• Title/Summary/Keyword: Internet server

Search Result 1,960, Processing Time 0.025 seconds

Remote Control of a Mobile Robot using Embedded web server (Embedded web server를 이용한 이동로봇의 원격제어)

  • Park, Jeong-Hoon;Kim, Jin-Geun;Kang, Moon-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2693-2695
    • /
    • 2005
  • In this paper, we developed a more efficient system for the remote control and monitoring of a wheeled mobile robot using internet without spatial limitation. The hardware configuration of the remote control system for a wheeled mobile robot includes a client PC executed on the remote site, a embedded web-server and a mobile robot with many measuring equipments. The communication between a client PC and a embedded web-server is implemented through internet. And the Bluetooth module is used for connecting a embedded web-server and a mobile robot. A GUI program has been developed by using JavaScript in order to easily control a mobile robot on a client PC.

  • PDF

Implementation of Monitoring and Control System for Fire Engine Pump using the AJAX (AJAX를 이용한 소방엔진펌프의 모니터링과 제어 시스템 구현)

  • Yang, Oh;Lee, Heon-Guk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.40-45
    • /
    • 2016
  • In this paper, the fire engine pump is controlled and monitored by the AJAX (Asynchronous Javascript and Xml) in the web server. The embedded system with built-in system having a processor and a memory of high performance occurs many problems in transmitting the large amount of data in real time through the web server. The AJAX is different from HTML (Hyper Text Makeup Language) with java script technology and can make RIA (Rich Internet Application). It process the necessary data by using asynchronous and it take advantage of usefulness, accessibility, a fast response time. Using AJAX can build up web server with real time and monitoring that fire engine pump status, check processing pump memory in the event of fire, also remotely monitors can do. The web server system can control the fire engine pump as like the black box. The experimental results show the effectiveness and commercialize possibility.

A Two-Way Communication Method for Smart Phone Integrated with Pager (무선호출기를 갖는 다기능 전화기의 양방향 통신방법)

  • 유장희;박태준
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.487-490
    • /
    • 1998
  • In this paper, we describe a method for two-way communication service for smart phone integrated with pager which receive various kinds of Internet service information and pushes this information into smart phone to make it available for Internet assess. In this method, the server can push the status data of message boxes into the smart phone and it makes connection to the server automatically. The proposed method will make it possible to manage and excange the information and resources in an efficient manner during idle time, and will provide the potential capabilities of developing a variety of new Internet services for the system.

  • PDF

Development of a remote control camera system based on internet (인터넷기반의 원격제어 카메라 시스템 개발)

  • 최기훈;김영탁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.504-506
    • /
    • 1997
  • CCD camera is usually used for monitoring device. In most cases, he monitoring is performed from long distance. In this study, a camera system controlled through internet is developed. Using the system, not only we can get image information in real time but also we can control the orientation of the camera from long distance. Furthermore wireless communication is carried out between the camera and the server computer for verity of the application.

  • PDF

Analysis on the Performance Elements of Web Server Cluster Systems (웹서버 클러스터 시스템의 성능 요소 분석)

  • Park, Jin-Won
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.3
    • /
    • pp.91-98
    • /
    • 2010
  • This paper is on the research result for analyzing the performance of GLORY(GLobal Resource management sYstem) used for Web Server Cluster system, which was developed at ETRI(Electronic and Telecommunication Research Institute). The paper includes the definition of Web Server Cluster System, the characteristics of the system, user oriented system performance, current performance enhancement methods, computer simulation model for GLORY and its experimental results for the performance of GLORY. GLORY is composed of 2048~1,000,000 units of PCs, and is used for Internet servers. From the results of the simulation experiments, we notice that GLORY has enough capacity to fully serve the appropriate level of Internet services. Also, the results show that Web server service time is longer than that for network transmission time but requires more DNS than expected, and that 100Mbps LAN is good enough for directly connecting Internet to the Web servers while not affecting the total system performance.

An Extended Multi-Server-Based User Authentication and Key Agreement Scheme with User Anonymity

  • Li, Chun-Ta;Lee, Cheng-Chi;Weng, Chi-Yao;Fan, Chun-I
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.1
    • /
    • pp.119-131
    • /
    • 2013
  • With the explosive growth of computer networks, many remote service providing servers and multi-server network architecture are provided and it is extremely inconvenient for users to remember numerous different identities and passwords. Therefore, it is important to provide a mechanism for a remote user to use single identity and password to access multi-server network architecture without repetitive registration and various multi-server authentication schemes have been proposed in recent years. Recently, Tsaur et al. proposed an efficient and secure smart card based user authentication and key agreement scheme for multi-server environments. They claimed that their scheme satisfies all of the requirements needed for achieving secure password authentication in multi-server environments and gives the formal proof on the execution of the proposed authenticated key agreement scheme. However, we find that Tsaur et al.'s scheme is still vulnerable to impersonation attack and many logged-in users' attack. We propose an extended scheme that not only removes the aforementioned weaknesses on their scheme but also achieves user anonymity for hiding login user's real identity. Compared with other previous related schemes, our proposed scheme keeps the efficiency and security and is more suitable for the practical applications.

