class Correlation Coefficient

Search Result 70, Processing Time 0.022 seconds

Validity and Reliability of an Oral Health Assessment Tool for Elderly in Long-Term Care Facilities (요양시설 노인을 위한 구강건강 평가 도구의 타당도와 신뢰도)

  • Kim, Na-Yeon;Bae, Hyun-Sook
    • Journal of Korean Dental Hygiene Science
    • /
    • v.4 no.1
    • /
    • pp.53-64
    • /
    • 2021
  • Background: The elderly in long-term care facilities tend to have a diminished oral health status, with a high prevalence of dental caries and periodontal disease, as reduced cognitive function, joint mobility, and gait ability hinder the performance of oral hygiene. To improve the oral health of the elderly at long-term care facilities, it is necessary to have precise guidelines for oral health care and assessment; however, such guidelines are not readily available. Therefore, the present study aimed to develop an oral care assessment tool with verified reliability and validity. Methods: The participants in this study were 100 elderly patients at a care facilities and 10 clinical dental hygienists. Collected data were analyzed using the descriptive statistics, content validity index, and inter-rater reliability, as well as the analyses of intra-class correlation coefficient. Results: After a review of relevant literature, a preliminary questionnaire comprised of seven questions related to the evaluation of oral health was formed. After revising and supplementing the questions through a content validity test, a total of nine questions were selected. Conclusion: The novel assessment tool developed for the present study is anticipated to allow analyses of the level of problems related to oral health care before routine and professional care. Moreover, regular oral health status check-ups will enable the early diagnosis and treatment of diseases.

Evaluations of the Accuracy and Reliability of Measurements Made on White Light Scanner-based Dental Digital Models (백색광 스캐너로 채득된 치과용 디지털모형의 정확도와 신뢰도 평가)

  • Kim, Ki-Baek;Kim, Jae-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.357-364
    • /
    • 2012
  • Dental scanner-based dental digital models have been developed that have the potential to replace conventional stone model. The aim of this study was examine the accuracy and reliability of measurements made on digital models. A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the white light scanner(Identica, korea). One examiner individually measured 6 parameters on the conventional model and the digital models on two occasions. The student's t-test for paired samples and intra-class correlation coefficient(ICC) were used for statistical analysis. At the intra-examiner reliability of measurement, ICC at the stone and digital models were 0.75 and 0.87. The mean difference between measurements made directly on the stone models and those made on the digital models was 0.11-0.23mm, and was statistically significant(P<0.05). These in vitro studies show that accuracy of the digital model is similar to that of the stone model. These results will have to be confirmed in further clinical studies.

Cultural Adaptation and Reliability Testing of Korean Version of the World Health Organization Disability Assessment Schedule 2.0 : 12-item versions (세계보건기구 기능제약평가목록 2.0 : 12항목-버전의 한글도구 개발과 신뢰도 검사)

  • Lee, Hae-Jung;Kim, Da-Jeong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.475-488
    • /
    • 2011
  • Purpose: The aims of the study were to develop and to establish reliability in Korean versions of World Health Organization Disability Assessment Schedule 2.0(KWHODAS 2.0): 12 item-self(12-self) and 12 item-interviewer(12-interviewer) versions. Methods: KWHODAS 2.0: 12-item versions were developed in idiomatic modern Korean with a process involving independent translation, synthesis of the translations, independent back translation, and review by an expert committee to achieve equivalence with the original English. 88 participants were included in the study. 33 of participants filled the 12-self version twice to examine test-retest reliability and 55 of participants were assessed simultaneously by four interviewers using the 12-interviewer version. Intra-rater reliability was evaluated using the intra-class correlation coefficient(ICC) and inter-rater reliability was evaluated using both the ICC and k statistic. Results: Test-retest reliability for the 12-self version was excellent with $ICC_{(2,1)}$ value ranged from 0.94(CI 0.88-0.98) to 0.96(CI 0.90-0.98). Inter-rater reliability for the 12-interviewer version showed excellent agreement with $ICC_{(2,1)}$ from 0.94(CI 0.91-0.96) to 1(CI 1.0-1.0). K value was observed from 0.95 to 1. Conclusion: KWHODAS 2.0: 12-self and 12-interviewer versions were successfully translated and both scales showed excellent reliability. It is now suitable for use in clinical and research applications.

