• Title/Summary/Keyword: Intertrochanteric fractures

Search Result 24, Processing Time 0.025 seconds

Changes In Mechanical Strength of Compression HIP Screws in Relation to Design Variations - A Biomechanical Analysis

  • Moon S. J.;Lee H. S.;Jun S. C.;Jung T. G.;Ahn S. Y.;Lee H.;Lee S. J.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.123-127
    • /
    • 2005
  • Compression Hip Screw (CHS) is one of the most widely-used prostheses for the treatment of intertrochanteric fractures because of its strong fixation capability. Fractures at the neck and screw holes are frequently noted as some of its clinical drawbacks, which warrant more in-depth biomechanical analysis on its design variables. The purpose of this study was to evaluate changes in the strength with respect to the changes in design such as the plate thickness and the number of screw holes. Both mechanical test and FEM analysis were used to systematically investigate the sensitivities of the above-mentioned design variables. For the first part of the mechanical test, CHS (n=20) were tested until failure. The CHS specimens were classified into four groups: Group Ⅰ was the control group with the neck thickness of 6-㎜ and 5 screw holes on the side plate, Group Ⅱ 6-㎜ thick and 8 holes, Group Ⅲ 7.5-㎜ thick and 5 holes, and Group Ⅳ 7.5-㎜ thick and 8 holes. Then, the fatigue test was done for each group by imparting 50% and 75% of the failure loads for one million cycles. For the FEM analysis, FE models were made for each group. Appropriate loading and boundary conditions were applied based on the failure test results. Stresses were assessed. Mechanical test results indicated that the failure strength increased dramatically by 80% with thicker plate. However, the strength remained unchanged or decreased slightly despite the increase in number of holes. These results indicated the higher sensitivity of plate thickness to the implant strength. No fatigue failures were observed which suggested the implant could withstand at least one million cycles of fatigue load regardless of the design changes. Our FEM results also supported the above results by showing a similar trend in stress as those of mechanical test. In summary, our biomechanical results were able to show that plate thickness could be a more important variable in design for reinforcing the strength of CHS than the number of screw holes.

Surgical Treatment of Metastatic Bone Tumor in Extremity (사지에서 전이성 골종양의 수술적 치료)

  • Lee, Han-Koo;Lee, Sang-Hoon;Baek, Goo-Hyun;Lee, Chang-Seop
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.1
    • /
    • pp.45-51
    • /
    • 1995
  • The incidence of metastatic bony lesion has been increased recently, with the advanced therapeutic modalities of malignant tumors. The purpose of this study was to evaluate the effectiveness of surgical treatment in impending or established pathologic fractures due to metastasis in extremity. From 1981 to 1992, thirty two patients who had established or impending pathologic fractures in extremity had been treated surgically. The locations of metastasis, were lower extremity in 24 cases(femsral head and neck;5, intertrochanteric;7, subtrochanteric;8, femoral shaft;4) and upper extremity in 8 cases(proximal humerus;2, humoral shaft;6). The method of surgery was excision of tumor mass and rigid internal fixation to allow immediate mobilization, except 2 cases of amputation. The results were analysed by two criteria. The first was the grade of performance status that was made by modification of Functional Classification of New York Heart Association. The second was the degree of pain relief. The performance status was improved at least one grade in all patients and the mean improvement was 1.7 grades. The satisfactory pain relief was achieved in 81% of patients. Postoperatively, most of the patients had only slight to moderate limitation of physical activities and they became comfortable at rest and ordinary activities. The solitary metastatic lesions showed better pain relief(92%) than multiple metastasis(75%). The curative surgery was done in 3 cases, and they showed more than 24 months of disease-free survival.

  • PDF

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

Incidence of Deep Vein Thrombosis before Hip Fracture Surgery Diagnosed by Color Doppler Sonography Surveillance (고관절 주위 골절환자에서 술 전 색 도플러 초음파를 이용하여 진단한 심부 정맥 혈전의 빈도)

  • Jung, Jae-Hoon;Lee, Kyung-Jae;Min, Byung-Woo;Son, Eun-Seok;Koo, Tae-Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.98-104
    • /
    • 2014
  • Purpose: To evaluate the incidence of deep vein thrombosis (DVT) before hip fracture by duplex color Doppler ultrasonography. Materials and Methods: From June 2013 to May 2014, 27 patients who had agreed to perform color Doppler ultrasonography before hip fracture surgery were evaluated for the incidence of DVT. Patients who had history of DVT were excluded. Five patients were men and 19 patients were women. The mean age was 74.3 years old (41-87). There were 15 cases of femoral neck fracture, 11 cases of intertrochanteric fractures and one case of acetabular fracture. Surgical intervention underwent within 48 hours from admission and duplex color Doppler ultrasonography was carried out at the day of admission. Results: DVT occurred in six cases (22.2%). Four cases (14.8%) occurred in proximal deep vein and two cases (7.4%) occurred in distal deep vein. The mean period of immobilization was longer in patients who had DVT. But there was no significant difference. The mean age was 79 years old (75-87) in patients who had DVT and 72 years old (65-86) in patients who had not. There was significant difference (p=0.038). Conclusion: The incidence of DVT which was diagnosed by duplex color Doppler ultrasonography before hip fracture surgery was relatively high (22.2%). So it is necessary to undergo duplex color Doppler ultrasonography more aggressively to rule out DVT before hip fracture surgery.

  • PDF