An Expanded Patching Technique using Four Types of Streams for True VoD Services

  • Ha, Sook-Jeong;Bae, Ihn-Han;Kim, Jin-Gyu;Park, Young-Ho;Oh, Sun-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.3 no.5
    • /
    • pp.444-460
    • /
    • 2009
  • In this paper, we propose an expanded patching technique in order to reduce the server network bandwidth requirements to support true VoD services in VoD Systems. Double Patching, which is a typical multicast technique, ensures that a long patching stream delivers not only essential video data for the current client but also extra video data for future clients. Since the extra data may include useless data, it results in server network bandwidth wastage. In order to prevent a server from transmitting useless data, the proposed patching technique uses a new kind of stream called a linking stream. A linking stream is transmitted to clients that have received short patching streams, and it plays a linking role between a patching stream and a regular stream. The linking stream enables a server to avoid transmitting unnecessary data delivered by a long patching stream in Double Patching, so the server never wastes its network bandwidth. Mathematical analysis shows that the proposed technique requires less server network bandwidth to support true VoD services than Double Patching. Moreover, simulation results show that it has better average service latency and client defection rate compared with Double Patching.

A new model and testing verification for evaluating the carbon efficiency of server

  • Liang Guo;Yue Wang;Yixing Zhang;Caihong Zhou;Kexin Xu;Shaopeng Wang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.10
    • /
    • pp.2682-2700
    • /
    • 2023
  • To cope with the risks of climate change and promote the realization of carbon peaking and carbon neutrality, this paper first comprehensively considers the policy background, technical trends and carbon reduction paths of energy conservation and emission reduction in data center server industry. Second, we propose a computing power carbon efficiency of data center server, and constructs the carbon emission per performance of server (CEPS) model. According to the model, this paper selects the mainstream data center servers for testing. The result shows that with the improvement of server performance, the total carbon emissions are rising. However, the speed of performance improvement is faster than that of carbon emission, hence the relative carbon emission per unit computing power shows a continuous decreasing trend. Moreover, there are some differences between different products, and it is calculated that the carbon emission per unit performance is 20-60KG when the service life of the server is five years.

A Consolidated Wireless Internet Proxy Server Cluster Architecture (통합형 무선 인터넷 프록시 서버 클러스터 구조)

  • Kwak Hu-Keun;Chung Kyu-Sik
    • The KIPS Transactions:PartA
    • /
    • v.13A no.3 s.100
    • /
    • pp.231-240
    • /
    • 2006
  • In this paper, wireless internet proxy server clusters are used for the wireless internet because their caching, distillation, and clustering functions are helpful to overcome the limitations and needs of the wireless internet. TranSend was proposed as a clustering based wireless internet proxy server but it has disadvantages; 1) its scalability is difficult to achieve because there is no systematic way to do it and 2) its structure is complex because of the inefficient communication structure among modules. In our former research, we proposed the CD-A structure which can be scalable in a systematic way but it also has disadvantages; its communication structure among modules is partly complex. In this paper, we proposed a consolidated scheme which has a systematic scalability and an efficient communication structure among modules. We performed experiments using 16 PCs and experimental results show 196% and 40% performance improvement of the proposed system compared to the TranSend and the CD-A system, respectively.

A study on IoT platform for private electrical facilities management (수용가 전력설비 관리를 위한 사물인터넷 플랫폼 연구)

  • Jang, Kyung-Bae
    • Journal of Internet of Things and Convergence
    • /
    • v.5 no.2
    • /
    • pp.103-110
    • /
    • 2019
  • In this paper, we suggested how the Internet of Things (IoT) technology could be applied to an internet platform that is used for managing the customer's power grid efficiently. For an internet platform with efficient management, analysis is done by several sections; communication method, and its protocol, and also security element. From this analysis, with currently used sensors, we have presented a development method for the sensor to server data reliable communication solution and data management server with a security solution. Moreover, this paper suggests a communication module that could be used for a power grid management platform, protocol and security algorithm and also a way to build a server for managing those systems and modules.