• 제목/요약/키워드: Interventional Radiology

검색결과 225건 처리시간 0.023초

Ultrasonography-Guided Common Musculoskeletal Interventions from Head to Toe: Procedural Tips for General Radiologists

  • Roland White;Michael Croft;Stephen Bird;Matthew Sampson
    • Korean Journal of Radiology
    • /
    • 제22권12호
    • /
    • pp.2006-2016
    • /
    • 2021
  • The expanding scope of interventional musculoskeletal procedures has resulted in increased pressure on general radiologists. The confidence of general radiologists in performing ultrasound-guided musculoskeletal procedures varies with their clinical exposure. This didactic review provides a methodologically and clinically oriented approach to enhancing user understanding and confidence in performing ultrasound-guided musculoskeletal procedures. The body of the text is accompanied by figures depicting the procedural approach, injection site, and labeled ultrasonography images. This paper aims to provide a teaching and bedside aid for education on and the execution of musculoskeletal procedures to ensure the provision of quality health care.

Successful Management with Glue Injection of Arterial Rupture Seen during Embolization of an Arteriovenous Malformation Using a Flow-Directed Catheter: A Case Report

  • Jong Won Hong;Seung Kug Baik;Mi Jung Shin;Han Yong Choi;Bong Gi Kim
    • Korean Journal of Radiology
    • /
    • 제1권4호
    • /
    • pp.208-211
    • /
    • 2000
  • We present a case in which an arterial rupture occurring during embolization of an arteriovenous malformation of the left occipital lobe with a flow-directed microcatheter, was successfully sealed with a small amount of glue. We navigated a 1.8-Fr Magic catheter through the posterior cerebral artery, and during superselective test injection, extravasation was observed at the parieto-occipital branch. The catheter was not removed and the perforation site was successfully sealed with a small amount of glue injected through the same catheter. Prompt recognition and closure of the perforation site is essential for good prognosis.

  • PDF

Ultrasonography Findings of the Carpal Tunnel after Endoscopic Carpal Tunnel Release for Carpal Tunnel Syndrome

  • Alex Wing Hung Ng;James Francis Griffith;Carita Tsoi;Raymond Chun Wing Fong;Michael Chu Kay Mak;Wing Lim Tse;Pak Cheong Ho
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1132-1141
    • /
    • 2021
  • Objective: To investigate changes in the median nerve, retinaculum, and carpal tunnel on ultrasound after successful endoscopic carpal tunnel release (ECTR). Materials and Methods: This prospective study involved 37 wrists in 35 patients (5 male, 30 female; mean age ± standard deviation [SD], 56.9 ± 6.7 years) with primary carpal tunnel syndrome (CTS). An in-house developed scoring system (0-3) was used to gauge the clinical improvement after ECTR. Ultrasound was performed before ECTR, and at 1, 3, and 12 months post-ECTR. Changes in the median nerve, flexor retinaculum, and carpal tunnel morphology on ultrasound after ECTR were analyzed. Ultrasound parameters for different clinical improvement groups were compared. Results: All patients improved clinically after ECTR. The average clinical improvement score ± SD at 12 months post-ECTR was 2.2 ± 0.7. The median nerve cross-sectional area proximal and distal to the tunnel decreased at all time intervals post-ECTR but remained swollen compared to normal values. Serial changes in the median nerve caliber and retinacular bowing after ECTR were more pronounced at the tunnel outlet than at the tunnel inlet. The flexor retinaculum had reformed in 25 (68%) of 37 wrists after 12 months. Conclusion: Postoperative changes in median nerve and retinaculum parameters were most pronounced at the tunnel outlet. Even in patients with clinical improvement after ECTR, nearly all ultrasound parameters remain abnormal at one year post-ECTR. These ultrasound parameters should not necessarily be relied upon to diagnose persistent CTS after ECTR.

Photon-Counting Computed Tomography: Experience in Musculoskeletal Imaging

  • Jan-Peter Grunz;Henner Huflage
    • Korean Journal of Radiology
    • /
    • 제25권7호
    • /
    • pp.662-672
    • /
    • 2024
  • Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there. PCCT facilitates an unprecedented combination of ultra-high-resolution imaging without dose penalty or field-of-view restrictions, detector-based elimination of electronic noise, and ubiquitous multi-energy spectral information. Considering the high demands of orthopedic imaging for the visualization of minuscule details while simultaneously covering large portions of skeletal and soft tissue anatomy, no subspecialty may benefit more from this novel detector technology than musculoskeletal radiology. Deeply rooted in experimental and clinical research, this review article aims to provide an introduction to the cosmos of PCCT, explain its technical basics, and highlight the most promising applications for patient care, while also mentioning current limitations that need to be overcome.

