The Efficacy of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration in Mediastinal Staging of Non-Small Cell Lung Cancer in a University Hospital

  • Joo, Hye-Jin;Kim, Hyeong-Ryul;Oh, Yeon-Mok;Kim, Yong-Hee;Shim, Tae-Sun;Kim, Dong-Kwan;Park, Seung-Il;Kim, Woo-Sung;Kim, Dong-Soon;Choi, Chang-Min
    • Tuberculosis and Respiratory Diseases
    • /
    • 제71권3호
    • /
    • pp.180-187
    • /
    • 2011
  • Background: In mediastinal lymph node sampling in non-small cell lung cancer (NSCLC) it is important to determine the appropriate treatment as well as to predict an outcome. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a recently developed, accurate, safe technique in patients with NSCLC for sampling mediastinal lymph nodes. We sought to determine the usefulness of EBUS-TBNA in mediastinal staging with NSCLC considered to be operable. Methods: We retrospectively reviewed the records of 142 patients who underwent EBUS-TBNA for mediastinal staging in the Asan Medical Center, Korea from July 2008 to July 2010. If patients were in an operable state, they underwent subsequent surgical staging. Diagnoses based on biopsy results were compared with those based on surgical results. Results: We performed EBUS-TBNA in 184 mediastinal lymph nodes in 142 NSCLC patients. Almost all of the EBUS-TBNA samples were from the lower paratracheal (112, 60.9%) and subcarinal (57, 31.0%) lymph nodes. In 142 patients, 51 patients (35.9%) were confirmed with malignant invasion of the mediastinal lymph node by EBUS-TBNA and 91 (64.1%) patients were not confirmed. Among the 91 patients, 64 patients (70.3%) underwent surgical staging. 3 patients (4.7%) who were misdiagnosed by the EBUS-TBNA were confirmed by surgery. After Diagnostic sensitivity of EBUS-TBNA, the prediction of mediastinal metastatsis was 94.4% and specificity was 100%. The procedures were performed safely and no serious complications were observed. Conclusion: We demonstrated the high diagnostic value of EBUS-TBNA for mediastinal staging.

Comparison of ultrasound-guided subacromial corticosteroid and ozone (O2-O3) injections in the treatment of chronic rotator cuff tendinopathy: a randomized clinical trial

  • Merve Orucu Atar;Nurdan Korkmaz;Sefa Gumruk Aslan;Ozge Tezen;Sinem Uyar Koylu;Yasin Demir;Serdar Kesikburun
    • The Korean Journal of Pain
    • /
    • 제36권1호
    • /
    • pp.128-136
    • /
    • 2023
  • Background: The authors aimed to compare the effects of a one-time ultrasound (US)-guided subacromial corticosteroid injection and three-time ozone (O2-O3) injection in patients with chronic supraspinatus tendinopathy. Methods: Participants were randomly assigned to the corticosteroid group (n = 22) or ozone group (n = 22). Injections in both groups were administered into subacromial bursa with an US-guided in-plane posterolateral approach. Primary outcome measure was the change in the Western Ontario Rotator Cuff Index (WORC) score between baseline and 12-weeks post-injection. Secondary outcome measures included visual analog scale and Shoulder Pain and Disability Index scores. Assessments were recorded at baseline, and 4-weeks and 12-weeks post-injection. Results: Forty participants completed this study. Based on repeated measurement analysis of variance, a significant effect of time was found for all outcome measures in both groups. Both the groups showed clinically significant improvements in shoulder pain, quality of life, and function. Baseline, 4-week post-injection, and 12-week post-injection WORC scores (mean ± standard deviation) were 57.91 ± 18.97, 39.10 ± 20.50 and 37.22 ± 27.31 in the corticosteroid group, respectively and 69.03 ± 15.89, 39.11 ± 24.36, and 32.26 ± 24.58 in the ozone group, respectively. However, no significant group × time interaction was identified regarding all outcome measures. Conclusions: Three-time ozone injection was not superior to a one-time corticosteroid injection in patients with chronic supraspinatus tendinopathy. It might be as effective as corticosteroid injection at 4-weeks and 12-weeks post-injection in terms of relieving pain and improving quality of life and function.