Reproducibility of cone-beam computed tomographic measurements of bone plates and the interdental septum in the anterior mandible

  • Valerio, Claudia Scigliano;Alves, Claudia Assuncao e;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Purpose: This study aimed to introduce a novel method to evaluate the alveolar bone and interdental septum in the anterior mandible using cone-beam computed tomography (CBCT). Materials and Methods: Fifty-six CBCT scans from adult patients were selected. The CBCT scans were obtained before and after orthodontic treatment. The following measurements were taken: width of the alveolar bone and the interdental septum, height of the interdental septum, height of the bone plates, distance between the cementoenamel junction and marginal bone crests, and vertical positioning of the mandibular incisor, using the lingual plane as a reference. To test the reproducibility and the stability of the lingual plane, a triangle was traced in the anterior mandible. The intra-class correlation coefficient(ICC) was used to determine intra- and inter-examiner agreement. The paired Student t-test was used to evaluate the area of the triangle and the reproducibility of all measurements. Results: The ICC was excellent for the alveolar bone and dental measurements (0.9989 and 0.9977, respectively), as well as for the interdental septum (0.9987 and 0.9961, respectively). The area of the triangles showed stability in the lingual plane (P>0.05). For the alveolar bone, mandibular incisor, and interdental septum measurements, no statistically significant differences were found between the 2 examiners(P>0.05), confirming the technical reliability of the measurements. Conclusion: The method used in this study provides a valid and reproducible assessment of alveolar bone dimensions in the anterior mandible measured on CBCT images.

Korean Cultural Adaptation of WHODAS 2.0 (36-Item Version): Reliability and Linking to ICF

  • Song, Ju Min;Lee, Hae Jung
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.6
    • /
    • pp.246-255
    • /
    • 2018
  • Purpose: This study was to conduct a Korean cultural adaptation of the WHO disability assessment schedule (WHODAS) 2.0: 36-item version. Methods: An internationally standardized process of translation and cultural adaptation of an instrument was used to develop a Korean version of WHODAS 2.0: 36-item version. Linking each item into the International Classification of Functioning, Disability and Health (ICF) was also conducted in order to ensure the concepts in the translated instrument were compatible with ICF. All translated versions of the instrument, linking results and feedback from participants were used for the final adaptation of the Korean version of the instrument. The Korean version of the instrument was assessed twice on different occasions to examine Inter- and intra-rater reliability, and the intra-class correlation coefficient (ICC) was calculated. Results: Twelve participants were involved in the translation and linking process. Ninety-five volunteers were invited to participate to examine the reliability of the instrument. Fifty participants completed the self-rated version of the instrument and 45 finished the interviewer version. The Korean WHODAS 2.0: 36-item version was found to have excellent reliability: self-rated version and interviewer version reliability coefficients were ICC=0.92 and ICC=0.94, respectively. Thirty-four items of the translated instrument were to be linked to ICF categories. Some adaptation was made; details and a familiar example were added to help respondents answer the questions. Conclusion: The study results show that the adaptation of the 36-item version of WHODAS 2.0 to Korean was successful and the instrument is ready for use in testing its psychometric properties.

Reliability of the Korean Version of Tampa Scale for Kinesiophobia for Temporomandibular Disorders

