• Title/Summary/Keyword: Internal voltage

Search Result 659, Processing Time 0.033 seconds

The Reaction of Internal Electrodes with Bi$_2$O$_3$ in Multilayer ZnO Varistor (적층형 ZnO바리스터의 내부전극과 Bi$_2$O$_3$ 와의 반응)

  • Kim, Young-Jung;Kim, Hwan;Hong, Kook-Sun;Lee, Jong-Kook
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.11
    • /
    • pp.1121-1129
    • /
    • 1998
  • Reactions between Ag-Pd internal electrode materials and{{{{ { {Bi }_{2 }O }_{3 } }} in multilayer chip varistor were in-vestigated. For more than 1 mol%{{{{ { {Bi }_{2 }O }_{3 } }} in varistor composition internal electrode structure was destroyed due to the reaction between internal electrode and{{{{ { {Bi }_{2 }O }_{3 } }} But for typical varistor compositions (below 1 mol% of{{{{ { {Bi }_{2 }O }_{3 } }} content) microstructural changes around the internal electrode were not observed. However SEM-EDS and TEM-EDS analysis showed the uneven distribution of{{{{ { {Bi }_{2 }O }_{3 } }} in the internal electrode which was due to the migration of{{{{ { {Bi }_{2 }O }_{3 } }} to the electorde during sintering. As a results the nonlinear coefficient of multilayer varistor showed very large distribution as well as the breakdown voltage.

  • PDF

Design of MYNAMIC CMOS ARRAY LOGIC (DYNAMIC CMOS ARRAY LOGIC의 설계)

  • 한석붕;임인칠
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.10
    • /
    • pp.1606-1616
    • /
    • 1989
  • In this paper, the design of DYNAMIC CMOS ARRAY LOGIC which has both advantages of dynamic CMOS and array logic circuits is proposed. The major components of DYNAMIC CMOS ARRAY LOGIC are two-stage dunamic CMOS circuits and an internal clock generator. The function block of dynamic CMOS circuits is realized as a parallel interconnection of NMOS transistors. Therefore the operating speed of DYNAMIC CMOS ARRAY LOGIC is much faster than the one of the conventional dynamic CMOS PLAs and static CMOS PLA. Also, the charge redistribution problem by internl delay is solved. The internal clock generator generates four internal clocks that drive all the dynamic CMOS circuits. During evaluation, two clocks of them are delayed as compared with others. Therefore the race problem is completoly eliminated. The internal clock generator also prevents the reduction of circuit output voltage and noise margin due to leakage current and charge coupling without any penalty in circuit operating speed or chip area utilization.

  • PDF

A Study on the Fault Analysis of the Voltage Controller for the Combat Vehicle Generator (전투차량 발전기용 전압조정기 내열성 향상을 위한 고장분석 연구)

  • Ryu, Jeong-Min;Lee, Yong-Jun;Son, Kwonil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.386-393
    • /
    • 2019
  • In this study, we investigated the cause of a voltage controller failure that occurred in the operation of a combat vehicle and attempted to establish a solution for the failure. The failure in the voltage controller was found to be related to thermal resistance, which could be identified by disassembly analysis and a high temperature operation test. Especially, in the disassembly analysis, there was damage caused by high temperature such as soot on the molding material and cracking of the resisters. In addition, in the high temperature operation test, the test results show that the internal temperature of the voltage controller was relatively higher than the external temperature. This means that the voltage controller failure could be attributed to the excessive heat and insufficient thermal resistance. In order to improve the thermal resistance of the voltage controller, several designs with changing circuits and structures were devised. Improvement of thermal resistance was verified by measuring reduction of internal temperatures in the high temperature comparison test.

Development of Constant Output Power Supply System for Ozonizer (오존발생장치용 정출력 전원장치의 개발)

  • Woo, Jung-In;Woo, Sung-Hoon;Roh, In-Bae;Park, Jee-Ho;Kim, Dong-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.113-121
    • /
    • 2005
  • In this paper, a constant output power supply system for ozonizer is proposed to remove the noise of ozonizer and control the output of ozonizer using feedback control. The proposed system is based on the rouble control loop such as the outer voltage control loop and inner current control loop. In the proposed system overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the experimental results.