대퇴동맥을 통한 시술 후 발생한 가성동맥류의 초음파 유도하 경피적 트롬빈 주입 치료 (Ultrasound-Guided Percutaneous Thrombin Injection of Femoral Artery Pseudoaneurysms Caused by Vascular Access)

  • 채승윤;박찬;김재규;김형욱;이병찬
    • 대한영상의학회지
    • /
    • 제82권3호
    • /
    • pp.589-599
    • /
    • 2021
  • 목적 대퇴동맥을 통한 시술 후 발생한 의인성 가성동맥류에 대한 초음파 유도하 경피적 트롬빈 주입 치료의 성공률과 합병증 발생률, 치료의 실패에 관련된 요인 등을 분석해 보고자 한다. 대상과 방법 2009년 3월부터 2019년 6월까지 대퇴동맥에 발생한 의인성 가성동맥류에 대하여 영상의학과에서 초음파 유도하 경피적 트롬빈 주입 치료를 받은 30명의 환자들을 후향적으로 분석하였다. 대퇴동맥의 가성동맥류는 초음파 또는 전산화단층촬영을 사용하여 진단하였으며, 환자와 병변의 특성에 대하여 분석하였다. 결과 환자들의 평균 나이는 67.8세였으며, 가성동맥류의 평균 직경은 20.88 mm (5~40 mm)였다. 첫 치료에서 20명의 환자에서 완전한 혈전형성을 보였으며(66.6%), 10명의 환자에서 부분적 혈전형성을 보였다(33.3%). 혈소판 수가 낮은 환자(< 130 k/µL)에서 부분적 혈전형성의 가능성이 유의하게 높았다. 모든 환자에서 시술 관련 합병증은 보이지 않았다. 결론 대퇴동맥의 의인성 가성동맥류에 대한 초음파 유도하 트롬빈 주입 치료는 안전하고 효과적인 우선적 치료 방법이다.

Assessing the Potential of Thermal Imaging in Recognition of Breast Cancer

  • Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8619-8623
    • /
    • 2016
  • Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.

Prostate Cancer Incidence in Turkey: An Epidemiological Study

  • Zorlu, Ferruh;Divrik, Rauf Taner;Eser, Sultan;Yorukoglu, Kutsal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권21호
    • /
    • pp.9125-9130
    • /
    • 2014
  • Background: This study aimed to determine the incidence of prostate cancer in Turkey in a population-based sample, and to determine clinical and pathological characteristics of the cases. Materials and Methods: All newly diagnosed prostate cancer patients were included in this national, multi-centered, prospective and non-interventional epidemiological registry study conducted in 12 cities representing the 12 regions of Turkey from July 2008 to June 2009. The population-based sample comprised 4,150 patients with a recent prostate cancer diagnosis. Results: Age-adjusted prostate cancer incidence rate was 35 cases per 100,000 in Turkey. At the time of diagnosis, median age was 68, median PSA level was 10.0 ng/mL. Digital rectal examination was abnormal in 36.2% of 3,218 tested cases. Most patients had urologic complaints. The main diagnostic method was transrectal ultrasound guided biopsy (87.8%). Gleason score was ${\leq}6$ in 49.1%, 7 in 27.8% and >7 in 20.6% of the cases. There was a statistically significant positive correlation between serum PSA level and Gleason score (p=0.000). The majority of patients (54.4%) had clinical stage T1c. Conclusions: This is the first population-based national data of incidence with the histopathological characteristics of prostate cancer in Turkey. Prostate cancer remains an important public health concern in Turkey with continual increase in the incidence and significant burden on healthcare resources.