  • Park, In Hee;Jang, Ji Hee;Chung, Jin Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.43 no.2
    • /
    • pp.34-40
    • /
    • 2018
  • Purpose: The aim of this study was to translate the original English version of tampa scale for kinesiophobia for temporomandibular disorders (TSK-TMDs) for cultural equivalency into Korean language and to evaluate the reliability of the Korean version of the TSK-TMD among symptom free subjects. Methods: The original version of TSK-TMD was translated and cross-culturally adapted following international guidelines. A total 90 subjects (50 women, 40 men) were participated to fill out the questionnaire. The internal consistency and test-retest reliability with a one- or two-week time interval were evaluated. Results: The internal consistency of TSK-TMD of the original and the modified 12-item TSK-TMD were 0.866, and 0.858, respectively using the Cronbach's alpha coefficient. And the internal consistency of activity avoidance (AA) and somatic focus (SF) subscale were 0.838 and 0.807 assessed with Cronbach's alpha indicating excellent reliability. Test-retest reliability of the original TSK-TMD measured by the intra-class correlation coefficient (ICC) was 0.764, and coefficients value of the 12-question TSK-TMD was 0.752. Test-retest reliability of AA subscale was 0.722 and SF subscale was 0.677 measured by ICC. Conclusions: The Korean version of the TSK-TMD questionnaire was found to be a reliable instrument and successfully translated to Korean language. There are no significant differences between overall and modified version of TSK-TMD. It can be used as a valuable instrument for the analyses of the psychosocial aspects of the TMD patients in Korea.

Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults

  • Jamal, Fatin Nabilah;Dzulkarnain, Ahmad Aidil Arafat;Shahrudin, Fatin Amira;Marzuki, Muhammad Nasrullah
    • Journal of Audiology & Otology
    • /
    • v.25 no.1
    • /
    • pp.14-21
    • /
    • 2021
  • Background and Objectives: There is growing interest in the use of the Level-specific (LS) CE-Chirp® stimulus in auditory brainstem response (ABR) due to its ability to produce prominent ABR waves with robust amplitudes. There are no known studies that investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus. The present study aims to investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus and compare its reliability with the ABR to standard click stimulus at multiple intensity levels in normal-hearing adults. Subjects and Methods: Eleven normal-hearing adults participated. The ABR test was repeated twice in the same clinical session and conducted again in another session. The ABR was acquired using both the click and LS CE-Chirp® stimuli at 4 presentation levels (80, 60, 40, and 20 dBnHL). Only the right ear was tested using the ipsilateral electrode montage. The reliability of the ABR findings (amplitudes and latencies) to the click and LS CE-Chirp® stimuli within the same clinical session and between the two clinical sessions was calculated using an intra-class correlation coefficient analysis (ICC). Results: The results showed a significant correlation of the ABR findings (amplitude and latencies) to both stimuli within the same session and between the clinical sessions. The ICC values ranged from moderate to excellent. Conclusions: The ABR results from both the LS CE-Chirp® and click stimuli were consistent and reliable over the two clinical sessions suggesting that both stimuli can be used for neurological diagnoses with the same reliability.

Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults

  • Jamal, Fatin Nabilah;Dzulkarnain, Ahmad Aidil Arafat;Shahrudin, Fatin Amira;Marzuki, Muhammad Nasrullah
    • Korean Journal of Audiology
    • /
    • v.25 no.1
    • /
    • pp.14-21
    • /
    • 2021
  • Background and Objectives: There is growing interest in the use of the Level-specific (LS) CE-Chirp® stimulus in auditory brainstem response (ABR) due to its ability to produce prominent ABR waves with robust amplitudes. There are no known studies that investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus. The present study aims to investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus and compare its reliability with the ABR to standard click stimulus at multiple intensity levels in normal-hearing adults. Subjects and Methods: Eleven normal-hearing adults participated. The ABR test was repeated twice in the same clinical session and conducted again in another session. The ABR was acquired using both the click and LS CE-Chirp® stimuli at 4 presentation levels (80, 60, 40, and 20 dBnHL). Only the right ear was tested using the ipsilateral electrode montage. The reliability of the ABR findings (amplitudes and latencies) to the click and LS CE-Chirp® stimuli within the same clinical session and between the two clinical sessions was calculated using an intra-class correlation coefficient analysis (ICC). Results: The results showed a significant correlation of the ABR findings (amplitude and latencies) to both stimuli within the same session and between the clinical sessions. The ICC values ranged from moderate to excellent. Conclusions: The ABR results from both the LS CE-Chirp® and click stimuli were consistent and reliable over the two clinical sessions suggesting that both stimuli can be used for neurological diagnoses with the same reliability.