Permeability properties of skeletal muscle ATP-sensitive K+ channels reconstituted into planar lipid bilayer (평지방막에 융합된 골격근의 single ATP-sensitive K+ channel의 이온투과성에 대한 연구)

  • Ryu, Pan-dong
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.543-553
    • /
    • 1992
  • Properties of unitary ATP-sensitive $K^+$ channels were studied using planar lipid bilayer technique. Vesicles were prepared from bullfrog (Rana catesbeiana) skeletal muscle. ATP-sensitive $K^+$ (K (ATP)) channels were identified by their unitary conductance and sensitivity to ATP. In the symmetrical solution containing 200mM KCI, 10mM Hepes, 1mM EGTA and pH 7.2, single K (ATP) channels showed a linear current-voltage relations with slight inward rectification. Slope conductance at reversal potential was $60.1{\pm}0.43$ pS(n=3)). Micromolar ATP reversibly inhibited the channel activity when applied to the cytoplasmic side. In the range of -50~+50 mV, the channel activity was not voltage-dependent, but the channel gating within a burst was more frequent at negative voltage range. Varying the concentrations of external/internal KCl(mM) to 40/200, 200/200, 200/100 and 200/40 shifted reversal potentials to $-30.8{\pm}2.9$(n=3), $-1.1{\pm}2.7$(n=3), 10.5 and 30.6(mV), respecrivety. These reversal potentials were close to the expected values by the Nernst equation, indicating nearly ideal selectivity for $K^+$ over $Cl^-$. Under bi-ionic conditions of 200mM external test ions and 200mM internal $K^+$, the reversal potentials for each test ion/K pair were measured. The measured reversal potentials were used for the calculation of the releative permeability of alkali cations to $K^+$ ions using the Goldman-Hodgkin-Katz equation. The permeability sequence of 5 cations relative to $K^+$ was $K^+$(1), $Rb^+$(0.49), $Cs^+$(0.27), $Na^+$(0.027) and $Li^+$(0.021). This sequence was recognized as Eisenman's selectivity sequence IV. In addition, modelling the permeation of $K^+$ ion through ATP-sensitive $K^+$ channel revealed that a 3-barrier 2-site multiple occupancy model can reasonably predict the observed current-voltage relations.

  • PDF

A Study on the Fabrication and Simulation Analysis of AF-SMES System considering Internal Fault Condition (내부고장을 고려한 AF-SMES 시스템의 시뮬레이션 해석 및 제작에 관한 연구)

  • Kim, A-Rong;Kim, Jae-Ho;Kim, Hae-Jong;Kim, Seok-Ho;Seong, Ki-Chul;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1203-1204
    • /
    • 2006
  • Recently, utility network is getting more and more complicated and huge. In addition to, demands of power conversion devices which have non-linear switching devices are getting more and more increased. Consequently, according to the non-linear power semiconductor devices, current harmonics are unavoidable. Those current harmonics flow back to utility network and become one of the reasons which make the voltage distortion. On the other hands, voltage sag from sudden increasing loads is also one of the terrible problems inside of utility network. In order to compensate the current harmonics and voltage sag problem, AF(Active Filter) systems could be a good solution method and SMES(Superconducting Magnetic Energy Storage) system is a very good promising source due to the high response time of charge and discharge. Therefore, the combined system of AF and SMES is a wonderful device to compensate both harmonics current and voltage sag. However, unfortunately SMES needs a superconducting magnetic coil. Because of the introduction of superconducting magnetic coil, quench problem caused by unexpected reasons is always existed. In case of discharge operation, quench is a significantly harmful factor according as it decreases the energy capacity of SMES. Therefore, this paper presents a decision method of the specification of the AF-SMES system considering internal fault condition. Especially, authors analyzed the change of the original energy capacity of SMES regarding to the size of resistance caused by quench of superconducting magnetic coil. Finally, based on this simulation, authors manufactured actual Active Filter System using DSP.