Predictive factors associated with successful response to utrasound guided genicular radiofrequency ablation

  • Kose, Selin Guven;Kose, Halil Cihan;Celikel, Feyza;Akkaya, Omer Taylan
    • The Korean Journal of Pain
    • /
    • 제35권4호
    • /
    • pp.447-457
    • /
    • 2022
  • Background: Ultrasound-guided genicular nerve radiofrequency (RF) procedures are of interest in the management of chronic knee pain. A wide variety of demographic, clinical, and procedural characteristics can affect treatment success. This study aimed to determine predictive factors to provide superior treatment outcomes. Methods: The demographic, clinical, and technical data of patients who received genicular nerve RF for knee pain between September 2016 and September 2021 were evaluated. A positive outcome was defined as at least 50% pain relief on a pain score for at least 6 months. Logistic regression analysis was performed to determine the factors associated with a successful response to genicular RF. Results: Among 206 patients who underwent genicular RF, 62% of the patients reported successful outcomes at 6 months. In the multivariate model, targeting 5 nerves (odds ratio [OR], 6.184; 95% confidence interval [CI], 2.291-16.690; P < 0.001) was the most significant predictor of successful outcomes. Multivariable logistic regression analysis showed that prognostic genicular nerve block with a 50% cut-off value (OR, 2.109; 95% CI, 1.038-4.287; P = 0.039), no opioid use (OR, 2.753; 95% CI, 1.405-5.393; P = 0.003), and depression (OR, 0.297; 95% CI, 0.124-0.713; P = 0.007) were the predictive factors significantly associated with response to genicular RF. Conclusions: Clinical and technical factors associated with better treatment outcomes were ultimately targeting more nerves, performing prognostic block, no opioid use, and no depression. These results are expected to be considered when selecting patients for genicular RF.

Comparison of the efficacy of genicular nerve phenol neurolysis and radiofrequency ablation for pain management in patients with knee osteoarthritis

  • Gokhan Yildiz;Gevher Rabia Genc Perdecioglu;Damla Yuruk;Ezgi Can;Omer Taylan Akkaya
    • The Korean Journal of Pain
    • /
    • 제36권4호
    • /
    • pp.450-457
    • /
    • 2023
  • Background: Genicular nerve neurolysis with phenol and radiofrequency ablation (RFA) are two interventional techniques for treating chronic refractory knee osteoarthritis (KOA) pain. This study aimed to compare the efficacy and adverse effects of both techniques. Methods: Sixty-four patients responding to diagnostic blockade of the superior medial, superior lateral, and inferior medial genicular nerve under ultrasound guidance were randomly divided into two groups: Group P (2 mL phenol for each genicular nerve) and Group R (RFA 80℃ for 60 seconds for each genicular nerve). The numeric rating scale (NRS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were used to evaluate the effectiveness of the interventions. Results: RFA and phenol neurolysis of the genicular nerves provided effective analgesia within groups at 1 week, 1 month, and 3 months compared to baseline. There was no significant difference between the groups in terms of NRS and WOMAC scores at all measurement times. At the 3rd month follow-up, 50% or more pain relief was observed in 53.1% of patients in Group P and 50% of patients in Group R. The rate of transient paresthesia was 34.4% in Group P and 6.3% in Group R, and this was significantly higher in Group P. Conclusions: Neurolysis of the genicular nerves with both RFA and phenol is effective in the management of KOA pain. Phenol may be a good alternative to RFA. Further studies are needed on issues such as dose adjustment to prevent transient paresthesia response.