Development of Eyes Inspection Questionnaire(EIQ) and Regression Analysis between EIQ Items and deficiency or excess patterns of Eyes Inspection (안진(眼診) 설문지 개발 및 안진(眼診) 설문의 허실(虛實) 연관성 연구)

  • Seo, Jae-Ho;Choi, Jin-Yong;Oh, Whan-Sup;Park, Young-Bae;Park, Young-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.2
    • /
    • pp.75-84
    • /
    • 2014
  • Objectives Eyes, one of visual inspection regions, present important clues to pathological patterns including deficiency and excess patterns to the clinicians. The purpose of this study was to develop Eyes Inspection Questionnaire (EIQ) and to examine which items among the EIQ were more predictive of clinicians' determination for the deficiency and excess patterns. Methods Nine questionnaire items for Visual Inspection of Eyes were extracted through the literature review. These items were presented to the 4 Korean medical doctors who are specialized in visual inspection to conduct the Delphi method. The Korean medical doctors were asked to rate the importance of each items for the corresponding Visual Inspection of Eyes, using a Likert 5-point scale(the 3 points of importance as a cut-off point). Then, out of 75 photographs submitted to the Society of HyungSang Medicine in 2009, 30 portrait pictures were selected as samples. The samples were copied to make 60 sample pictures, and then randomly assigned to 4 clinicians. The 4 clinicians evaluated the 60 samples for excess and deficiency of the eyes and were asked to check the 6 questionnaire items. The results were recorded as 5-points-scale, and their average and standard deviations were calculated. Intra- class reliability test and multi regression test were performed using SPSS 13. Results Intra-class correlation coefficient (ICC) was between 0.750 to 0.841 (P<0.05). Indices for visual inspection of the eyes were: endowment of the bone structure around the eyes; brightness of the eyes; upward deviation of the eyes; eye shapes; and definition of iris. 76.92% of deficiency symptom patterns and 86.42% of the excess symptom patterns matched the patterns predicted by the visual inspection of the eyes, according to the frequency analysis. According to the multiple regression analysis, were significantly related to the excessive symptoms, and to the deficiency symptoms. Conclusion This study is the first attempt of development for checklist of excess and deficiency of Visual Inspection of Eyes and quantitative measurement of excess and deficiency using the Visual Inspection of Eyes by the visual inspection experts. Still, additional studies are needed regarding the relationship visual inspection methods have with existing standards of diagnosis.

Preliminary Psychometric Properties of the Chinese Version of the Work-Related Quality of Life Scale-2 in the Nursing Profession

  • Lin, Shike;Chaiear, Naesinee;Khiewyoo, Jiraporn;Wu, Bin;Johns, Nutjaree Pratheepawanit
    • Safety and Health at Work
    • /
    • v.4 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • Objectives: As quality of work-life (QWL) among nurses affects both patient care and institutional standards, assessment regarding QWL for the profession is important. Work-related Quality of Life Scale (WRQOLS) is a reliable QWL assessment tool for the nursing profession. To develop a Chinese version of the WRQOLS-2 and to examine its psychometric properties as an instrument to assess QWL for the nursing profession in China. Methods: Forward and back translating procedures were used to develop the Chinese version of WRQOLS-2. Six nursing experts participated in content validity evaluation and 352 registered nurses (RNs) participated in the tests. After a two-week interval, 70 of the RNs were retested. Structural validity was examined by principal components analysis and the Cronbach's alphas calculated. The respective independent sample t-test and intra-class correlation coefficient were used to analyze known-group validity and test-retest reliability. Results: One item was rephrased for adaptation to Chinese organizational cultures. The content validity index of the scale was 0.98. Principal components analysis resulted in a seven-factor model, accounting for 62% of total variance, with Cronbach's alphas for subscales ranging from 0.71 to 0.88. Known-group validity was established in the assessment results of the participants in permanent employment vs. contract employment (t = 2.895, p < 0.01). Good test-retest reliability was observed (r = 0.88, p < 0.01). Conclusion: The translated Chinese version of the WRQOLS-2 has sufficient validity and reliability so that it can be used to evaluate the QWL among nurses in mainland China.