  • PDF

Effect of pH on the ATP-sensitive $K^+$ Channel in Aortic Smooth Muscle Cells from Rats

  • Kim, Se-Hoon;Kim, Il-Su;Kim, Hoe-Suk;Jeon, Byeong-Hwa;Chang, Seok-Jong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.5
    • /
    • pp.555-563
    • /
    • 1997
  • The effects of pH on $K^+$ currents were investigated in single smooth muscle cells isolated from the thoracic aorta of Wistar-Kyoto rats. Whole-cell $K^+$ currents were recorded in the conventional configuration of the voltage-clamp technique. Pinacidil (10uM) activated the whole-cell current and the pinacidil-activated current was completely inhibited by glibenclamide (10uM) , an inhibitor of ATP-sensitive $K^+$ channel ($K_{ATP}$ channel). Pinacidil-activated current was reversed at near the $K^+$ equilibrium potential. This current was time- and voltage-independent and reduced by elevating intracellular ATP. Pinacidil-activated current was reduced by lowering the external pH. However, alteration of internal pH has controversial effects on pinacidil-activated current. When the single cell was dialyzed with 0.1 mM ATP, alteration of internal pH had no effect on pinacidil-activated $K^+$ current. In the contrast, when the single cell was dialyzed with 3 mM ATP, pinacidil-activated current was increased by lowering internal pH. Our results suggest that $K^+$ channel activated by pinacidil may be $K_{ATP}$ channel and internal $H^+$ may reduce the inhibitory effect of ATP on $K_{ATP}$ channel.

  • PDF

A New Three Winding Coupled Inductor-Assisted High Frequency Boost Chopper Type DC-DC Power Converter with a High Voltage Conversion Ratio

  • Ahmed Tarek;Nagai Shinichiro;Hiraki Eiji;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.99-103
    • /
    • 2005
  • In this paper, a novel circuit topology of a three-winding coupling inductor-assisting a high-frequency PWM boost chopper type DC-DC power converter with a high boost voltage conversion ratio and low switch voltage stress is proposed for the new energy interfaced DC power conditioner in solar photovoltaic and fuel cell generation systems. The operating principle in a steady state is described by using its equivalent circuits under the practical condition of energy processing of a lossless capacitive snubber. The newly-proposed power MOSFET boost chopper type DC-DC power converter with the three-winding coupled inductor type transformer and a single lossless capacitor snubber is built and tested for an output power of 500W. Utilizing the lower voltage and internal resistance power MOSFET switch in the proposed PWM boost chopper type DC-DC power converter can reduce the conduction losses of the active power switch compared to the conventional model. Therefore, the total actual power conversion efficiency under a condition of the nominal rated output power is estimated to be 81.1 %, which is 3.7% higher than the conventional PWM boost chopper DC power conversion circuit topology.

Parameter Measurement Method for Super Capacitor Failure Diagnosis and Application of Voltage Sag Compensation System Using Super Capacitor (수퍼 커패시터의 고장진단을 위한 파라미터의 측정기법과 순시전압강하 보상장치에의 응용사례)

  • Shon, Jin-Geun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.173-179
    • /
    • 2009
  • Recently, the super capacitor(EDLC) which has drawn attention as a new energy storage element has a lot of advantage such as no maintenance, long lifetime and quick charge/discharge characteristics with large current. The objective of this paper is propose a parameter measurement method to detect the changes in equivalent series resistor (ESR) and the capacitance value of a super capacitor in order to analysis the internal characteristic and worn-out state of a super capacitor. For proposed method, only the capacitor voltage measurement using simple analog switch is required. In addition, experimental results of voltage sag compensation system in order to compensate the input voltage drop during short-term power interruption adopted super capacitor are presented.

  • PDF

Evaluation of Reliability on the 6.6kV Class Ceramic Coupler for On-line Partial Discharge Measurement in Winding Machines (권선형기기 On-line 부분방전 측정용 6-6kV급 Ceramic Coupler의 신뢰성 평가)

  • Kang Dong-Sik;Kim Yong-Joo;Yun Youn-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.