A comparison of analgesic efficacy and safety of clonidine and methylprednisolone as additives to 0.25% ropivacaine in stellate ganglion block for the treatment of complex regional pain syndrome: a prospective randomised single blind study

  • Sreyashi Naskar;Debesh Bhoi;Heena Garg;Maya Dehran;Anjan Trikha;Mohammed Tahir Ansari
    • The Korean Journal of Pain
    • /
    • 제36권2호
    • /
    • pp.216-229
    • /
    • 2023
  • Background: The role of the sympathetic nervous system appears to be central in causing pain in complex regional pain syndrome (CRPS). The stellate ganglion block (SGB) using additives with local anesthetics is an established treatment modality. However, literature is sparse in support of selective benefits of different additives for SGB. Hence, the authors aimed to compare the efficacy and safety of clonidine with methylprednisolone as additives to ropivacaine in the SGB for treatment of CRPS. Methods: A prospective randomized single blinded study (the investigator blinded to the study groups) was conducted among patients with CRPS-I of the upper limb, aged 18-70 years with American Society of Anaesthesiologists physical status I-III. Clonidine (15 ㎍) and methylprednisolone (40 mg) were compared as additives to 0.25% ropivacaine (5 mL) for SGB. After medical treatment for two weeks, patients in each of the two groups were given seven ultrasound guided SGBs on alternate days. Results: There was no significant difference between the two groups with respect to visual analogue scale score, edema, or overall patient satisfaction. After 1.5 months follow-up, however, the group that received methylprednisolone had better improvement in range of motion. No significant side effects were seen with either drug. Conclusions: The use of additives, both methylprednisolone and clonidine, is safe and effective for the SGB in CRPS. The significantly better improvement in joint mobility with methylprednisolone suggests that it should be considered promising as an additive to local anaesthetics when joint mobility is the concern.

Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis

  • Juil Park;Kichang Han;Joon Ho Kwon;Man-Deuk Kim;Jong Yun Won;Sungmo Moon;Gyoung Min Kim
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1241-1248
    • /
    • 2023
  • Objective: To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS). Materials and Methods: This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis. Results: Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%). All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1-36 months. No serious procedure-related adverse events were observed. Conclusion: Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.

Current Practices in Breast Magnetic Resonance Imaging: a Survey Involving the Korean Society of Breast Imaging

  • Yun, Bo La;Kim, Sun Mi;Jang, Mijung;Kang, Bong Joo;Cho, Nariya;Kim, Sung Hun;Koo, Hye Ryoung;Chae, Eun Young;Ko, Eun Sook;Han, Boo-Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권4호
    • /
    • pp.233-241
    • /
    • 2017
  • Purpose: To report on the current practices in breast magnetic resonance imaging (MRI) in Korea. Materials and Methods: We invited the 68 members of the Korean Society of Breast Imaging who were working in hospitals with available breast MRI to participate in a survey on how they performed and interpreted breast MRI. We asked one member from each hospital to respond to the survey. A total of 22 surveys from 22 hospitals were analyzed. Results: Out of 22 hospitals, 13 (59.1%) performed at least 300 breast MRI examinations per year, and 5 out of 22 (22.7%) performed > 1200 per year. Out of 31 machines, 14 (45.2%) machines were 1.5-T scanners and 17 (54.8%) were 3.0-T scanners. All hospitals did contrast-enhanced breast MRI. Full-time breast radiologists supervised the performance and interpreted breast MRI in 19 of 22 (86.4%) of hospitals. All hospitals used BI-RADS for MRI interpretation. For computer-aided detection (CAD), 13 (59.1%) hospitals sometimes or always use it and 9 (40.9%) hospitals did not use CAD. Two (9.1%) and twelve (54.5%) hospitals never and rarely interpreted breast MRI without correlating the mammography or ultrasound, respectively. The majority of respondents rarely (13/21, 61.9%) or never (5/21, 23.8%) interpreted breast MRI performed at an outside facility. Of the hospitals performing contrast-enhanced examinations, 15 of 22 (68.2%) did not perform MRI-guided interventional procedures. Conclusion: Breast MRI is extensively performed in Korea. The indication and practical patterns are diverse. The information from this survey would provide the basis for the development of Korean breast MRI practice guidelines.