인터벤션시술 진단참고수준 평가 (Evaluation of Diagnostic Reference Level in Interventional Procedures)

  • 강병삼;박형신
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.451-457
    • /
    • 2021
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure and patient radiation exposure is also increasing accordingly. In this study, we evaluated the patient dose of major interventional procedures nationwide and we established our Korean database. With these results, we tried to suggest the reference dose level for major interventional procedures. We evaluated patent dose data in the field of interventional radiology from foreign countries. Measurement of radiation dose exposure for 11 major interventional procedures was conducted using embedded DAP meters in 10,006 patients from 47 hospitals, and reference level of each interventional procedure was suggested. The DRLs of each intervenional procedure are as follows: TACE 206(Gy·cm2), AVF 12(Gy·cm2), LE intervention 43(Gy·cm2), TFCA 122(Gy·cm2), Cerebral aneurysm coil embolization 214(Gy·cm2), PTBD 22(Gy·cm2), Biliary stent 60(Gy·cm2), PCN 7(Gy·cm2), Hickman catheter 2.1(Gy·cm2), Chemoport 1.4(Gy·cm2), BAE 104(Gy·cm2). Compared with the previously established DRL in 2012, the radiation dose decreased in all 10 interventional procedures. In the future, continuous publicity and education on the radiation dose reduction will be needed.

간 외상과 그 합병증의 영상 소견과 인터벤션 치료 (Imaging Features and Interventional Treatment for Liver Injuries and Their Complications)

  • 유성현;박소현;김종우;김정호;황정한;박수영;이기현
    • 대한영상의학회지
    • /
    • 제82권4호
    • /
    • pp.851-861
    • /
    • 2021
  • 간 외상은 복부 둔상에서 흔하다. 조영증강 전산화단층촬영을 통해 간 외상을 빠르게 진단하고 평가할 수 있다. 간 외상의 치료 전략은 수술적 방법에서 점차 비수술적 방법으로 바뀌어 왔는데, 간 외상뿐 아니라 그 합병증에 대한 보완적 치료 방법으로 인터벤션이 각광받고 있다. 이 종설에서는 간 외상에서 보일 수 있는 주요 영상 소견과, 치료에 있어서 인터벤션의 역할에 대해 알아보고자 한다.

갑상선 영상의학 진료: 갑상선 결절 환자의 진단과 중재적 치료 (Thyroid Radiology Practice: Diagnosis and Interventional Treatment of Patients with Thyroid Nodules)

  • 백정환;나동규
    • 대한영상의학회지
    • /
    • 제81권3호
    • /
    • pp.530-548
    • /
    • 2020
  • 갑상선 영상의학 진료란 갑상선 질환 환자를 영상의학적 방법을 활용하여 질병 진단과 중재적 치료를 하는 의료 행위로 정의될 수 있으며 주요 진료 대상은 갑상선 결절 질환 환자들이다. 갑상선 결절의 진단은 일차적으로 초음파 영상진단과 생검에 의해서 이루어지고 결절의 치료는 비수술적 중재적 치료와 갑상선절제술이다. 갑상선 낭종 혹은 낭성우세 양성 결절에서는 에탄올절제술이 일차적 치료법이고 고주파절제술은 고형 혹은 고형우세 양성 결절과 갑상선 재발암 치료에 적용되고 있다. 갑상선 영상의학 진료는 갑상선 결절 질환 환자의 진단 및 비수술적 치료의 대부분을 담당하는 중요한 임상적 역할을 가지고 있으며, 적절한 환자 진료를 위해서는 표준적 진료 지침에 근거하여 진료가 수행되어야 한다. 환자에게 최적의 갑상선 영상의학 진료를 제공하기 위해서는 영상의학과 외래에서 환자를 진료하는 것이 바람직하며 외래 중심의 갑상선 영상의학 진료를 확대하도록 함께 노력해야 할 시점이다.

인터벤션 시술 시 환자의 선량감소를 위한 3D 프린팅 재료의 적용성 평가 (Feasibility of the 3D Printing Materials for Radiation Dose Reduction in Interventional Radiology)

  • 조용인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.169-176
    • /
    • 2020
  • Interventional radiology is performed under real-time fluoroscopy, and patients are exposed to a wide range of exposures for a long period of time depending on the examination and procedure. However, studies on radiation protection for patients during an intervention are insufficient. This study aims to evaluate the doses exposed during the intervention and the applicability of 3D printing materials. The organ dose for each intervention site was evaluated using a monte carlo simulatio. Also, the dose reduction effect of the critical organs was calculated when using a shielding device using 3D printing materials. As a result, the organ dose distribution for each intervention site showed a lower dose distribution for organs located far from the x-ray tube. It was analyzed that the influence of scattered rays was higher in the superficial organs of the back of the human body where x-rays were incident. The dose reduction effect on the critical organ using the 3D printing shield showed the highest testis among the gonads, and in the case of other organs, the dose reduction effect gradually decreased in the order of the eye, thyroid, breast, and ovary. Accordingly, it is judged that the 3D printed shield will be sufficiently usable as a shielding device for the radiation protection of critical organs.